Related papers: Single-reference high-precision mass measurement w…
Using a mulit-reflection time-of-flight mass spectrograph (MRTOF-MS) located after a gas cell coupled with the gas-filled recoil ion separator GARIS-II, the masses of several heavy nuclei have been directly and precisely measured. The…
A newly assembled multi-reflection time-of-flight mass spectrograph (MRTOF-MS) at RIKEN's RIBF facility became operational for the first time in spring 2020; further modifications and performance tests using stable ions were completed in…
High-precision mass measurements of $^{63}$Cu, $^{64-66}$Zn, $^{65}$Ga, $^{65-67}$Ge, $^{67}$As, $^{78,81}$Br, $^{80}$Rb, and $^{79}$Sr were performed utilizing a multireflection time-of-flight mass spectrograph combined with the gas-filled…
We characterize the mass bandwidth of the a multi-reflection time-of-flight mass spectrograph, showing both the functional and useful mass bandwidth. We then demonstrate the use of a multi-reflection time-of-flight mass spectrograph to…
We report precision mass measurements of $^{74-76}$Sr performed with the TITAN Multiple-Reflection Time-of-Flight Mass Spectrometer. This marks a first time mass measurement of $^{74}$Sr and gives increased mass precision to both $^{75}$Sr…
In applied forms of time-of-flight mass spectrometry utilizing ion storage devices prior to an analysis device, a non instantaneous electric ejection pulse applied in the region of ion storage is used to accelerate ions into the…
We introduce a new concomitant referencing mode for operating a multi-reflection time-of-flight mass spectrograph (MRTOF-MS), wherein the reference and analyte ions are interleaved on a cycle by cycle bases. Using this mode, we demonstrate…
A dedicated isochronous storage ring, named the Rare-RI Ring, was constructed at the RI Beam Factory of RIKEN, aiming at precision mass measurements of nuclei located in uncharted territories of the nuclear chart. The Rare-RI Ring employs…
Mass spectrometry is a widespread approach to work out what are the constituents of a material. Atoms and molecules are removed from the material and collected, and subsequently, a critical step is to infer their correct identities based…
A Multi-Reflection Time-of-Flight Mass Spectrometer (MR-ToF-MS) has been commissioned at the Ion-Guide Isotope Separator On-Line (IGISOL) facility. It consists of six electrode pairs that form a nearly energy-isochronous potential and a…
We have realized a high-resolution time-of-flight mass spectrometer combined with a magneto-optical trap. The spectrometer enables excellent optical access to the trapped atomic cloud using specifically devised acceleration and deflection…
Mass measurements of $^{49,50}$Sc, $^{70}$As, $^{73}$Br and $^{196}$Hg nuclides produced at CERN's radioactive-ion beam facility ISOLDE are presented. The measurements were performed at the ISOLTRAP mass spectrometer by use of the…
We report the mass measurements of neutron-rich isotopes produced via spontaneous fission of ${}^{252}$Cf using a multi-reflection time-of-flight mass spectrograph. The mass of ${}^{155}$Ce is determined experimentally for the first time. A…
The masses of $^{246}$Es, $^{251}$Fm and the transfermium nuclei $^{249-252}$Md, and $^{254}$No, produced by hot- and cold-fusion reactions, in the vicinity of the deformed $N=152$ neutron shell closure, have been directly measured using a…
Penning trap mass measurements of $^{149}$La, $^{149}$Ce, and $^{149}$Pr were performed with the Canadian Penning Trap (CPT) at the CARIBU facility of Argonne National Laboratory using the phase-imaging ion-cyclotron-resonance technique.…
The masses of 40 neutron-rich nuclides from Z = 51 to 64 were measured at an average precision of $\delta m/m= 10^{-7}$ using the Canadian Penning Trap mass spectrometer at Argonne National Laboratory. The measurements, of fission fragments…
The location of electron capture heat sources in the crust of accreting neutron stars depends on the masses of extremely neutron-rich nuclei. We present first results from a new implementation of the time-of-flight technique to measure…
We present an overview of a study on precise mass reconstruction and identification of charged hadrons ($\pi^{\pm}$, $K^{\pm}$, $p$) using time-of-flight measurements in the electromagnetic calorimeter of a typical Higgs factory detector.…
We report the mass measurement of $^{56}$Cu, using the LEBIT 9.4T Penning trap mass spectrometer at the National Superconducting Cyclotron Laboratory at Michigan State University. The mass of $^{56}$Cu is critical for constraining the…
To achieve high precision and accuracy for mass measurements of exotic nuclei by Time-of-flight (TOF) methods: high-resolution beam-line magnetic-rigidity time-of-flight (B$\rho$-TOF) and in-ring isochronous mass spectrometry (IMS), a…