Related papers: Another Detector for the International Linear Coll…
The 4th Concept detector presently being designed for the International Linear Collider introduces several innovations in order to achieve the necessary experimental goal of a detecter that is 2-to-10 times better than the already excellent…
The International Large Detector (ILD) is a concept for a detector at the International Linear Collider, ILC. The ILC will collide electrons and positrons at energies of initially 500 GeV, upgradeable to 1 TeV. The ILC has an ambitious…
This paper describes the design and construction of a Cherenkov detector conceived with regard to high energy Compton polarimeters for the International Linear Collider, where beam diagnostic systems of unprecedented precision must…
The first technological SDHCAL prototype having been successfully tested, a new phase of R&D, to validate completely the SDHCAL option for the International Linear Detector (ILD) project of the International Linear Collider (ILC), has…
A time projection chamber (TPC) with micropattern gaseous detector (MPGD) readout is investigated as main tracking device of the International Large Detector (ILD) concept at the planned International Linear Collider (ILC). A prototype TPC…
The Compact Linear Collider CLIC is designed to deliver e+e- collisions at a center of mass energy of up to 3 TeV. The detector systems at this collider have to provide highly efficient tracking and excellent jet energy resolution and…
The International Large Detector, ILD, is a detector concept for an experiment at a future high energy lepton collider. The detector has been optimised for precision physics in a range of energies from 90~GeV to about 1~TeV. ILD features a…
We report on the development of an GRPCs (Glass Resistive Plate chambers) Semi- Digital hadron calorimeter for the future International Linear Collider (ILC).Two types of GRPCs (small and 1m2) were tested in PS beam at CERN. Detector…
Any future high energy e+e- linear collider aims at precision measurements of Standard Model quantities as well as of new, not yet discovered phenomena. In order to pursue this physics programme, excellent detectors at the interaction…
The International Linear Collider (ILC) is a proposed electron-positron collider with a center-of-mass energy of 500~GeV, and a peak luminosity of $2 \cdot 10^{34}~\mathrm{cm}^{-2}\mathrm{s}^{-1}$. The ILC will complement the Large Hadron…
In this article, we describe the key features of the recently completed technical design for the International Linear Collider (ILC), a 200-500 GeV linear electron-positron collider (expandable to 1 TeV) that is based on 1.3 GHz…
This paper presents the status of Monte Carlo simulation of one of the luminosity detectors considered for the future e+e- International Linear Collider (ILC). The detector consists of a tungsten/silicon sandwich calorimeter with pad…
For the International Large Detector (ILD) at the planned International Linear Collider (ILC) a Time Projection Chamber (TPC) is foreseen as the main tracking detector. To achieve the required point resolution, Micro Pattern Gaseous…
The DEPFET Collaboration pursues the development of a high resolution pixel vertex detector for future colliders (like ILC), based on the integration of amplifying transistors into a fully depleted bulk. In August 2008, six DEPFET…
The ILD detector is proposed for an electron-positron collider with collision centre-of-mass energies from 90~\GeV~to about 1~\TeV. It has been developed over the last 10 years by an international team of scientists with the goal to design…
The SiD Detector is one of two detector designs for the future International Linear Collider (ILC) that were validated in 2012 SiD features a compact, cost-constrained design for precision Higgs and other measurements, and sensitivity to a…
The physics goals at the future e+e- linear collider require high performance vertexing and impact parameter resolution. Two possible technologies for the vertex detector of an experimental apparatus are outlined in the paper: an evolution…
The SiD Detector is one of two validated detector designs for the future International Linear Collider. SiD features a compact, cost-constrained design for precision Higgs couplings determination, and other measurements, and sensitivity to…
A new design of highly granular hadronic calorimeter using Glass Resistive Plate Chambers (GRPCs) with embedded electronics has been proposed for the future International Linear Collider (ILC) experiments. It features a 2-bit threshold…
The e+e- linear collider physics programme sets highly demanding requirements on the accurate determination of charged particle trajectories close to their production point. A new generation of Vertex Trackers, based on different…