English
Related papers

Related papers: Simple vibration insensitive cavity for laser stab…

200 papers

We report on an ultrastable molecular clock based on the interrogation of the 3{\nu} rotational-vibrational combination band at 1563nm of carbon monoxide 12C16O. The laser stabilization scheme is based on frequency modulation (FM)…

Atomic Physics · Physics 2016-05-25 Shailendar Saraf , Paul Berceau , Alberto Stochino , Robert Byer , John Lipa

Optical resonators are used for the realisation of ultra-stable frequency lasers. The use of high reflectivity multi-band coatings allows the frequency locking of several lasers of different wavelengths to a single cavity. While the noise…

We describe the design, construction, and characterization of a medium-finesse Fabry-P\'erot cavity for simultaneous frequency stabilization of two lasers operating at 960 and 780 nm wavelengths, respectively. The lasers are applied in…

Instrumentation and Detectors · Physics 2018-05-23 Julius de Hond , Nataly Cisternas , Graham Lochead , N. J. van Druten

Photonic integration offers the potential to bring complex high-performance optical systems to the form factor of a compact semiconductor chip. However, the range of system functions accessible critically depends on the extent to which…

An extended cavity diode laser operating in the Littrow configuration emitting near 657 nm is stabilized via its injection current to a reference cavity with a finesse of more than 10^5 and a corresponding resonance linewidth of 14 kHz. The…

Optics · Physics 2009-11-07 Adrien Schoof , Jan Gruenert , Stephan Ritter , Andreas Hemmerich

Thermal noise of the dielectric mirror coatings can limit laser-optical high-precision measurements. Coatings made of amorphous silicon and silicon nitride could provide a remedy for both gravitational-wave detectors and optical clocks.…

Compact optical clocks with high stability are essential for next-generation frequency standard field applications, from navigation to geodesy, yet existing vapor cell clock systems have remained confined to fractional instabilities over…

We present a solid-state laser system that generates over 200 mW of continuous-wave, narrowband light, tunable from 316.3 nm - 317.7 nm and 318.0 nm - 319.3 nm. The laser is based on commercially available fiber amplifiers and optical…

We demonstrate thermal-noise-limited direct locking of a semiconductor distributed feedback (DFB) laser to a sub-1 mL volume, ultrastable optical cavity, enabling extremely compact and simple ultrastable laser systems. Using the…

We demonstrate a micro-Fabry-P\'erot cavity array through laser etching of high-surface-quality mirrors onto a single fused silica substrate. A cavity finesse of $4750\pm 200$ was achieved with a simple array design with $500~\mu m$ cavity…

We develop and demonstrate a compact (less than $6$ mL) portable Fabry-P\'{e}rot optical reference cavity. A laser locked to the cavity is thermal noise limited at $2\times10^{-14}$ fractional frequency stability. Broadband feedback control…

We demonstrate a powerful tool for high-resolution mid-IR spectroscopy and frequency metrology with quantum cascade lasers (QCLs). We have implemented frequency stabilization of a QCL to an ultra-low expansion (ULE) reference cavity, via…

Narrow linewidth stabilized lasers are central to precision applications that operate across the visible to short-wave infrared wavelengths, including optical clocks, quantum sensing and computing, ultra-low noise microwave generation, and…

Two nominally identical ultra-stable cryogenic microwave oscillators are compared. Each incorporates a dielectric-sapphire resonator cooled to near 6 K in an ultra-low vibration cryostat using a low-vibration pulse-tube cryocooler. The…

Instrumentation and Detectors · Physics 2012-05-15 John G. Hartnett , Nitin R. Nand , Chuan Lu

We explore the potential of direct spectroscopy of ultra-narrow optical transitions of atoms localized in an optical cavity. In contrast to stabilization against a reference cavity, which is the approach currently used for the most highly…

Quantum Physics · Physics 2015-05-28 M. J. Martin , D. Meiser , J. W. Thomsen , Jun Ye , M. J. Holland

Low frequency high precision laser interferometry is subject to excess laser-frequency-noise coupling via arm-length differences which is commonly mitigated by locking the frequency to a stable reference system. This approach is crucial to…

Instrumentation and Detectors · Physics 2017-03-01 Oliver Gerberding , Katharina-Sophie Isleif , Moritz Mehmet , Karsten Danzmann , Gerhard Heinzel

Near-unstable cavities have been proposed as an enabling technology for future gravitational wave detectors, as their compact structure and large beam spots can reduce the coating thermal noise of the interferometer. We present a tabletop…

Instrumentation and Methods for Astrophysics · Physics 2018-01-24 Haoyu Wang , Miguel Dovale Alvarez , Christopher Collins , Daniel David Brown , Mengyao Wang , Conor M. Mow-Lowry , Sen Han , Andreas Freise

A fundamental limit to the stability of a single-ion optical frequency standard is set by quantum noise in the measurement of the internal state of the ion. We discuss how the interrogation sequence and the processing of the atomic…

Atomic Physics · Physics 2009-11-11 Ekkehard Peik , Tobias Schneider , Christian Tamm

Quantum information processing using atomic qubits requires narrow linewidth lasers with long-term stability for high fidelity coherent manipulation of Rydberg states. In this paper, we report on the construction and characterization of…

Atomic Physics · Physics 2018-03-23 R. Legaie , C. J. Picken , J. D. Pritchard

Lasing in the bad-cavity regime has promising applications in precision measurement and frequency metrology due to the reduced sensitivity of the laser frequency to cavity length fluctuations. Thus far, relevant studies have been mainly…

Optics · Physics 2023-10-24 Jia Zhang , Tiantian Shi , Jianxiang Miao , Deshui Yu , Jingbiao Chen