Related papers: Readout electronics of silicon detectors used in s…
Compact multi-channel radiation detectors rely on low noise front-end application specific integrated circuits (ASICs) to achieve high spectral resolution. Here, a new ASIC developed to readout virtual Frisch-grid cadmium zinc telluride…
Time and charge measurements over a large dynamic range from 1 Photo Electron (P.E.) to 4000 P.E. are required for the Water Cherenkov Detector Array (WCDA), which is one of the key components in the Large High Altitude Air Shower…
A prototype flash analog-to-digital readout system for cosmic ray detection at energies below 10^18 eV has been designed and tested at Columbia University Nevis Laboratories. The electronics consist of an FADC module that digitizes 16…
A high-granularity telescope system with a large sensitive area and low material budget has been developed for high-energy heavy ion beam tests. The telescope consists of nine layers of silicon microstrip detectors (SSDs), whose performance…
Modern PET scanners based on scintillating crystals use solid state photo detectors for light readout. The small area of these devices is beneficial for spatial resolution, but also leads to a large number of electronic channels to be read…
The Large High Altitude Air Shower Observatory is in the R&D phase, in which the Water Cherenkov Detector Array is an important part. The signals of Photo-Multiplier Tubes would vary from single photo electron to 4000 photo electrons, and…
While designed primarily for X-ray imaging applications, the Medipix3 ASIC can also be used for charged-particle tracking. In this work, results from a beam test at the CERN SPS with irradiated and non-irradiated sensors are presented and…
3D silicon detectors are characterized by cylindrical electrodes perpendicular to the surface and penetrating into the bulk material in contrast to standard Si detectors with planar electrodes on its top and bottom. This geometry renders…
Multiple application-specific integrated circuits (ASIC) are required for the detectors if their readout channels are larger than that of ASIC channels. For a system with such a readout scheme, there is a need to configure channels among…
A 64-channel mixed-mode ASIC, suitable for particle detectors of large dynamic range and high capacitance up to hundreds of pF, is presented here. Each channel features an analogue front-end for signal amplification and filtering, and a…
TIGER (Turin Integrated Gem Electronics for Readout) is a mixed-mode front-end ASIC developed to readout the new inner tracking detector of the BESIII experiment, carried out at BEPCII in Beijing. The detector is planned to be installed…
The Silicon Tracker (STK) is a detector of the DAMPE satellite to measure the incidence direction of high energy cosmic ray. It consists of 6 X-Y double layers of silicon micro-strip detectors with 73,728 readout channels. It's a great…
PARISROC is a complete read out chip, in AMS SiGe 0.35 micron technology [1], for photomultipliers array. It allows triggerless acquisition for next generation neutrino experiments and it belongs to an R&D program funded by the French…
Microwave Kinetic Inductance Detectors (MKID) are a promising solution for spaceborne mm-wave astronomy. To optimize their design and make them insensitive to the ballistic phonons created by cosmic-ray interactions in the substrate, the…
We report on a large active area (15x15mm2), high channel density (470 pixels/mm2), self-triggering CMOS analog chip that we have developed as pixelized charge collecting electrode of a Micropattern Gas Detector. This device, which…
We characterize the response of a novel 250 $\mu$m thick, fully-depleted Skipper Charged-Coupled Device (CCD) to visible/near-infrared light with a focus on potential applications for astronomical observations. We achieve stable,…
PARISROC is a complete read out chip, in AMS SiGe 0.35 !m technology, for photomultipliers array. It allows triggerless acquisition for next generation neutrino experiments and it belongs to an R&D program funded by the French national…
CEPC (Circular Electron and Positron Collider) is a large experiment facility proposed by Chinese particle physics community. One of its running option is being the Higgs factory. Calorimeter is the main part of this experiment to measure…
The MIDNA application specific integrated circuits (ASICs) are a series of skipper-CCD readout chips fabricated in a 65 nm low-power CMOS process that implement a correlated double sampling signal processing chain based on dual-slope…
We characterize a new x-ray Mixed-Mode Pixel Array Detector (MM-PAD-2.1) Application Specific Integrated Circuit (ASIC). Using an integrating pixel front-end with dynamic charge removal architecture, the MM-PAD-2.1 ASIC extends the maximum…