In this paper, we present a Fingerprint Linear Estimation Routine (FLiER) to identify topology changes in power networks using readings from sparsely-deployed phasor measurement units (PMUs). When a power line, load, or generator trips in a…
Phasor measurement units (PMUs) are integrated to the transmission networks under the smart grid umbrella. The observability of PMUs is geographically limited due to their high cost in integration. The measurements of PMUs can be…
In this paper, phasor measurement unit (PMU) placement for power grid state estimation under different degrees of observability is studied. Observability degree is the depth of the buses' reachability by the placed PMUs and thus constitutes…
This research proposes a machine learning-based attack detection model for power systems, specifically targeting smart grids. By utilizing data and logs collected from Phasor Measuring Devices (PMUs), the model aims to learn system…
The expansion in technology and attainability of a large number of sensors has led to a huge amount of real-time streaming data. The real-time data in the electrical distribution system is collected through distribution-level phasor…
Power system dynamics are naturally nonlinear. The nonlinearity stems from power flows, generator dynamics, and electromagnetic transients. Characterizing the nonlinearity of the dynamical power system model is useful for designing superior…
Voltage stability in modern power systems involves coupled dynamics across multiple time scales. Conventional methods based on time-scale separation or static stability margins may overlook instabilities caused by the coupling of slow and…
As phasor measurement units (PMUs) become more widely used in transmission power systems, a fast state estimation (SE) algorithm that can take advantage of their high sample rates is needed. To accomplish this, we present a method that uses…
Online transmission line outage detection over the entire network enables timely corrective action to be taken, which prevents a local event from cascading into a large scale blackout. Line outage detection aims to detect an outage as soon…
In this paper, a novel method to estimate dynamic load parameters via ambient PMU measurements is proposed. Unlike conventional parameter identification methods, the proposed algorithm does not require the existence of large disturbance to…
In modern distribution systems, load uncertainty can be fully captured by micro-PMUs, which can record high-resolution data; however, in practice, micro-PMUs are installed at limited locations in distribution networks due to budgetary…
Data quality of Phasor Measurement Unit (PMU) is receiving increasing attention as it has been identified as one of the limiting factors that affect many wide-area measurement system (WAMS) based applications. In general, existing PMU…
Proliferation of advanced metering devices with high sampling rates in distribution grids, e.g., micro-phasor measurement units ({\mu}PMU), provides unprecedented potentials for wide-area monitoring and diagnostic applications, e.g.,…
The increasing adoption of measurement units in electrical power distribution grids has enabled the deployment of data-driven and measurement-based control schemes. Such schemes rely on measurement-based estimated models, where the models…
Diverse fault types, fast re-closures, and complicated transient states after a fault event make real-time fault location in power grids challenging. Existing localization techniques in this area rely on simplistic assumptions, such as…
Based on phasor measurement units (PMUs), a synchronphasor system is widely recognized as a promising smart grid measurement system. It is able to provide high-frequency, high-accuracy phasor measurements sampling for Wide Area Monitoring…
We present pmuGE (phasor measurement unit Generator of Events), one of the first data-driven generative model for power system event data. We have trained this model on thousands of actual events and created a dataset denoted pmuBAGE (the…
Over the last few decades, extensive use of information and communication technologies has been the main driver of the digitalization of power systems. Proper and secure monitoring of the critical grid infrastructure became an integral part…
This paper presents an innovative approach to micro-phasor measurement unit (micro-PMU) placement in unbalanced distribution networks. The methodology accounts for the presence of single-and-two-phase laterals and acknowledges the fact that…
If a Micro Processor Unit (MPU) receives an external electric signal as noise, the system function will freeze or malfunction easily. A new resilience strategy is implemented in order to reset the MPU automatically and stop the MPU from…