ALLEGRO is an experimental high-temperature gas (He)-cooled fast reactor (GFR) under development by the European Consortium V4G4 Centre of Excellence on basis of the concept ALLEGRO presented by CEA in 2009. Its main purpose is to…

Instrumentation and Detectors · Physics 2018-03-22 Petr Vacha , Ladislav Belovsky

This paper presents progress on the development of a cryostat intended to improve upon the low-energy threshold (below 0.5 keV) of p-type point contact germanium gamma-ray spectrometers. Ultra-low energy thresholds are important in the…

We have developed low temperature part of an ultra high vacuum scanning probe microscope (UHV-SPM) working at variable temperature within the range from 20 K to 700 K. To achieve the required temperature range, a flow cooling system using…

Instrumentation and Detectors · Physics 2016-10-04 Jiri Frolec , Jakub Vonka , Pavel Hanzelka , Tomas Kralik , Vera Musilova , Pavel Urban

This paper presents the design, safety basis, and commissioning results of a 1 K liquid helium-4 (4He) evaporation refrigerator developed for the Fermilab SpinQuest Experiment (E1039). The system represents the first high power helium…

Instrumentation and Detectors · Physics 2025-11-14 Jordan D. Roberts , Vibodha Bandara , Kenichi Nakano , Dustin Keller

Applications for ultra-stable lasers outside controlled laboratory environments require compact and robust optical resonators with reduced sensitivity to temperature fluctuations. The low thermal expansion coefficient (CTE) and the high…

Optics · Physics 2026-05-07 Nico Wagner , Thomas Legero , Stefanie Kroker

We describe a cryogenic instrumentation platform incorporating commercially-available field-programmable gate arrays (FPGAs) configured to operate well beyond their specified temperature range. The instrument enables signal routing,…

Instrumentation and Detectors · Physics 2016-01-20 I. D. Conway Lamb , J. I. Colless , J. M. Hornibrook , S. J. Pauka , S. J. Waddy , M. K. Frechtling , D. J. Reilly

The nuSTORM facility has been designed to deliver beams of electron and muon neutrinos from the decay of a stored muon beam with a central momentum of 3.8 GeV/c and a momentum spread of 10%. The facility is unique in that it will: serve the…

Accelerator Physics · Physics 2013-05-08 D. Adey , S. K. Agarwalla , C. M. Ankenbrandt , R. Asfandiyarov , J. J. Back , G. Barker , E. Baussan , R. Bayes , S. Bhadra , V. Blackmore , A. Blondel , S. A. Bogacz , C. Booth , S. B. Boyd , A. Bravar , S. J. Brice , A. D. Bross , F. Cadoux , H. Cease , A. Cervera , J. Cobb , D. Colling , L. Coney , A. Dobbs , J. Dobson , A. Donini , P. J. Dornan , M. Dracos , F. Dufour , R. Edgecock , J. Evans , M. A. George , T. Ghosh , A. deGouvea , J. J. Gomez-Cadenas , A. Haesler , G. Hanson , M. Geelhoed , P. F. Harrison , M. Hartz , P. Hernandez , J. A. Hernando-Morata , P. J. Hodgson , P. Huber , A. Izmaylov , Y. Karadhzov , T. Kobilarcik , J. Kopp , L. Kormos , A. Korzenev , A. Kurup , Y. Kuno , P. Kyberd , J. P. Lagrange , A. M. Laing , J. Link , A. Liu , K. R. Long , N. McCauley , K. T. McDonald , K. Mahn , C. Martin , J. Martin , O. Mena , S. R. Mishra , N. Mokhov , J. Morfin , Y. Mori , W. Murray , D. Neuffer , R. Nichol , E. Noah , M. A. Palmer , S. Parke , S. Pascoli , J. Pasternak , M. Popovic , P. Ratoff , M. Ravonel , M. Rayner , S. Ricciardi , C. Rogers , P. Rubinov , E. Santos , A. Sato , E. Scantamburlo , J. K. Sedgbeer , D. R. Smith , P. J. Smith , J. T. Sobczyk , S. Soldner-Rembold , F. J. P. Soler , M. Sorel , A. Stahl , L. Stanco , P. Stamoulis , S. Striganov , H. Tanaka , I. J. Taylor , C. Touramanis , C. D. Tunnel , Y. Uchida , N. Vassilopoulos , M. O. Wascko , A. Weber , E. Wildner , M. J. Wilking , W. Winter , U. K. Yang

We report experimental demonstration of the feasibility of reaching temperatures below 1 mK using cryogen-free technology. Our prototype system comprises an adiabatic nuclear demagnetisation stage, based on hyperfine-enhanced nuclear…

Instrumentation and Detectors · Physics 2015-06-16 Graham Batey , Andrew Casey , Michael Cuthbert , Anthony Matthews , John Saunders , Aya Shibahara

We report on the design, development, and installation of the ALPS Cryo-Platform Subcooler Box (ACPS), which is part of the cryogenic platform being established in the HERA North Hall at DESY to supply helium for cooling large-scale…

Instrumentation and Detectors · Physics 2026-01-14 Udai Raj Singh , Rajinikumar Ramalingam , Christoph Reinhardt , Olaf Korth , Jörg Penning , Jörn Schaffran , Axel Lindner

CRESST-II, standing for Cryogenic Rare Events Search with Superconducting Thermometers phase II, is an experiment searching for Dark Matter. In the LNGS facility in Gran Sasso, Italy, a cryogenic detector setup is operated in order to…

We present the performances of Li-based compounds used as scintillating bolometer for rare decay studies such as double-beta decay and direct dark matter investigations. The compounds are tested in a dilution refrigerator installed in the…

Instrumentation and Detectors · Physics 2014-03-12 L. Pattavina

In this article we describe the background challenges for the CUORE experiment posed by surface contamination of inert detector materials such as copper, and present three techniques explored to mitigate these backgrounds. Using data from a…

Nuclear Experiment · Physics 2013-04-05 F. Alessandria , R. Ardito , D. R. Artusa , F. T. Avignone , O. Azzolini , M. Balata , T. I. Banks , G. Bari , J. Beeman , F. Bellini , A. Bersani , M. Biassoni , T. Bloxham , C. Brofferio , C. Bucci , X. Z. Cai , L. Canonica , S. Capelli , L. Carbone , L. Cardani , M. Carrettoni , N. Casali , N. Chott , M. Clemenza , C. Cosmelli , O. Cremonesi , R. J. Creswick , I. Dafinei , A. Dally , V. Datskov , A. De Biasi , M. M. Deninno , S. Di Domizio , M. L. di Vacri , L. Ejzak , R. Faccini , D. Q. Fang , H. A. Farach , E. Ferri , F. Ferroni , E. Fiorini , M. A. Franceschi , S. J. Freedman , B. K. Fujikawa , A. Giachero , L. Gironi , A. Giuliani , J. Goett , A. Goodsell , P. Gorla , C. Gotti , E. Guardincerri , T. D. Gutierrez , E. E. Haller , K. Han , K. M. Heeger , H. Z. Huang , R. Kadel , K. Kazkaz , G. Keppel , L. Kogler , Yu. G. Kolomensky , D. Lenz , Y. L. Li , C. Ligi , X. Liu , Y. G. Ma , C. Maiano , M. Maino , M. Martinez , R. H. Maruyama , Y. Mei , N. Moggi , S. Morganti , T. Napolitano , S. Newman , S. Nisi , C. Nones , E. B. Norman , A. Nucciotti , F. Orio , D. Orlandi , J. L. Ouellet , M. Pallavicini , V. Palmieri , L. Pattavina , M. Pavan , M. Pedretti , G. Pessina , S. Pirro , E. Previtali , V. Rampazzo , R. Reil , F. Rimondi , C. Rosenfeld , C. Rusconi , S. Sangiorgio , N. D. Scielzo , M. Sisti , A. R. Smith , L. Sparks , F. Stivanello , L. Taffarello , M. Tenconi , W. D. Tian , C. Tomei , S. Trentalange , G. Ventura , M. Vignati , B. S. Wang , H. W. Wang , C. A. Whitten , T. Wise , A. Woodcraft , L. Zanotti , C. Zarra , B. X. Zhu , S. Zucchelli

The Scanning Quantum Cryogenic Atom Microscope (SQCRAMscope) is a quantum sensor in which a quasi-1D quantum gas images electromagnetic fields emitted from a nearby sample. We report improvements to the microscope. Cryogen usage is reduced…

Atomic Physics · Physics 2021-03-10 Stephen F. Taylor , Fan Yang , Brandon A. Freudenstein , Benjamin L. Lev

This study shows the development and performance assessment of a novel set-up that enables the research of structural materials for fusion reactors, by making possible simultaneous application of temperature (up to 450$^{\circ}$C) and…

Instrumentation and Detectors · Physics 2019-05-30 I. Garcia-Cortes , S. Cabrera , M. Medrano , A. Moroño , P. Muñoz , A. Soleto , I. Bugallo , A. Nieto , R. Altimira , A. Bollero , J. Camarero , J. L. F. Cuñado

We perform the characterization and modeling of a floating-gate device realized with a commercial 350-nm CMOS technology at cryogenic temperature. The programmability of the device offers a solution in the realization of a precise and…

Applied Physics · Physics 2021-10-25 Michele Castriotta , Enrico Prati , Giorgio Ferrari

We developed a simple, flexible, low-cost, and computer-controlled cryogenic temperature measurement system for undergraduate instructional laboratories. An Arduino microcontroller board measures the voltage across a silicon diode to…

Physics Education · Physics 2020-01-29 Woong Sung Lee

A recent reconsideration of a theoretical process of a neutrinoless double beta decay points out that a signal of the decay should be shifted by a few keV from the Q-value for the 2{\ss}0{\nu}-decay. The conclusion was based on an analysis…

Nuclear Experiment · Physics 2015-09-15 I. V. Kirpichnikov

ICARUS T600 liquid argon time projection chamber is the first large mass electronic detector of a new generation able to combine the imaging capabilities of the old bubble chambers with the excellent calorimetric energy measurement. After…

Liquid free cryogenic devices are acquiring importance in basic science and engineering. But they can also lead to improvements in teaching low temperature an solid state physics to graduate students and specialists. Most of the devices are…

Physics Education · Physics 2012-07-26 M. R. Osorio , A. Palacio Morales , J. G. Rodrigo , H. Suderow , S. Vieira