Related papers: Flux calibration of the Herschel-SPIRE photometer
The Spectral Energy Distribution (SED) mode of the Multiband Imaging Photometer for Spitzer (MIPS) Space Telescope provides low-spectral resolution (R ~ 15-25) spectroscopy in the far infrared using the MIPS 70 um detector. A reflective…
Increase in the Balmer continuum radiation during solar flares was predicted by various authors but never firmly confirmed observationally using ground-based slit spectrographs. Here we describe a new post-focal instrument - Image Selector…
The Gaia mission is described, focussing on those technical aspects that are necessary to understand the details of its external (absolute) flux calibration. On board of Gaia there will be two (spectro)photometers, the blue one (BP) and the…
We derive bolometric correction functions for oscillation mode amplitudes observed by the different cameras of the ESA PLATO mission. Such corrections between bolometric (full light) and mission instrument-specific amplitudes enable…
We investigate the utility of the Tunable Filters (TFs) for obtaining flux calibrated emission line maps of extended objects such as galactic nebulae and nearby galaxies, using the OSIRIS instrument at the 10.4-m GTC. Despite a relatively…
A systematic programme of calibration observations was carried out to monitor the performance of the SPIRE FTS instrument on board the Herschel Space Observatory. Observations of planets (including the prime point-source calibrator,…
Mid-IR albedo values of Neptune are derived from Spitzer Space Telescope measurements reported by Stauffer et al. (2016). The method of this derivation is described and the results indicate that the geometric albedo was about 1% or less at…
An undersampled point spread function may interact with the microstructure of a solid-state detector such that the total flux detected can depend sensitively on where the PSF center falls within a pixel. Such intra-pixel sensitivity…
The Near-Infrared Spectrometer and Photometer (NISP) on board the Euclid satellite provides multiband photometry and R>=450 slitless grism spectroscopy in the 950-2020nm wavelength range. In this reference article we illuminate the…
Optimal error estimation is key to achieve accurate photometry and astrometry. Stellar fluxes and positions in high angular resolution images are typically measured with PSF fitting routines, such as StarFinder. However, the formal…
We present a new method for optimally extracting point-source time variability information from a series of images. Differential photometry is generally best accomplished by subtracting two images separated in time, since this removes all…
High redshift star-forming galaxies are discovered routinely through a flux excess in narrowband filters (NB) caused by an emission line. In most cases, the width of such filters is broad compared to typical line widths, and the throughput…
A method of distributed calibration of a probe microscope scanner is suggested which main idea consists in a search for a net of local calibration coefficients (LCCs) in the process of automatic measurement of a standard surface, whereby…
We describe the application of a statistical method to estimate submillimeter galaxy number counts from confusion limited observations by the Balloon-borne Large Aperture Submillimeter Telescope (BLAST). Our method is based on a maximum…
We present a novel method to accurately determine the flux of neutrinos and antineutrinos, one of the dominant systematic uncertainty affecting current and future long-baseline neutrino experiments, as well as precision neutrino scattering…
Future far-infrared space missions require highly-sensitive spectroscopy as a primary diagnostics tool. However, these systems are sensitive to straylight, due to the ultra-sensitive few-mode detectors used, which affects the measurement…
The Palomar Transient Factory (PTF) provides multiple epoch imaging for a large fraction of the sky. Here we describe the photometric calibration of the PTF data products that relates the PTF magnitudes to other mag systems. The calibration…
Two independent methods are employed to measure the neutrino flux of the anti-neutrino-mode beam observed by the MiniBooNE detector. The first method compares data to simulated event rates in a high purity $\numu$ induced charged-current…
This paper discusses the Cosmic Background (CB) dipoles observations in the framework of the Planck mission. Dipoles observations can be used in three ways: (i) It gives a measurement of the peculiar velocity of our Galaxy which is an…
Accurate conversion of neutron time-of-flight (TOF) to wavelength, and its uncertainty, is of fundamental importance to neutron scattering measurements. Especially in cases where instruments are highly configurable, the determination of the…