English
Related papers

Related papers: AC vs. DC Electrophoretic Deposition of Hydroxyapa…

200 papers

The dispersion of anatase phase TiO2 powder in aqueous suspensions was investigated by zeta-potential and agglomerate size analysis. The iso-electric point (IEP) of anatase was determined to be at pH 2.8 using monoprotic acids for pH…

Materials Science · Physics 2013-03-13 D. A. H. Hanaor , M. Michelazzi , P. Veronesi , C. Leonelli , M. Romagnoli , C. C. Sorrell

This study aims at revealing the effect of composition on mechanical and antibacterial properties of hydroxyapatite/gray Titania coating for biomedical applications. HAp is a bioceramic material used as a plasma-sprayed coating to promote…

Medical Physics · Physics 2021-05-12 Mirazul Mahmud Abir

Hydroxyapatite (HAp) is an important component of mammal bones and teeth, being widely used in prosthetic implants. Despite the importance of HAp in medicine, several promising applications involving this material e.g. in photo-catalysis),…

Coarse (<=20 micron) titanium particles were deposited on low-carbon steel substrates by cathodic electrophoretic deposition (EPD) with ethanol as suspension medium and poly(diallyldimethylammonium chloride) (PDADMAC) as polymeric charging…

Materials Science · Physics 2013-09-13 Kok-Tee Lau , C. C. Sorrell

Hydroxyapatite (HA) on a magnesium (Mg) surface is studied using density functional theory, to help understand the effect of HA coating and alloying in the surfaces of Mg-based biodegradable implants. We determine the adsorption energies…

The results of XPS measurements (core levels and valence bands) of P+, Ca+, P+Ca+ and Ca+P+ ion implanted (E=30 keV, D=1x1017 cm-2) commercially pure titanium (cp-Ti) and first-principles density functional theory (DFT) calculations…

Passivating lithium ion battery electrode surfaces to prevent electrolyte decomposition is critical for battery operations. Recent work on conformal atomic layer deposition (ALD) coating of anodes and cathodes has shown significant…

This paper presents a comprehensive study of cerium-doped hydroxyapatite (Ce-HAp), a material of interest for biomedical applications due to the good biocompatibility of hydroxyapatite and the antioxidant activity of cerium ions. We employ…

We have studied the processing of piezoelectric thick films using electrophoretic deposition (EPD) for high-frequency ultrasound applications. Lead-zirconium-titanate (PZT) particles synthetized by solid states synthesis were dispersed in…

A new strategy with bone tissue engineering by mesenchymal stem cell transplantation on titanium implant has been dawn attention. The surface scaffold properties of titanium surface play an important role in bone regenerative potential of…

Cell Behavior · Quantitative Biology 2010-05-03 Yukimichi Tamaki , Yu Kataoka , Takashi Miyazaki

The development of tissue engineering structures (scaffolds) for the reconstruction of bone tissue defects is the relevant task of modern biomedical materials science. Compared to metal-based structures, polymer constructs provide numerous…

Titanium alloys are promising candidates for orthopedic implants due to their mechanical resilience and biocompatibility. Current titanium alloys in orthopedic implants still suffer from low wear and corrosion resistance. Here, we present a…

Medical Physics · Physics 2023-07-06 Noel Siony , Long Vuong , Otgonsuren Lundaajamts , Sara Kadkhodaei

A thin coating of thorium on aluminium substrates with the areal density of 110 to 130 $\mu g/cm^2$ is developed over a circular area of 22 mm diameter by using the electrodeposition method. An electrodeposition system is fabricated to…

Instrumentation and Detectors · Physics 2023-03-28 Dal-Ho Moon , Vivek Chavan , Vasant Bhoraskar , Yeong Hoon Jeong , Jung Ho Park , Su-Jeong Suh , Seung-Woo Hong

DC electrical degradation as a form of dielectric and resistance breakdown is a common phenomenon in thin-film devices including resistance-switching memory. To obtain design data and to probe the degradation mechanism, highly accelerated…

Materials Science · Physics 2019-07-17 Ana Alvarez , Yanhao Dong , I-Wei Chen

Direct and alternating current iontophoresis and electro-osmosis methodologies have provided new methods of transcutaneous drug delivery. A byproduct of such methods is lowering the electrical impedance of the electrode to skin contact, as…

Medical Physics · Physics 2017-11-06 Pavel Govyadinov , Sergei Turovets , Amanda Gunn , Don Tucker , Phan Luu

Electrodeposition of tantalum coating was performed from an ionic liquid, BMP[Tf2N], in the presence of dissolved anhydrous TaF5 and LiF. Superficial X-ray photoelectron spectroscopy supplemented by an argon ion etching and depth profiling…

Applied Physics · Physics 2025-05-27 Helena Simunkova , Eva Kolibalova , Lukas Kalina , Tomas Lednicky , Jaromir Hubalek

Since a long time the application of small electric potentials on biological membranes (iontophoresis) proved enabling control and improvement of transdermal delivery of substances across this barrier. In spite of a large experimental data,…

Tissues and Organs · Quantitative Biology 2019-05-07 Neila Machado , Clarissa Callegaro , Marcelo Augusto Christoffolete , Herculano Martinho

Dielectric barrier discharge (DBD) plasma actuators generate an electrohydrodynamic (EHD) force through the ionization and acceleration of charged species. Most active flow control DBD applications are only practical at lower Reynolds…

Plasma Physics · Physics 2024-11-27 Anthony Tang , Alexander Mamishev , Igor Novosselov

High entropy oxides (HEO) hold the potential to revolutionize the conventional material paradigms by leveraging high order of chemical disorder that induces highly desirable exotic phases for advanced applications. Here, we devise a…

Electrolyte gating is a powerful technique for accumulating large carrier densities in surface two-dimensional electron systems (2DES). Yet this approach suffers from significant sources of disorder: electrochemical reactions can damage or…

‹ Prev 1 2 3 10 Next ›