English
Related papers

Related papers: Prototype of time digitizing system for BESIII end…

200 papers

A Time of Flight monitoring system has been developed for BES3. The light source is a 442-443 nm laser diode, which is stable and provides a pulse width as narrow as 50 ps and a peak power as large as 2.6 W. Two optical-fiber bundles with a…

Instrumentation and Detectors · Physics 2008-11-26 F. A. Harris , J. W. Kennedy , Q. Liu , L. Nguyen , S. L. Olsen , M. Rosen , C. P. Shen , G. S. Varner , Y. K. Heng , Z. J. Sun , K. J. Zhu , Q. An , C. Q. Feng , S. B. Liu

We present in this work the calibration procedure and a performance study of long scintillator bars used for the time-of-flight (TOF) measurement in the HADES experiment. The digital front-end electronics installed at the TOF detector…

Instrumentation and Detectors · Physics 2021-03-15 G. Kornakov , L. Chlad , J. Friese , T. Galatyuk , A. Kugler , J. Markert , J. Michel , J. Pietraszko , O. Svoboda , P. Tlusty , M. Traxler

Timing-pick up detectors with excellent timing resolutions are essential in many modern nuclear physics experiments. Aiming to develop a Time-Of-Flight system with precision down to about 10 ps, we have made a systematic study of the timing…

Instrumentation and Detectors · Physics 2016-04-19 J. W. Zhao , B. H. Sun , I. Tanihata , S. Terashima , L. H. Zhu , A. Enomoto , D. Nagae , T. Nishimura , S. Omika , A. Ozawa , Y. Takeuchi , T. Yamaguchi

Time-of-flight measurement is an important advancement in PET scanners to improve image reconstruction with a lower delivered radiation dose. This article describes the monolithic ASIC for the TT-PET project, a novel idea for a…

In the existing literature on joint timing and frequency synchronization of orthogonal time frequency space modulation (OTFS), practically infeasible impulse pilot with large peak-to-average power ratio (PAPR) is deployed. Hence, in this…

Signal Processing · Electrical Eng. & Systems 2023-01-25 Mohsen Bayat , Sanoopkumar P. S. , Arman Farhang

Back-n is a white neutron experimental facility at China Spallation Neutron Source (CSNS). The time structure of the primary proton beam make it fully applicable to use TOF (time-of-flight) method for neutron energy measuring. We implement…

We present the design and performance of a prototype ASIC digitizer for integrated wire chamber readout, implemented in 65 nm commercial CMOS technology. Each channel of the 4-channel prototype is composed of two 16-bit Time-to-Digital…

This study presents a novel field-programmable gate array (FPGA)-based Time-to-Digital Converter (TDC) design suitable for high timing resolution applications, utilizing two new techniques. First, a cross-detection (CD) method is introduced…

Instrumentation and Detectors · Physics 2024-10-15 Daehee Lee , Minseok Yi , Sun Il Kwon

The time-of-flight (TOF) system in the Compressed Baryonic Matter (CBM) experiment is composed of super modules based on multi-gap Resistive Plate Chambers (MRPC) for high-denseness, high-resolution time measurement. In order to evaluate…

Instrumentation and Detectors · Physics 2019-09-04 Jiawen Li , Xiru Huang , Ping Cao , Chao Li , Jianhui Yuan , Wei Jiang , Junru Wang , Qi An

The new CDFII detector incorporates a Time-of-Flight detector (TOF), employing plastic scintillator bars and fine-mesh photomultipliers. Since August 2001 the TOF system has been fully instrumented and integrated into the CDFII data…

The upgrade of the ATLAS muon spectrometer for high-luminosity LHC requires new trigger and readout electronics for the various elements of the detector. We present the design of a time-to-digital converter (TDC) ASIC prototype for the…

Instrumentation and Detectors · Physics 2018-03-14 Jinhong Wang , Yu Liang , Xiong Xiao , Qi An , John W. Chapman , Tiesheng Dai , Bing Zhou , Junjie Zhu , Lei Zhao

This work summarizes the design, construction, initial performance evaluation and pilot clinical results of the IMAS system, a long axial field of view (FOV), also known as total-body (TB-), positron emission tomography (PET) prototype…

An integrate-and-fire time-encoding machine (IF-TEM) is an effective asynchronous sampler that translates amplitude information into non-uniform time sequences. In this work, we propose a novel Adaptive IF-TEM (AIF-TEM) approach. This…

Signal Processing · Electrical Eng. & Systems 2026-03-18 Aseel Omar , Alejandro Cohen

In the scope of the COMPASS experiment a multi-purpose, high rate capable TDC with digitisation width of 60 ps has been developed. The integration into the readout system and the flexible input of the CATCH readout driver is presented.

High Energy Physics - Experiment · Physics 2014-11-17 H. Fischer , J. Franz , A. Grunemaier , F. H. Heinsius , L. Hennig , K. Konigsmann , M. Niebuhr , T. Schmidt , H. Schmitt , H. J. Urban

The bistatic Integrated Sensing and Communication (ISAC) is poised to become a key application for next generation communication networks (e.g., B5G/6G), providing simultaneous sensing and communication services with minimal changes to…

Signal Processing · Electrical Eng. & Systems 2025-07-15 Yi Wang , Keke Zu , Luping Xiang , Martin Haardt , Kun Yang

Recently, a new precoding technique called orthogonal time-frequency signaling (OTFS) has been proposed for time- and frequency-selective communication channels. OTFS precodes a data frame with a complete set of spreading sequences and…

Information Theory · Computer Science 2017-10-30 Thomas Zemen , Markus Hofer , David Loeschenbrand

The need for wireless communication has driven the communication systems to high performance. However, the main bottleneck that affects the communication capability is the Fast Fourier Transform (FFT), which is the core of most modulators.…

Signal Processing · Electrical Eng. & Systems 2018-08-09 Rozita Teymourzadeh , Yazan Samir , Masuri Othman , Mok Vee Hong

The aim of this work is to develop high precision Time-of-Flight (TOF) devices based on high refractive index solid Cherenkov radiators read out by silicon photomultipliers (SiPMs). Cherenkov light is prompt and therefore ideal for reaching…

We present the design and characterization of TIGER (Turin Integrated Gem Electronics for Readout), a 64-channel ASIC developed for the readout of the CGEM (Cylindrical Gas Electron Multiplier) detector, the proposed inner tracker for the…