Related papers: Ionization Efficiency Study for Low Energy Nuclear…
We analyzed the response of NaI(Tl) to low energy nuclear recoils in the experiment that is reported on here. Such detectors have been used recently to search for evidence of dark matter in the form of weakly interacting massive particles…
We extend the study of the performance of a prototype two-phase liquid xenon WIMP dark matter detector to recoil energies below 20 keV. We demonstrate a new method for obtaining the best estimate of the energies of events using a calibrated…
Low-ionization metal absorption lines provide a primary probe of cool gas in and around galaxies. We confront observations of metal-line absorption in quasar spectra with predictions from the IllustrisTNG cosmological simulation in order to…
We report a systematic determination of the responses of PandaX-II, a dual phase xenon time projection chamber detector, to low energy recoils. The electron recoil (ER) and nuclear recoil (NR) responses are calibrated, respectively, with…
Accurate calculations of the nuclear recoil effect to the Lamb shift of hydrogen-like atoms are presented. Numerical results are reported for the $ns$ states with $n \leq 5$ and for the $2p_{1/2}$ and $2p_{3/2}$ states. The calculations are…
We have developed a transferable nonorthogonal tight-binding total energy model for germanium and use it to study small clusters. The cohesive energy, bulk modulus, elastic constants of bulk germanium can be described by this model to…
Given that there are 94 clinics and more than 200,000 patients treated worldwide, proton and carbon are the most used heavily charged particles in heavy ion therapy. However, there is a recent increasing trend in using new ion beams. Each…
The nuclear recoil effect on the g factor of highly charged Li-like ions is evaluated in the range Z=10-92. The calculations are performed using the 1/Z perturbation theory. The one-electron recoil contribution is evaluated within the fully…
A global analysis of the world data on differential cross sections and polarization asymmetries of backward pion-nucleon scattering for invariant collision energies above 3 GeV is performed in a Regge model. Including the $N_\alpha$,…
A new type of radiation detector, a p-type modified electrode germanium diode, is presented. The prototype displays, for the first time, a combination of features (mass, energy threshold and background expectation) required for a…
We show for the first time that the quenching of electronic excitation from nuclear recoils in liquid xenon is well-described by Lindhard theory, if the nuclear recoil energy is reconstructed using the combined (scintillation and…
New measurements and reaction model calculations are reported for single neutron pickup reactions onto a fast \nuc{22}{Mg} secondary beam at 84 MeV per nucleon. Measurements were made on both carbon and beryllium targets, having very…
Ab initio calculations of the Gamow-Teller (GT) matrix elements in the $\beta$ decays of $^6$He and $^{10}$C and electron captures in $^7$Be are carried out using both variational and Green's function Monte Carlo wave functions obtained…
We have measured the 6s - 7p_{1/2,3/2} transition probabilities in atomic cesium using a direct absorption technique. We use our result plus other previously measured transition rates to derive an accurate value of the vector transition…
Characterizing low-energy, keV-range nuclear recoils near the detector threshold is one of the major challenges for large direct dark matter detectors. To that end, we have successfully used a Yttrium-Beryllium photoneutron source that…
The energy loss and energy loss straggling widths have been measured in transmission for MeV protons traversing a thin kapton polyimide foil. In a prior step, the thickness and non-uniformity of the target foil were carefully investigated.…
We present results from the first deployment of novel, high definition, compact gas Time Projection Chambers (TPCs) with pixel chip readout as part of the BEAST II beam background measurement project at SuperKEKB. The TPCs provide detailed…
The emission of $\gamma$-rays after a neutron capture in a cryogenic detector can generate mono-energetic nuclear recoils in the sub-keV regime, of direct interest for the calibration of Dark Matter and Coherent Elastic Neutrino Nucleus…
The effect of finite nuclear mass on the magnetic-dipole transition probabilities between fine-structure levels of the same term is investigated. Based on a rigorous QED approach a nonrelativistic formula for the recoil correction to first…
MIMAC (MIcro-TPC MAtrix of Chambers) is a directional WIMP Dark Matter detector project. Direct dark matter experiments need a high level of electron/recoil discrimination to search for nuclear recoils produced by WIMP-nucleus elastic…