Related papers: Luminosity measurement at ILC
In $\rm e^+ \rm e^-$ collisions, the integrated luminosity is generally measured from the rate of low-angle Bhabha interactions $\rm e^+ e^- \to e^+ e^- $. In the published LEP results, the inferred theoretical uncertainty of $\pm 0.061\%$…
Two special calorimeters are foreseen for the instrumentation of the very forward region of the ILC detector, a luminometer designed to measure the rate of low angle Bhabha scattering events with a precision better than 10-3 and a low polar…
In this study, the sensitivity of future lepton colliders to WIMP dark matter is evaluated assuming WIMP pair production accompanied by a photon from initial state radiation, through which the process can be identified. A full detector…
Special calorimeters are needed to instrument the very forward region of an ILC detector. These devices will improve the hermeticity being important for new particle searches. A luminometer is foreseen to measure the rate of low angle…
This is the first of the series of papers which present a precision method of the day-by-day monitoring of the absolute LHC luminosity. The method is based on the measurement of the rate of coplanar lepton pairs produced in peripheral…
In $e^+ e^-$ collisions, electromagnetic effects caused by large charge density bunches modify the effective acceptance of the luminometer system of the experiments. These effects consequently bias the luminosity measurement from the rate…
Precision measurement of the stop mass at the ILC is done in a method based on cross-sections measurements at two different center-of-mass energies. This allows to minimize both the statistical and systematic errors. In the framework of the…
Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than…
Absolute normalisation of the LHC measurements with O(1%) precision and their relative normalisation, for the data collected at variable centre-of-mass energies, or for variable beam particle species, with O(0.1%) precision is crucial for…
The International Linear Collider (ILC) will collide polarised electrons and positrons at beam energies of 45.6 GeV to 250 GeV and optionally up to 500 GeV. To fully exploit the physics potential of this machine, not only the luminosity and…
The International Linear Collider (ILC) is a future electron/positron collider at the energy frontier. Its physics goals are clearly focused on precision measurements at the electroweak scale and beyond. Beam energy and beam polarisation…
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the…
The precision physics program of the ILC requires precise knowledge of the state of beam polarisation. In fact the Compton polarimeters intended for the ILC will have to measure the polarisation with error a factor of 2 smaller than the…
Beam position monitors (BPMs) are indispensable components of modern particle accelerators, providing real-time diagnostics to ensure precise beam control, stability, and quality. As accelerators such as the International Linear Collider…
Elastic light-by-light scattering, $\gamma\gamma\to\gamma\gamma$, can be measured in electromagnetic interactions of lead (Pb) ions at the Large Hadron Collider (LHC) and Future Circular Collider (FCC), using the large (quasi)real photon…
Future electron-positron ($\ee$) colliders, operating as Higgs factories or Z factories, promise unprecedented precision electroweak measurements that are vital to testing the Standard Model (SM) and exploring physics beyond it. Here we…
For cross section measurements, an accurate knowledge of the integrated luminosity is required. The FCC-ee Z lineshape programme sets the ambitious precision goal of $10^{-4}$ on the \emph{absolute} luminosity measurement and one order of…
Measurements of luminosity obtained using the ATLAS detector during early running of the Large Hadron Collider (LHC) at sqrt(s) = 7 TeV are presented. The luminosity is independently determined using several detectors and multiple…
A precise determination of absolute luminosity, using the bremsstrahlung process, at the future Electron-Ion Collider (EIC) will be very demanding, and its three major challenges are discussed herein. First, the bremsstrahlung rate…
We present results from luminosity, energy and polarization studies at a future Linear Collider. We compare e+e- and e-e- modes of operation and consider both NLC and TESLA beam parameter specifications at a center-of-mass energy of 500…