English
Related papers

Related papers: Light output response of the LVD liquid scintillat…

200 papers

For the development of liquid argon dark matter detectors we assembled a setup in the laboratory to scatter neutrons on a small liquid argon target. The neutrons are produced mono-energetically (E_kin=2.45 MeV) by nuclear fusion in a…

Instrumentation and Methods for Astrophysics · Physics 2013-03-12 C. Regenfus , Y. Allkofer , C. Amsler , W. Creus , A. Ferella , J. Rochet , M. Walter

Scintillator doped with a high neutron-capture cross-section material can be used to detect neutrons via their resulting gamma rays. Examples of such detectors using liquid scintillator have been successfully used in high-energy physics…

Instrumentation and Detectors · Physics 2019-01-01 D. M. Poehlmann , D. Barker , H. Chagani , P. Cushman , G. Heuermann , A. Medved , H. E. Rogers , R. Schmitz

We investigate scintillation linearity of a commercial high pressure $^4$He gas detector using monoenergetic 2.8 MeV neutrons from a deuterium-deuterium fusion neutron generator. The scintillation response of the detector was measured for a…

Instrumentation and Detectors · Physics 2019-10-23 A. Biekert , S. A. Hertel , E. Huebler , J. Lin , H. D. Pinckney , R. K. Romani , A. Serafin , V. Velan , D. N. McKinsey

Scintillation and ionisation yields for nuclear recoils in liquid xenon above 10 keVnr (nuclear recoil energy) are deduced from data acquired using broadband Am-Be neutron sources. The nuclear recoil data from several exposures to two…

We developed a 12-liter volume neutron detector filled with the liquid scintillator EJ301 that measures neutrons in an underground laboratory where dark matter and neutrino experiments are located. The detector target is a cylindrical…

Instrumentation and Detectors · Physics 2015-06-15 C. Zhang , D. -M. Mei , P. Davis , B. Woltman , F. Gray

The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota. A calibration of nuclear recoils in liquid xenon was…

Instrumentation and Detectors · Physics 2016-10-27 LUX Collaboration , D. S. Akerib , S. Alsum , H. M. Araújo , X. Bai , A. J. Bailey , J. Balajthy , P. Beltrame , E. P. Bernard , A. Bernstein , T. P. Biesiadzinski , E. M. Boulton , A. Bradley , R. Bramante , P. Brás , D. Byram , S. B. Cahn , M. C. Carmona-Benitez , C. Chan , J. J. Chapman , A. A. Chiller , C. Chiller , A. Currie , J. E. Cutter , T. J. R. Davison , L. de Viveiros , A. Dobi , J. E. Y. Dobson , E. Druszkiewicz , B. N. Edwards , C. H. Faham , S. Fiorucci , R. J. Gaitskell , V. M. Gehman , C. Ghag , K. R. Gibson , M. G. D. Gilchriese , C. R. Hall , M. Hanhardt , S. J. Haselschwardt , S. A. Hertel , D. P. Hogan , M. Horn , D. Q. Huang , C. M. Ignarra , M. Ihm , R. G. Jacobsen , W. Ji , K. Kamdin , K. Kazkaz , D. Khaitan , R. Knoche , N. A. Larsen , C. Lee , B. G. Lenardo , K. T. Lesko , A. Lindote , M. I. Lopes , D. C. Malling , A. Manalaysay , R. L. Mannino , M. F. Marzioni , D. N. McKinsey , D. M. Mei , J. Mock , M. Moongweluwan , J. A. Morad , A. St. J. Murphy , C. Nehrkorn , H. N. Nelson , F. Neves , K. O'Sullivan , K. C. Oliver-Mallory , K. J. Palladino , M. Pangilinan , E. K. Pease , P. Phelps , L. Reichhart , C. A. Rhyne , S. Shaw , T. A. Shutt , C. Silva , M. Solmaz , V. N. Solovov , P. Sorensen , S. Stephenson , T. J. Sumner , M. Szydagis , D. J. Taylor , W. C. Taylor , B. P. Tennyson , P. A. Terman , D. R. Tiedt , W. H. To , M. Tripathi , L. Tvrznikova , S. Uvarov , J. R. Verbus , R. C. Webb , J. T. White , T. J. Whitis , M. S. Witherell , F. L. H. Wolfs , J. Xu , K. Yazdani , S. K. Young , C. Zhang

We perform a theoretical study of the scintillation efficiency in the low-energy region crucial for liquid-xenon dark-matter detectors. We develop a computer program to simulate the cascading process of the recoiling xenon nucleus in liquid…

Instrumentation and Detectors · Physics 2013-10-10 Wei Mu , Xiaonu Xiong , Xiangdong Ji

The electron antineutrino spectrum in the Stereo reactor experiment (ILL Grenoble) is measured via the inverse beta decay signals in an organic liquid scintillator. The six target cells of the Stereo detector are filled with about 1800…

Instrumentation and Detectors · Physics 2019-01-30 Christian Buck , Benjamin Gramlich , Manfred Lindner , Christian Roca , Stefan Schoppmann

The study of the neutron response and n-gamma discrimination for small (18x26x8) mm3 liquid scintillator BC501A (Bicron) detector was carried out by digital charge comparison method. Three ranges of neutron energies were used: uniform…

Nuclear Experiment · Physics 2016-08-16 J. Černý , Z. Doležal , M. P. Ivanov , E. S. Kuzmin , J. Švejda , I. Wilhelm

The proton light yield of liquid scintillators is an important property in the context of their use in large-scale neutrino experiments, with direct implications for neutrino-proton scattering measurements and the discrimination of fast…

Instrumentation and Detectors · Physics 2023-03-01 E. J. Callaghan , B. L. Goldblum , J. A. Brown , T. A. Laplace , J. J. Manfredi , M. Yeh , G. D. Orebi Gann

Experiments searching for weak interacting massive particles with noble gases such as liquid argon require very low detection thresholds for nuclear recoils. A determination of the scintillation efficiency is crucial to quantify the…

Instrumentation and Detectors · Physics 2015-09-02 W. Creus , Y. Allkofer , C. Amsler , A. D. Ferella , J. Rochet , L. Scotto-Lavina , M. Walter

In order to develop a high spatial resolution (micron level) thermal neutron detector, a detector assembly composed of cerium doped lithium glass microfibers, each with a diameter of 1\,$\mu$m, is proposed, where the neutron absorption…

Instrumentation and Detectors · Physics 2016-06-14 Song Yushou , Joseph Conner , Xiaodong Zhang , Jason P. Hayward

We present a measurement of scintillation efficiency for a few tens of keV nuclear recoils (NR) with a liquid argon time projection chamber under electric fields ranging from $0$ to $3\ {\rm kV/cm}$. The calibration data are taken with…

Instrumentation and Detectors · Physics 2019-08-08 M. Kimura , M. Tanaka , T. Washimi , K. Yorita

For reactor neutrino experiments including the next--generation experiments will be adopting the liquid scintillator technique, criteria and time to select neutrino--induced inverse beta decay events from the background events need to be…

High Energy Physics - Experiment · Physics 2019-07-15 Chang Dong Shin , Kyung Kwang Joo , Dong Ho Moon , June Ho Choi , Myoung Youl Pac , Junghwan Goh

We characterized the light output response of a new 140 cm3 stilbene-d12 crystal up to 14.1 MeV neutron energies using a coincidence neutron scattering system. We also characterized its light output response to alpha particles in the 5 to…

Instrumentation and Detectors · Physics 2022-02-09 J. Zhou , N. Gaughan , F. D. Becchetti , R. O. Torres-Isea , M. Febbraro , N. Zaitseva , A. Di Fulvio

The feasibility of an ultra-low energy nuclear-recoil measurement in liquid xenon using neutron capture is investigated for a small (sub-kilogram) liquid xenon detector that is optimized for a high scintillation gain, and a pulsed neutron…

Instrumentation and Detectors · Physics 2022-10-20 C. S. Amarasinghe , R. Coronel , D. Q. Huang , Y. Liu , M. Arthurs , S. Steinfeld , R. Gaitskell , W. Lorenzon

Liquid xenon is an important detection medium in direct dark matter experiments, which search for low-energy nuclear recoils produced by the elastic scattering of WIMPs with quarks. The two existing measurements of the relative…

A fast neutron spectrometer consisting of segmented plastic scintillator and He-3 proportional counters was constructed for the measurement of neutrons in the energy range 1 MeV to 200 MeV. We discuss its design, principles of operation,…

Instrumentation and Detectors · Physics 2014-11-24 T. J. Langford , C. D. Bass , E. J. Beise , H. Breuer , D. K. Erwin , C. R. Heimbach , J. S. Nico

Alpha from natural radioactivity may interact with a nucleus and emit a neutron. The reaction introduces background to the liquid scintillator (LS) based neutrino experiments. In the LS detector, alpha comes from 238U, 232Th and 210Po decay…

Instrumentation and Detectors · Physics 2014-02-13 Jie Zhao , Zeyuan Yu , Jianglai Liu , Xiaobo Li , Feihong Zhang , Dongmei Xia