Related papers: DEPFET Pixels as a Vertex Detector for the Belle I…
Significant progress has been made to develop silicon pixel technologies for use in the vertex and tracker regions of the proposed Compact Linear Collider (CLIC) detector design. The electron-positron collisions generated by this linear…
A novel approach for designing the next generation of vertex detectors foresees to employ wafer-scale sensors that can be bent to truly cylindrical geometries after thinning them to thicknesses of 20-40$\mu$m. To solidify this concept, the…
The CERN proposed $e^+e^-$ Future Circular Collider (FCC-ee) is an electroweak, flavour, Higgs and top factory with unprecedented luminosities. Many measurements at the FCC-ee will rely on precisely determining the particle production…
SuperKEKB is the e-/e+ collider which targets the world highest luminosity. In recent operation, SuperKEKB achieved a new world record of $4.71\times 10^{34} cm^{-2}s^{-1}$ for luminosity with the beam current of 1.4 A. In the future, the…
A search for the flavor-changing neutral-current decay $B^{+}\to K^{+}\nu\bar{\nu}$ is performed at the Belle II experiment at the SuperKEKB asymmetric energy electron-positron collider. The results are based on a data sample corresponding…
From April to July 2018, a data sample at the peak energy of the $\Upsilon(4S)$ resonance was collected with the Belle~II detector at the SuperKEKB electron-positron collider. This is the first data sample of the Belle~II experiment. Using…
We present the result of a search for the charged-lepton-flavor violating decay $\tau^- \to \mu^-\mu^+\mu^-$ using a $424fb^{-1}$ sample of data recorded by the Belle II experiment at the SuperKEKB $e^{-}e^{+}$ collider. The selection of…
Test measurements on the silicon pixel detector for the beam trajectory monitor at the free electron laser of the TESLA test facility are presented. To determine the electronic noise of detector and read-out and to calibrate the signal…
The physics goals at the future e+e- linear collider require high performance vertexing and impact parameter resolution. Two possible technologies for the vertex detector of an experimental apparatus are outlined in the paper: an evolution…
A pixel detector with high spatial resolution and temporal information for ultra-cold neutrons is developed based on a commercial CCD on which a neutron converter is attached. 10B and 6Li are tested for the neutron converter and 10B is…
3D Silicon sensors fabricated at FBK-irst with the Double-side Double Type Column (DDTC) approach and columnar electrodes only partially etched through p-type substrates were tested in laboratory and in a 1.35 Tesla magnetic field with a…
The Lumped Element Kinetic Inductance Detectors (LEKID)demonstrated full maturity in the NIKA (New IRAM KID Arrays)instrument. These results allow directly comparing LEKID performance with other competing technologies (TES, doped silicon)…
Hybrid pixel sensor technology such as the Medipix3 represents a unique tool for electron imaging. We have investigated its performance as a direct imaging detector using a Transmission Electron Microscope (TEM) which incorporated a…
The R&D for a new type of liquid xenon (LXe) detector is ongoing to search for the neutrinoless double-beta decay ($0\nu2\beta$). As a result of the KamLAND-Zen experiment, it is very important to realize the all active region detector for…
We search for lepton-flavor-violating $\tau^-\to e^-\alpha$ and $\tau^-\to\mu^-\alpha$ decays, where $\alpha$ is an invisible spin-0 boson. The search uses electron-positron collisions at $10.58$ GeV center-of-mass energy with an integrated…
CMOS sensors were successfully implemented in the STAR tracker [1]. LHC experiments have shown that efficient b tagging, reconstruction of displaced vertices and identification of disappearing tracks are necessary. An improved vertex…
The physics aims at the proposed future CLIC high-energy linear $e^+ e^-$ collider pose challenging demands on the performance of the detector system. In particular the vertex and tracking detectors have to combine precision measurements…
In this note, we compile results of various simulation studies for the upgrade of the Belle detector. Based on these studies, we propose a set of optimum or appropriate parameters of the detector.
The High Luminosity upgrade of the CERN Large Hadron Collider will be able to reach a peak instantaneous luminosity of 5E34/cm2 s. The innermost detectors of the CMS and ATLAS experiments will have to cope with unprecedented requirements on…
LHCb is the dedicated heavy flavour experiment at the Large Hadron Collider at CERN. The partially assembled silicon vertex locator (VELO) of the LHCb experiment has been tested in a beam test. The data from this beam test have been used to…