English
Related papers

Related papers: Study of low frequency acoustic signals from super…

200 papers

Superheated drop detector (SDD) consisting of drops of superheated liquid of halocarbon is irradiated to neutrons and gamma-rays from 252Cf fission neutron source and 137Cs gamma source separately. The analysis of pulse height of the…

Instrumentation and Detectors · Physics 2014-11-21 Mala Das , S Seth , S Saha , S Bhattacharya , P Bhattacharjee

The superheated droplet detector (SDD) is known to be gamma insensitive below a threshold temperature which made them excellent candidates for neutron detection in the presence of gamma rays. Above the threshold temperature, the gamma ray…

Instrumentation and Detectors · Physics 2013-09-10 P. K. Mondal , B. K. Chatterjee

We report new results obtained in calibrations of superheated liquid droplet detectors used in dark matter searches with different radiation sources (n,$\alpha$,$\gamma$). In particular, detectors were spiked with alpha-emitters located…

Superheated Droplet Detectors (SDDs) are becoming commonplace in neutron personnel dosimetry. Their total insensitivity to minimum ionizing radiation (while responsive to nuclear recoils of energies ~ few keV), together with their low cost,…

Astrophysics · Physics 2008-02-03 J. I. Collar , T. A. Girard , D. Limagne , G. Waysand

Superheated drops are known to detect neutrons through the nucleation caused by the recoil nuclei produced by the interactions of neutrons with the atoms constituting the superheated liquid molecule. A novel method of finding the neutron…

Instrumentation and Detectors · Physics 2009-11-06 Mala Das , B. K. Chatterjee , B. Roy , S. C. Roy

R-134a (C2H2F4) is a low cost, easily available and chlorine free refrigerant, which in its superheated state can be used as an efficient neutron detector. Due to its high solubility in water the R-134a based superheated droplet detectors…

Instrumentation and Detectors · Physics 2014-03-28 Prasanna Kumar Mondal , Rupa Sarkar , Barun Kumar Chatterjee

DD and DT reaction rates may be compared to determine plasma temperatures in the 10--200 eV range. Distinguishing neutrons from these two reactions is difficult when yields are low or unpredictable. Time of flight methods fail if the source…

Instrumentation and Detectors · Physics 2014-06-11 J. I. Katz

A 30-g xenon bubble chamber, operated at Northwestern University in June and November 2016, has for the first time observed simultaneous bubble nucleation and scintillation by nuclear recoils in a superheated liquid. This chamber is…

Instrumentation and Detectors · Physics 2017-06-12 D. Baxter , C. J. Chen , M. Crisler , T. Cwiok , C. E. Dahl , A. Grimsted , J. Gupta , M. Jin , R. Puig , D. Temples , J. Zhang

The bubble nucleation in superheated liquid can be controlled by adjusting the ambient pressure and temperature. At higher pressure the threshold energy for bubble nucleation increases and we have observed that the amplitude of the acoustic…

Instrumentation and Detectors · Physics 2017-08-23 Rupa Sarkar , Prasanna Kumar Mondal , Barun Kumar Chatterjee

Superheated drops are known to vaporise when exposed to energetic nuclear radiation since the discovery of bubble chamber. As the degree of superheat increases in a given liquid, less and less energetic neutrons are required to cause…

Instrumentation and Detectors · Physics 2015-06-26 Mala Das , B. K. Chatterjee , B. Roy , S. C. Roy

We describe a system for interrogating the acoustic properties of sub-nanoliter liquid samples within an open microfluidics platform. Sessile droplets were deposited onto integrated optomechanical sensors, which possess…

Applied Physics · Physics 2023-07-17 Kyle G. Scheuer , Franz B. Romero , Graham J. Hornig , Ray G. DeCorby

Vaporization of low-boiling point droplets has numerous applications in combustion, process engineering and in recent years, in clinical medicine. However, the physical mechanisms governing the phase conversion are only partly explained.…

Fluid Dynamics · Physics 2021-02-24 Guilllaume Lajoinie , Tim Segers , Michel Versluis

Superheated droplets are proven to be excelent detectors for neutrons and could be used as a neutron dosimeter. To detect accurately the volume of the vapour formed upon nucleation and hence to observe the nucleation quantitatively an air…

Instrumentation and Detectors · Physics 2009-11-06 B. Roy , B. K. Chatterjee , Mala Das , S. C. Roy

We discuss the operation principle of a detector based on superheated droplets of Freon-12 and its feasibility for the search of weakly interacting cold dark matter particles. In particular we are interested in a neutralino search…

High Energy Physics - Experiment · Physics 2009-10-28 L. A. Hamel , L. Lessard , L. Rainville , B. Sur , V. Zacek

We report in situ neutron background measurements at the Kuo-Sheng Reactor Neutrino Laboratory (KSNL) by a hybrid neutron detector (HND) with a data size of 33.8 days under identical shielding configurations as during the neutrino physics…

We have measured the quasiparticle generation-recombination (GR) noise in aluminium lumped element kinetic inductors with a wide range of detector volumes at various temperatures. The basic detector consists of meandering inductor and…

Instrumentation and Methods for Astrophysics · Physics 2023-08-09 J. Li , P. S. Barry , T. Cecil , C. L. Chang , K. Dibert , R. Gualtieri , M. Lisovenko , Z. Pan , V. Yefremenko , G. Wang , J. Zhang

The PICASSO project is a cold dark matter (CDM) search experiment relying on the superheated droplet technique. The detectors use superheated freon liquid droplets (active material) dispersed and trapped in a polymerized gel. This detection…

A device filled with pure xenon first demonstrated the ability to operate simultaneously as a bubble chamber and scintillation detector in 2017. Initial results from data taken at thermodynamic thresholds down to ~4 keV showed sensitivity…

The next generation of radioactive ion beam facilities, which will give experimental access to many exotic nuclei, are presently being developed. These facilities will make it possible to study very short lived exotic nuclei with extreme…

Instrumentation and Detectors · Physics 2009-05-14 Pär-Anders Söderström

The PICASSO project is a cold dark matter (CDM) search experiment relying on the superheated droplet technique. The detectors use superheated freon liquid droplets (active material) dispersed and trapped in a polymerized gel. This detection…

‹ Prev 1 2 3 10 Next ›