English
Related papers

Related papers: Ba-ion extraction from a high pressure Xe gas for …

200 papers

An RF ion-funnel technique has been developed to extract ions from a high-pressure (10 bar) noble-gas environment into vacuum ($10^{-6}$ mbar). Detailed simulations have been performed and a prototype has been developed for the purpose of…

Neutrinoless double beta decay {($0\nu\beta\beta$)} provides a way to probe physics beyond the Standard Model of particle physics. The upcoming nEXO experiment will search for $0\nu\beta\beta$ decay in $^{136}$Xe with a projected half-life…

nEXO is a proposed experiment that will search for neutrinoless double-beta decay (0$\nu\beta\beta$) in 5-tonnes of liquid xenon (LXe), isotopically enriched in $^{136}$Xe. A technique called Ba-tagging is being developed as a potential…

EXO is a search for neutrinoless double beta decay in 136Xe. An active R&D program for a 10 ton, enriched 136Xe liquid phase detector is now underway. Current research projects are: decay product extraction, Xe purity studies, energy…

High Energy Physics - Phenomenology · Physics 2012-08-27 EXO Collaboration

Tagging barium ions in double beta decay experiments involving $^{136}$Xe offers a promising pathway to achieving an almost background-free environment, which is essential for addressing key unresolved questions in neutrino physics, such as…

Atomic Physics · Physics 2025-01-16 Álvaro Peralta Conde

The clustering and drift properties of barium ions in xenon gas are explored theoretically, using density functional theory and computational ion mobility theory, with the goal of better understanding barium ion transport for neutrinoless…

Instrumentation and Detectors · Physics 2018-08-14 E. Bainglass , B. J. P. Jones , F. W. Foss , M. N. Huda , D. R. Nygren

Searches for double beta decay of $^{134}$Xe were performed with EXO-200, a single-phase liquid xenon detector designed to search for neutrinoless double beta decay of $^{136}$Xe. Using an exposure of $29.6\text{ kg}\!\cdot\!\text{yr}$, the…

The design, construction, and performance of a linear radio-frequency ion trap (RFQ) intended for use in the Enriched Xenon Observatory (EXO) are described. EXO aims to detect the neutrinoless double-beta decay of $^{136}$Xe to $^{136}$Ba.…

The imaging of individual Ba$^{2+}$ ions in high pressure xenon gas is one possible way to attain background-free sensitivity to neutrinoless double beta decay and hence establish the Majorana nature of the neutrino. In this paper we…

Instrumentation and Detectors · Physics 2024-06-25 NEXT Collaboration , N. Byrnes , E. Dey , F. W. Foss , B. J. P. Jones , R. Madigan , A. McDonald , R. L. Miller , K. E. Navarro , L. R. Norman , D. R. Nygren , C. Adams , H. Almazán , V. Álvarez , B. Aparicio , A. I. Aranburu , L. Arazi , I. J. Arnquist , F. Auria-Luna , S. Ayet , C. D. R. Azevedo , J. E. Barcelon , K. Bailey , F. Ballester , M. del Barrio-Torregrosa , A. Bayo , J. M. Benlloch-Rodríguez , F. I. G. M. Borges , A. Brodolin , S. Cárcel , A. Castillo , S. Cebrián , E. Church , L. Cid , C. A. N. Conde , T. Contreras , F. P. Cossío , G. Díaz , T. Dickel , C. Echevarria , M. Elorza , J. Escada , R. Esteve , R. Felkai , L. M. P. Fernandes , P. Ferrario , A. L. Ferreira , Z. Freixa , J. García-Barrena , J. J. Gómez-Cadenas , R. González , J. W. R. Grocott , R. Guenette , J. Hauptman , C. A. O. Henriques , J. A. Hernando Morata , P. Herrero-Gómez , V. Herrero , C. Hervés Carrete , P. Ho , Y. Ifergan , F. Kellerer , L. Larizgoitia , A. Larumbe , P. Lebrun , F. Lopez , N. López-March , R. D. P. Mano , A. P. Marques , J. Martín-Albo , G. Martínez-Lema , M. Martínez-Vara , K. Mistry , J. Molina-Canteras , F. Monrabal , C. M. B. Monteiro , F. J. Mora , P. Novella , A. Nuñez , E. Oblak , J. Palacio , B. Palmeiro , A. Para , I. Parmaksiz , A. Pazos , J. Pelegrin , M. Pérez Maneiro , M. Querol , A. B. Redwine , J. Renner , I. Rivilla , C. Rogero , L. Rogers , B. Romeo , C. Romo-Luque , F. P. Santos , J. M. F. dos Santos , M. Seemann , I. Shomroni , P. A. O. C. Silva , A. Simón , S. R. Soleti , M. Sorel , J. Soto-Oton , J. M. R. Teixeira , S. Teruel-Pardo , J. F. Toledo , C. Tonnelé , J. Torrent , A. Trettin , A. Usón , P. R. G. Valle , J. F. C. A. Veloso , J. Waiton , A. Yubero-Navarro

The neutralization of slow positive ions on solid surfaces can lead to the emission of secondary electrons in Auger-type processes. We discuss the possibility of harnessing such mechanisms to the detection of positive ions in gaseous TPCs.…

Instrumentation and Detectors · Physics 2018-07-04 Lior Arazi

NEXT-DEMO is a 1:4.5 scale prototype of the NEXT100 detector, a high-pressure xenon gas TPC that will search for the neutrinoless double beta decay of $^{136}$Xe. X-ray energy depositions produced by the de-excitation of Xenon atoms after…

Instrumentation and Detectors · Physics 2019-08-13 L. Serra , D. Lorca , J. Martin-Albo , M. Sorel , J. J. Gomez-Cadenas

The NEXT collaboration is dedicated to the study of double beta decays of $^{136}$Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution ($\leq 1\%$ FWHM at…

Instrumentation and Detectors · Physics 2026-02-12 NEXT Collaboration , C. Adams , H. Almazán , V. Álvarez , A. I. Aranburu , L. Arazi , I. J. Arnquist , F. Auria-Luna , S. Ayet , Y. Ayyad , C. D. R. Azevedo , K. Bailey , F. Ballester , J. E. Barcelon , M. del Barrio-Torregrosa , A. Bayo , J. M. Benlloch-Rodríguez , F. I. G. M. Borges , A. Brodoline , N. Byrnes , A. Castillo , E. Church , L. Cid , M. Cid , X. Cid , C. A. N. Conde , C. Cortes-Parra , F. P. Cossío , R. Coupe , E. Dey , P. Dietz , C. Echeverria , M. Elorza , R. Esteve , R. Felkai , L. M. P. Fernandes , P. Ferrario , F. W. Foss , Z. Freixa , J. García-Barrena , J. J. Gómez-Cadenas , J. W. R. Grocott , R. Guenette , J. Hauptman , C. A. O. Henriques , J. A. Hernando Morata , P. Herrero-Gómez , V. Herrero , C. Hervés Carrete , Y. Ifergan , A. F. B. Isabel , B. J. P. Jones , F. Kellerer , L. Larizgoitia , A. Larumbe , P. Lebrun , F. Lopez , N. López-March , R. Madigan , R. D. P. Mano , A. Marauri , A. P. Marques , J. Martín-Albo , A. Martínez , G. Martínez-Lema , M. Martínez-Vara , R. L. Miller , K. Mistry , J. Molina-Canteras , F. Monrabal , C. M. B. Monteiro , F. J. Mora , K. E. Navarro , P. Novella , D. R. Nygren , E. Oblak , I. Osborne , J. Palacio , B. Palmeiro , A. Para , I. Parmaksiz , A. Pazos , J. Pelegrin , M. Pérez Maneiro , M. Querol , J. Renner , I. Rivilla , C. Rogero , L. Rogers , B. Romeo , C. Romo-Luque , E. Ruiz-Chóliz , P. Saharia , F. P. Santos , J. M. F. dos Santos , M. Seemann , I. Shomroni , A. L. M. Silva , P. A. O. C. Silva , A. Simón , S. R. Soleti , M. Sorel , J. Soto-Oton , J. M. R. Teixeira , S. Teruel-Pardo , J. F. Toledo , C. Tonnelé , S. Torelli , J. Torrent , A. Trettin , P. R. G. Valle , M. Vanga , P. Vázquez Cabaleiro , J. F. C. A. Veloso , J. D. Villamil , J. Waiton , A. Yubero-Navarro

The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber…

Instrumentation and Detectors · Physics 2022-02-23 N. Ackerman , J. Albert , M. Auger , D. J. Auty , I. Badhrees , P. S. Barbeau , L. Bartoszek , E. Baussan , V. Belov , C. Benitez-Medina , T. Bhatta , M. Breidenbach , T. Brunner , G. F. Cao , W. R. Cen , C. Chambers , B. Cleveland , R. Conley , S. Cook , M. Coon , W. Craddock , A. Craycraft , W. Cree , T. Daniels , L. Darroch , S. J. Daugherty , J. Daughhetee , C. G. Davis , J. Davis , S. Delaquis , A. Der Mesrobian-Kabakian , R. deVoe , T. Didberidze , J. Dilling , A. Dobi , A. G. Dolgolenko , M. J. Dolinski , M. Dunford , J. Echevers , L. Espic , W. Fairbank , D. Fairbank , J. Farine , W. Feldmeier , S. Feyzbakhsh , P. Fierlinger , K. Fouts , D. Franco , D. Freytag , D. Fudenberg , P. Gautam , G. Giroux , R. Gornea , K. Graham , G. Gratta , C. Hagemann , C. Hall , K. Hall , G. Haller , E. V. Hansen , C. Hargrove , R. Herbst , S. Herrin , J. Hodgson , M. Hughes , A. Iverson , A. Jamil , C. Jessiman , M. J. Jewell , A. Johnson , T. N. Johnson , S. Johnston , A. Karelin , L. J. Kaufman , R. Killick , T. Koffas , S. Kravitz , R. Krücken , A. Kuchenkov , K. S. Kumar , Y. Lan , A. Larson , D. S. Leonard , F. Leonard , F. LePort , G. S. Li , S. Li , Z. Li , C. Licciardi , Y. H. Lin , D. Mackay , R. MacLellan , M. Marino , J. -M. Martin , Y. Martin , T. McElroy , K. McFarlane , T. Michel , B. Mong , D. C. Moore , K. Murray , R. Neilson , O. Njoya , O. Nusair , K. O'Sullivan , A. Odian , I. Ostrovskiy , C. Ouellet , A. Piepke , A. Pocar , C. Y. Prescott , K. Pushkin , F. Retiere , A. Rivas , A. L. Robinson , E. Rollin , P. C. Rowson , M. P. Rozo , J. Runge , J. J. Russell , S. Schmidt , A. Schubert , D. Sinclair , K. Skarpaas , S. Slutsky , E. Smith , A. K. Soma , V. Stekhanov , V. Strickland , M. Swift , M. Tarka , J. Todd , T. Tolba , D. Tosi , T. I. Totev , R. Tsang , K. Twelker , B. Veenstra , V. Veeraraghavan , J. -L. Vuilleumier , J. -M. Vuilleumier , M. Wagenpfeil , A. Waite , J. Walton , T. Walton , K. Wamba , J. Watkins , M. Weber , L. J. Wen , U. Wichoski , M. Wittgen , J. Wodin , J. Wood , G. Wrede , S. X. Wu , Q. Xia , L. Yang , Y. -R. Yen , O. Ya Zeldovich , T. Ziegler

This article reviews the application of high pressure gas xenon (HPXe) time projection chambers to neutrinoless double beta decay experiments. First, the fundamentals of the technology and the historical development of the field are…

Instrumentation and Detectors · Physics 2019-03-07 J. J. Gomez-Cadenas , F. Monrabal , P. Ferrario

EXO-200 was a leading double beta decay experiment consisting of a single-phase, enriched liquid xenon time projection chamber filled with an admixture of 80.672% $^{136}$Xe and 19.098% $^{134}$Xe. The detector operated at WIPP between 2010…

The NEXT-100 detector will search for the neutrinoless double beta decay of $^{136}$Xe using an electroluminescent high-pressure xenon gas TPC filled with 100 kg of enriched Xe. An observation of this hypothetical process would establish a…

Instrumentation and Detectors · Physics 2019-08-13 D. Lorca

We present a new neutrinoless double beta decay concept: the high pressure selenium hexafluoride gas time projection chamber. Combining techniques pioneered in high pressure xenon gas such as topological discrimination, with the high…

Instrumentation and Detectors · Physics 2020-03-05 D. R. Nygren , B. J. P. Jones , N. Lopez-march , Y. Mei , F. Psihas , J. Renner
‹ Prev 1 2 3 10 Next ›