Related papers: Radiation damage in the LHCb Vertex Locator
The Vertex Locator (VELO) is a silicon microstrip detector that surrounds the proton-proton interaction region in the LHCb experiment. The performance of the detector during the first years of its physics operation is reviewed. The system…
LHCb is an experiment dedicated to the study of new physics in the decays of beauty and charm hadrons at the Large Hadron Collider (LHC) at CERN. The Vertex Locator (VELO) is the silicon detector surrounding the LHCb interaction point. The…
LHCb is a forward spectrometer experiment dedicated to the study of new physics in the decays of beauty and charm hadrons produced in proton collisions at the Large Hadron Collider (LHC) at CERN. The VErtex LOcator (VELO) is the microstrip…
The Upgrade II of the LHCb detector, foreseen for 2031, will operate at an instantaneous luminosity of 1.5 x 10$^{34}$ cm$^{-2}$s$^{-1}$, accumulating a sample of more than 300 fb$^{-1}$. To cope with the estimated pile-up of 42 and 200…
The upgrade of the LHCb experiment, scheduled for LHC Run-III, scheduled to start in 2021, will transform the experiment to a trigger-less system reading out the full detector at 40 MHz event rate. All data reduction algorithms will be…
An extensive sensor testing campaign is presented, dedicated to measuring the charge collection properties of prototype candidates for the Vertex Locator (VELO) detector for the upgraded LHCb experiment. The charge collection is measured…
The Large Hadron Collider beauty (LHCb) detector is designed to detect decays of b- and c- hadrons for the study of CP violation and rare decays. At the end of the LHC Run 2, many of the LHCb measurements remained statistically dominated.…
LHCb is the dedicated heavy flavour experiment at the Large Hadron Collider at CERN. The partially assembled silicon vertex locator (VELO) of the LHCb experiment has been tested in a beam test. The data from this beam test have been used to…
The high voltage system supplies the bias voltage to the 88 silicon sensors which comprise the LHCb Vertex Locator (VELO). This note describes the results of the tests which have been performed on the hardware of the high voltage system of…
A significant upgrade of the LHCb detector is scheduled to be installed in 2018-2019. Afterwards all sub-detectors will be read out at the LHC bunch crossing frequency of 40 MHz and the trigger will be fully implemented in software. The…
The thermal properties of the LHCb Vertex Locator (VELO) are studied using the real-time detector alignment procedure. The variation of the position and orientation of the detector elements as a function of the operating temperature of the…
The LHCb experiment is set for a significant upgrade, which will be ready for Run 3 of the LHC in 2020. This upgrade will allow LHCb to run at a significantly higher instantaneous luminosity and collect an integrated luminosity of…
The LHCb detector has undergone a major upgrade for LHC Run 3. This Upgrade I detector facilitates operation at higher luminosity and utilises full-detector information at the LHC collision rate, critically including the use of vertex…
LHCb will commence data taking as the first dedicated heavy flavour experiment at a hadron collider in 2008. A very high hit precision from its vertex detector (VELO) is essential to meet the tight requirements of vertex reconstruction in…
LHCb is one of the four main experiments of the Large Hadron Collider (LHC) project, which will start at CERN in 2008. The experiment is primarily dedicated to B-Physics and hence requires precise vertex reconstruction. The silicon vertex…
A comprehensive study of the spatial resolution and detection efficiency of sensor prototypes developed for the LHCb VELO upgrade is presented. Data samples were collected at the CERN SPS H8 beam line using a hadron mixture of protons and…
The data acquisition system of the upgraded LHCb experiment includes the fast reconstruction of all hits in the vertex locator (VELO) pixel detector at the beam-crossing rate of 40 MHz, implemented as on-the-fly clustering embedded in the…
The silicon strip sensors of the Belle II silicon vertex detector were irradiated with 90 MeV electron beams up to an equivalent 1-MeV-neutron fluence of $3.0\times 10^{13}~{\rm n}_{\rm eq}/{\rm cm^2}$. We measure changes in sensor…
The extreme radiation dose received by vertex detectors at the Large Hadron Collider dictates stringent requirements on their cooling systems. To be robust against radiation damage, sensors should be maintained below -20 degree C and at the…
The LHCb Vertex Locator contains 42 silicon sensor modules. Each module has two silicon sensors. A method for determining the relative alignment of the silicon sensors within each module from data is presented. The software implementation…