English
Related papers

Related papers: Ultrasensitive magnetic field detection using a si…

200 papers

Electron spins in solids constitute remarkable quantum sensors. Individual defect centers in diamond were used to detect individual nuclear spins with nanometer scale resolution, and ensemble magnetometers rival SQUID and vapor cell…

Cascades from high-energy particles produce a brief current and associated magnetic fields. Even sub-nanosecond duration magnetic fields can be detected with a relatively low bandwidth system by latching image currents on a capacitor. At…

Instrumentation and Detectors · Physics 2015-05-26 David Saltzberg , Peihao Sun

Fields with frequencies below megahertz are challenging for Rydberg-atom-based measurements, due to the low-frequency electric field screening effect that is caused by the alkali-metal atoms adsorbed on the inner surface of the container.…

Atomic Physics · Physics 2024-05-09 Mingwei Lei , Meng Shi

We use an optical cavity to detect single atoms magnetically trapped on an atom chip. We implement the detection using both fluorescence into the cavity and reduction in cavity transmission due to the presence of atoms. In fluorescence, we…

Other Condensed Matter · Physics 2009-11-11 Igor Teper , Yu-Ju Lin , Vladan Vuletic

Quantum sensing is an ever-evolving research field describing the use of a quantum phenomenon to perform measurement of a physical quantity. Amongst different types of quantum sensors, atomic vapor-based quantum effects are extensively used…

Atomic Physics · Physics 2023-07-13 Kfir Levi , Avital Giat , Liran Golan , Eliran Talker , Liron Stern

Optical magnetometers are currently able to achieve magnetometric sensitivities below 1 fT/Hz^1/2. Although such sensitivities are typically obtained for ultra-low-field measurements, a group of optical magnetometers allows the detection of…

Atomic Physics · Physics 2015-06-03 Przemyslaw Wlodarczyk , Szymon Pustelny , Jerzy Zachorowski , Marcin Lipinski

We present a Rydberg atom-based microwave electric field sensor that achieves extended dynamic range and enhanced sensitivity across a broad bandwidth. By characterizing the Autler-Townes (AT) splitting induced by a single-tone microwave…

Atomic Physics · Physics 2026-01-28 Hsuan-Jui Su , Shao-Cheng Fang , Ting-An Li , Chen-Hao Chang , Yu-Chi Chen , Yi-Hsin Chen

We present a hybrid atomic sensor that realizes radio-frequency electric field detection with intrinsic field amplification and polarization selectivity for robust high-sensitivity field measurement. The hybrid sensor incorporates a passive…

Applied Physics · Physics 2018-08-20 David A. Anderson , Eric G. Paradis , Georg Raithel

We present a method of sensing AC magnetic fields. The method is based on the construction of a robust qubit by the application of continuous driving fields. Specifically, magnetic noise and power fluctuations of the driving fields do not…

Quantum Physics · Physics 2017-07-13 N. Aharon , M. Drewsen , A. Retzker

The ability to sensitively detect charges under ambient conditions would be a fascinating new tool benefitting a wide range of researchers across disciplines. However, most current techniques are limited to low-temperature methods like…

In cold atomic gases the interactions between the atoms are directly controllable through external magnetic fields. The magnetic field control is typically performed indirectly by stabilizing the current through a pair of Helmholtz coils,…

We study gradient magnetometry with an ensemble of atoms with arbitrary spin. We calculate precision bounds for estimating the gradient of the magnetic field based on the quantum Fisher information. For quantum states that are invariant…

Quantum Physics · Physics 2018-06-08 Iagoba Apellaniz , Inigo Urizar-Lanz , Zoltan Zimboras , Philipp Hyllus , Geza Toth

Sensitive magnetometers have been applied in a wide range of research fields, including geophysical exploration, bio-magnetic field detection, ultralow-field nuclear magnetic resonance, etc. Commonly, magnetometers are directly placed at…

Nitrogen vacancy (NV) centers in diamond have developed into a powerful solid-state platform for compact quantum sensors. However, high sensitivity measurements usually come with additional constraints on the pumping intensity of the laser…

Spectroscopic analysis of AC magnetic signal using diamond quantum magnetometry is a promising technique for inductive imaging. Conventional dynamic decoupling like XY8 provides a high sensitivity of an oscillating magnetic signal with…

Mesoscale and Nanoscale Physics · Physics 2020-07-15 Kosuke Mizuno , Hitoshi Ishiwata , Yuta Masuyama , Takayuki Iwasaki , Mutsuko Hatano

Sensing static or slowly varying magnetic fields with high sensitivity and spatial resolution is critical to many applications in fundamental physics, bioimaging and materials science. Several versatile magnetometry platforms have emerged…

Quantum Physics · Physics 2021-04-07 A. Ajoy , Y. X. Liu , P. Cappellaro

We study a novel millimetre-scale magnetic trap for ultracold atoms, in which the current carrying conductors can be situated outside the vacuum region, a few mm away from the atoms. This design generates a magnetic field gradient in excess…

An increasing number of experiments require the use of ultrasensitive nanomechanical resonators. Relevant examples are the investigation of quantum effects in mechanical systems [1] or the detection of exceedingly small forces as in…

Instrumentation and Detectors · Physics 2010-07-12 O. Usenko , A. Vinante , G. Wijts , T. H. Oosterkamp

Well controlled and highly stable magnetic fields are desired for a wide range of applications in physical research, including quantum metrology, sensing, information processing, and simulation. Here we introduce a low-cost hybrid assembly…

Quantum Physics · Physics 2018-12-21 Frederick Hakelberg , Philip Kiefer , Matthias Wittemer , Tobias Schaetz , Ulrich Warring

We utilize a homodyne detection technique to achieve a new sensitivity limit for atom-based, absolute radio-frequency electric field sensing of $\mathrm{5 \mu V cm^{-1} Hz^{-1/2} }$. A Mach-Zehnder interferometer is used for the homodyne…

Quantum Physics · Physics 2016-11-01 Santosh Kumar , Haoquan Fan , Harald Kübler , Jiteng Sheng , James P. Shaffer