Related papers: Reducing the effect of thermal noise in optical ca…
The frequency stability of a laser locked to an optical reference cavity is fundamentally limited by thermal noise in the cavity length. These fluctuations are linked to material dissipation, which depends both on the temperature of the…
We demonstrate an easy to manufacture, 25 mm long ultra-stable optical reference cavity for transportable photonic microwave generation systems. Employing a rigid holding geometry that is first-order insensitive to the squeezing force and a…
We present an approach to mitigate coating thermal noise in optical cavities by using multiple TEM spatial modes to readout and stabilize laser frequency. With optimal weightings we synthesize a wider sampling of the mirror surface,…
Thermal noise of optical reference cavities sets a fundamental limit to the frequency instability of ultra-stable lasers. Using Levin's formulation of the fluctuation-dissipation theorem we correct the analytical estimate for the spacer…
Higher-order mode locking has been proposed to reduce the thermal noise limit of reference cavities. By locking a laser to the HG02 mode of a 10-cm long all ULE cavity, and measure its performance with the three-cornered-hat method among…
Thermal noise of a mirror is one of the most important issues in high precision measurements such as gravitational-wave detection or cold damping experiments. It has been pointed out that thermal noise of a mirror with multi-layer coatings…
We present the design and realization of two reference cavities for ultra-stable lasers addressing narrow transitions in mixed-species (In+ / Yb+) Coulomb crystals. With a simple setup, we achieve a fractional frequency instability close to…
A fundamental limit to the sensitivity of optical interferometry is thermal noise that drives fluctuations in the positions of the surfaces of the interferometer's mirrors, and thereby in the phase of the intracavity field. Schemes for…
We study theoretically the internal thermal noise of a mirror coated on a plano-convex substrate. The comparison with a cylindrical mirror of the same mass shows that the effect on a light beam can be reduced by a factor 10, improving the…
Lasers stabilized to vacuum-gap Fabry-P\'erot optical reference cavities display extraordinarily low noise and high stability, with linewidths much less than 1 Hz. These lasers can expand into new applications and ubiquitous use with the…
Thermal fluctuations of different origin in the substrate and in the coating of optical mirrors produce phase noise in the reflected wave. This noise determines the ultimate stabilization capability of high-Q cavities used as a reference…
Crystalline optical cavities are the foundation of today's state-of-the-art ultrastable lasers. Building on our previous silicon cavity effort, we now achieve the fundamental thermal noise-limited stability for a 6 cm long silicon cavity…
Extraneous thermal motion can limit displacement sensitivity and radiation pressure effects, such as optical cooling, in a cavity-optomechanical system. Here we present an active noise suppression scheme and its experimental implementation.…
Thermal noise of optical cavities limits the accuracy of many experiments on precision laser spectroscopy and interferometry. The study of the physical properties of this noise opens opportunities for the creation of more stable cavities,…
The interrogation of an ultra-narrow clock transition of a single trapped ion for optical frequency metrology requires a laser stabilized to a couple of Hz per second with a linewidth of the same order of magnitude. Today, lasers in the…
An ultrastable optical reference cavity with re-entrant fused silica mirrors and a ULE spacer structure is designed through finite element analysis. The designed cavity has a low thermal noise limit of $1\times10^{-16}$ and a flexible zero…
Thermal noise of a mirror can be reduced by cold damping. The displacement is measured with a high-finesse cavity and controlled with the radiation pressure of a modulated light beam. We establish the general quantum limits of noise in cold…
Thermodynamically induced length fluctuations of high-reflectivity mirror coatings put a fundamental limit on sensitivity and stability of precision optical interferometers like gravitational wave detectors and ultra-stable lasers. The main…
Three-mode parametric instability is a threat to attaining design power levels in Advanced gravitational wave detectors. The first observation of three-mode parametric instability in a long optical cavity revealed that instabilities could…
We present a joint theoretical and experimental characterization of thermo-refractive noise in high quality factor ($Q$), small mode volume ($V$) optical microcavities. Analogous to well-studied stability limits imposed by Brownian motion…