Related papers: How to Measure Forces when the Atomic Force Micros…
Further improvements are made to the non-linear data analysis algorithm for the atomic force microscope [P. Attard, arXiv:1212.3019v2 (2012)]. The algorithm is required when there is curvature in the compliance region due to photo-diode…
The Transient Fluctuation Theorem is used to calibrate an Atomic Force Microscope by measuring the fluctuations of the work performed by a time dependent force applied between a collo{\"i}dal probe and the surface. From this measure one can…
Experimental methods and procedures required for precision measurements of the Casimir force are presented. In particular, the best practices for obtaining stable cantilevers, calibration of the cantilever, correction of thermal and…
Commercial atomic force microscopes usually use a four-segmented photodiode to detect the motion of the cantilever via laser beam deflection. This read-out technique enables to measure bending and torsion of the cantilever separately. A…
A common use for atomic force microscopy is to quantify local forces through tip-sample interactions between the probe tip and a sample surface. The accuracy of these measurements depends on the accuracy to which the cantilever spring…
The electric forces acting on an atomic force microscope tip in solution have been measured using a microelectrochemical cell formed by two periodically biased electrodes. The forces were measured as a function of lift height and bias…
Atomic force microscopy (AFM) is a powerful tool to investigate interaction forces at the micro and nanoscale. Cantilever stiffness, dimensions and geometry of the tip can be chosen according to the requirements of the specific application,…
A force measurement technique has been developed that utilizes a clamped fiber optic element both as a cantilever and as a highly sensitive probe of the static and dynamic displacement of a sample that is mounted near its free end. Light…
Various methods of force measurement with the Atomic Force Microscope (AFM) are compared for their ability to accurately determine the tip-surface force from analysis of the nonlinear cantilever motion. It is explained how intermodulation,…
Mechanical properties of biological samples have been imaged with a \textit{Force Feedback Microscope}. Force, force gradient and dissipation are measured simultaneously and quantitatively, merely knowing the AFM cantilever spring constant.…
An ongoing challenge in atomic force microscope (AFM) experiments is the quantitative measurement of cantilever motion. The vast majority of AFMs use the optical beam deflection (OBD) method to infer the deflection of the cantilever. The…
Atomically-resolved imaging and force measurements using the atomic force microscope (AFM) are performed most commonly in a frequency-modulation (FM) mode. This has led to spectacular results, including direct observation of the atomic…
A new method is introduced for calibrating lateral force as measured by an atomic force microscope (AFM), making use of both an interferometric detector and an optical beam detector on the same instrument. The method may be implemented…
Interatomic-force measurements are regularly performed using frequency-modulation atomic force microscopy. This requires conversion of the observed shift in the resonant frequency of a force-sensing cantilever, to the actual force…
A method to measure the viscosity of liquids at microscales is presented. It uses a thin glass fiber fixed on the tip of the cantilever of an extremely low noise Atomic Force Microscope (AFM), which accurately measures the cantilever…
Atomic Force Microscopy (AFM) methods utilizing resonant mechanical vibrations of cantilevers in contact with a sample surface have shown sensitivities as high as few picometers for detecting surface displacements. Such a high sensitivity…
Atomic force microscope (AFM) users often calibrate the spring constants of cantilevers using functionality built into individual instruments. This is performed without reference to a global standard, which hinders robust comparison of…
Atomic force microscopy is an important tool for characterizing surface acoustic waves, in particular for high frequencies, where the wavelength is too short to be resolved by laser interferometry. A caveat is, that the cantilever…
We consider the stochastic dynamics of an array of two closely spaced atomic force microscope cantilevers in a viscous fluid for use as a possible biomolecule sensor. The cantilevers are not driven externally, as is common in applications…
Frequency-modulation atomic force microscopy provides an outstanding precision of the measurement of chemical bonding forces. However, as the cantilever oscillates with an amplitude A that is usually on the order of atomic dimensions or…