Related papers: A Novel Self-supporting GEM-based Amplification St…
The Gas Electron Multiplier (GEM) detector is one of promising particle and radiation detectors that has been improved greatly from previous gas detectors. The improvement includes better spatial resolutions, higher detection rate…
Non destructive quality control of microstructures at the manufacturing stage is an important issue in the foreseen use of huge numbers of such gaseous detectors in the future high luminosity colliders. In this work we report on the use of…
The International Large Detector (ILD) --a detector concept for the International Linear Collider (ILC)-- foresees a Time Projection Chamber (TPC) as its main tracking detector. Currently, the R&D efforts for such a TPC focus on studies…
We constructed and operated a double phase (liquid-vapour) pure argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC) with a sensitive area of 10x10 cm$^2$ and up to 30 cm of drift length. The LEM is a macroscopic hole…
The CYGNO experiment aims to build a large ($\mathcal{O}(10)$ m$^3$) directional detector for rare event searches, such as nuclear recoils (NRs) induced by dark matter (DM), such as weakly interactive massive particles (WIMPs). The detector…
An imaging system for measuring the spatial distribtion of charged particle tracks in a low-pressure gas is presented. The method is based on an optically read out time projection chamber. Results of experiments with fast heavy ions are…
Gas Electron Multipliers (GEMs) can be produced in large foils and molded in different shapes. The possibility to create cylindrical layers has opened the opportunity to use such detector as internal tracker at collider experiments. One…
Optical readout of GEM based devices by means of high granularity and low noise CMOS sensors allows to obtain very interesting tracking performance. Space resolution of the order of tens of $\mu$m were measured on the GEM plane along with…
At NISER-IoP detector laboratory an initiative is taken to build and test Gas Electron Multiplier (GEM) detectors for ALICE experiment. The optimisation of the gas flow rate and the long-term stability test of the GEM detector are…
A new gas detector prototype for the upgrade of the focal plane detector of the MAGNEX large-acceptance magnetic spectrometer has been developed and tested in view of the NUMEN project. It has been designed to operate at low gas pressure…
Optical time projection chambers (OTPCs) are well suited for applications that require the highest spatial resolution for particle track reconstruction. The MIGDAL experiment uses a glass GEM-based OTPC and observes a systematic excess in…
We have constructed and tested a 2d position sensitive parallel-plate gas ionization chamber with scanned charge transfer readout. The scan readout method described here is based on the development of a new position dependent charge…
We have produced thick-foil and fine-pitch gas electron multipliers (GEMs) using a laser etching technique. To improve production yield we have employed a new material, Liquid Crystal Polymer, instead of polyimide as an insulator layer. The…
Gas electron multiplier (GEM) is widely used in modern gas detectors of ionizing radiation in experiments on high-energy physics at accelerators and in other fields of science. Typically the GEM devices are based on a dielectric foil with…
With the advancement of the accelerator systems and the requirements of high luminosity particle beams to reach different physics goals, detectors with good position resolution and high rate handling capability have become essential for…
The ALICE experiment at the Large Hadron Collider at CERN is upgrading its central tracking detector, the Time Projection Chamber (TPC). The installation is foreseen during the second long shutdown of the Large Hadron Collider. The upgrade…
In this paper we present results from a test of a small Liquid Argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). This detector concept provides a 3D-tracking and calorimetric device capable of charge amplification,…
The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light, ~0.4% X0, as required by the low energy of the…
Measuring the energy loss and mass of highly ionizing particles predicted by theories from beyond the Standard Model pose considerable challenges to conventional detection techniques. Such particles are predicted to experience energy loss…
The conventional readout method of the RPC detector uses two sets of orthogonal readout strips placed at the both sides of the gas gap to collect signals of opposite polarities to obtain space points. A new readout method utilizing the…