English
Related papers

Related papers: Studies on fast triggering and high precision trac…

200 papers

As part of the Compact Muon Solenoid experiment Phase-II upgrade program, new Resistive Plate Chambers will be installed in the forward region. High background conditions are expected in this region during the high-luminosity phase of the…

Instrumentation and Detectors · Physics 2020-06-02 Sabino Meola

The Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. This note presents results of the RPC detector uniformity and stability during the 2011 data…

A strip-readout parallel-plate avalanche counter (SR-PPAC) has been developed aiming at the high detection efficiency and good position resolution in high-intensity heavy-ion measurements. The performance was evaluated using 115 MeV/u…

Micro-TPC, a time projection chamber(TPC) with micro pixel chamber($\mu$-PIC) readout was developed for the detection of the three-dimensional fine(sub-m illimeter) tracks of charged particles. We developed a two-dimensional position…

High Energy Physics - Experiment · Physics 2009-11-10 Kentaro Miuchi , Hidetoshi Kubo , Tsutomu Nagayoshi , Atsuhiko Ochi , Reiko Orito , Atsushi Takada , Toru Tanimori , Masaru Ueno

A four-gap glass RPC with 0.3mm gap size was tested with hadron beam as a time-of-flight detector having a time resolution of ~ 100ps. A thickness of the detector together with front-end electronics is ~ 12mm. Results on time resolution…

High Energy Physics - Experiment · Physics 2007-05-23 V. Ammosov , V. Gapienko , A. Semak , V. Senko , Yu. Sviridov , V. Zaets , E. Usenko

The time resolution for several single gap (2 mm) prototype Resistive Plate Chambers (RPC) made of high resistive (bulk resistivity ~ 10^10 - 10^12 ohm cm), 2 mm thick matt finished bakelite paper laminates with silicone coating on the…

Instrumentation and Detectors · Physics 2015-05-13 S. Biswas , S. Bhattacharya , S. Bose , S. Chattopadhyay , S. Saha , Y. P. Viyogi

While in a triggered experiment the matching of the RPC transmission line impedance with the one of the front-end electronics is less critical, for a trigger-less data recording this becomes mandatory. As expected, impedance matching is not…

Instrumentation and Detectors · Physics 2017-08-10 D. Bartoş , M. Petriş , M. Petrovici , L. Rădulescu , V. Simion

A prototype of Multi-strip Multi-gap Resistive Plate chamber (MMRPC) with active area 40 cm $\times$ 20 cm has been developed at SINP, Kolkata. Detailed response of the developed detector was studied with the pulsed electron beam from ELBE…

We have developed multi-gap resistive plate chambers (MRPCs) with 2.5 x 200 cm2 readout strips for the time-of-flight (TOF) detector system of the LEPS2 experiment at SPring-8. These chambers consist of 2 stacks and 5 gas gaps per stack, in…

The CMS experiment, located at the CERN Large Hadron Collider, has a redundant muon system composed by three different detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region) and Resistive…

The Resistive Plate Chambers detector system at the CMS experiment at the LHC provides robustness and redundancy to the muon trigger. A total of 1056 double-gap chambers cover the pseudo-rapidity region < 1.6. The main detector parameters…

Instrumentation and Detectors · Physics 2016-05-31 Mehar Ali Shah

Resistive Plate Chambers (RPCs) are essential active media of large-scale experiments as part of the muon systems and (semi-)digital hadron calorimeters. Among the several outstanding issues associated with the RPCs, the loss of efficiency…

Instrumentation and Detectors · Physics 2023-07-19 Mehmet Tosun , Burak Bilki , Kutlu Kagan Sahbaz

We have demonstrated that small gap (0.1 to 0.4 mm) RPCs made of low resistivity materials (less than 1E8 Ohm.cm) can operate at counting rates of up to 1E5 Hz/mm2 with position resolutions better than 50 micrometer. Results of preliminary…

Instrumentation and Detectors · Physics 2009-11-07 T. Francke , P. Fonte , V. Peskov , J. Rantanen

The forward muon spectrometer of ALICE (A Large Ion Collider Experiment) is equipped with a trigger system made of four planes of Resistive Plate Chambers (RPC), arranged in two stations with two planes each, for a total area of about 140…

Instrumentation and Detectors · Physics 2012-11-09 Francesco Bossù , Martino Gagliardi , Massimiliano Marchisone , ALICE Collaboration

During Phase-2 of the LHC, known as the High Luminosity LHC (HL-LHC), the accelerator will increase its instantaneous luminosity to 5 $\times$ 10$^{34}$ cm$^{-2}$ s$^{-1}$, delivering an integrated luminosity of 3000 fb$^{-1}$ over 10 years…

Instrumentation and Detectors · Physics 2020-07-24 Priyanka Kumari

The Multigap Resistive Plate Chambers (MRPCs) are gas ionization detectors with multiple gas sub-gaps made of resistive electrodes. The high voltage (HV) is applied on the outer surfaces of outermost resistive plates only, while the…

Instrumentation and Detectors · Physics 2016-12-16 Moon Moon Devi , Naba K. Mondal , B. Satyanarayana , R. R. Shinde

To achieve high-resolution muography of compact targets in scenarios with complex logistical constraints, we are developing a portable muon detector system utilizing glass Resistive Plate Chambers (RPCs). Although RPCs are well understood…

The Multi-gap Resistive Plate Chamber (MRPC) is an advanced form of Resistive Plate Chamber (RPC) detector where the gas gap is divided into sub-gaps. MRPCs are known for their good time resolution and detection efficiency for charged…

Instrumentation and Detectors · Physics 2018-08-15 Rajesh Ganai , Mitali Mondal , Shaifali Mehta , Zubayer Ahammed , Subhasis Chattopadhyay

The phase-out of hydro-fluorocarbons, owing to their high Global Warming Power, affecting the main gas used in Resistive Plate Chambers (RPCs), tetrafluoroethane C$_2$H$_2$F$_4$, has increased operational difficulties on existing systems…

Instrumentation and Detectors · Physics 2024-03-01 A. Blanco , P. Fonte , L. Lopes , M. Pimenta

This paper has the purpose to study the rate capability of the Resistive Plate Chamber, RPC, starting from the basic physics of this detector. The effect of different working parameters determining the rate capability is analysed in detail,…

Instrumentation and Detectors · Physics 2016-08-03 G. Aielli , P. Camarri , R. Cardarelli , A. Di Ciaccio , L. Di Stante , R. Iuppa , B. Liberti , L. Paolozzi , E. Pastori , R. Santonico , M. Toppi