English
Related papers

Related papers: Micromegas-TPC operation at high pressure in xenon…

200 papers

We present in this work measurements performed with a small Micromegas-TPC using a xenon-trimethylamine (Xe-TMA) Penning-mixture as filling gas. Measurements of gas gain and energy resolutions for 22.1 keV X-rays are presented, spanning…

NEXT-MM is a general-purpose high pressure (10 bar, $\sim25$ l active volume) Xenon-based TPC, read out in charge mode with an 8 cm $\times$8 cm-segmented 700 cm$^2$ plane (1152 ch) of the latest microbulk-Micromegas technology. It has been…

The operational characteristics of a Micromegas operating in pure xenon at the pressure range of 1 to 10 bar are investigated. The maximum charge gain achieved in each pressure is approximately constant, around 4x10^2, for xenon pressures…

Instrumentation and Detectors · Physics 2011-02-11 C. Balan , E. D. C. Freitas , T. Papaevangelou , I. Giomataris , H. Natal da Luz , C. M. B. Monteiro , J. M. F. dos Santos

The latest Micromesh Gas Amplification Structures (Micromegas) are achieving outstanding energy resolution for low energy photons, with values as low as 11% FWHM for the 5.9 keV line of $^{55}$Fe in argon/isobutane mixtures at atmospheric…

Instrumentation and Detectors · Physics 2015-05-13 T. Dafni , E. Ferrer-Ribas , I. Giomataris , Ph. Gorodetzky , F. Iguaz , I. G. Irastorza , P. Salin , A. Tomas

We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When…

Micromegas is a type of micro-pattern gaseous detector currently under R&D for applications in rare event search experiments. Here we report the performance of a Micromegas structure constructed with a micromesh thermo-bonded to a readout…

Instrumentation and Detectors · Physics 2014-05-13 Yuehuan Wei , Liang Guan , Zhiyong Zhang , Qing Lin , Xiaolian Wang , Kaixuan Ni , Tianchi Zhao

The gaseous Xenon(Xe) time projection chamber (TPC) is an attractive detector technique for neutrinoless double beta decay and WIMP dark matter searches. While it is less dense compared to Liquid Xe detectors, it has intrinsic advantages in…

Instrumentation and Detectors · Physics 2016-04-13 Y. Nakajima , A. Goldshmidt , H. S. Matis , T. Miller , D. R. Nygren , C. A. B. Oliveira , J. Renner

We report on a systematic characterization of microbulk Micromegas readouts in high-pressure Ar+1%iC4H10 and Ne+2%iC4H10 mixtures. Experimental data on gain, electron transmission and energy resolution are presented for a wide range of…

Instrumentation and Detectors · Physics 2022-08-03 F. J. Iguaz , T. Dafni , C. Canellas , J. F. Castel , S. Cebrián , J. G. Garza , I. G. Irastorza , G. Luzón , H. Mirallas , E. Ruiz Chóliz

Liquid Xe TPCs are among the most popular choices for double beta decay and WIMP dark matter searches. Gaseous Xe has intrinsic advantages when compared to Liquid Xe, specifically, tracking capability and better energy resolution for double…

Instrumentation and Detectors · Physics 2015-05-15 Y. Nakajima , A. Goldschmidt , H. S. Matis , D. Nygren , C. Oliveira , J. Renner

The search for the neutrinoless double beta decay (0$\nu\beta\beta$) is one of the most important quests nowadays in neutrino physics. Among the different techniques used, high pressure xenon (HPXe) gas time projection chambers (TPC) stand…

Instrumentation and Detectors · Physics 2016-05-25 J. Galan

A technical description of NEXT-MM and its commissioning and first performance is reported. Having an active volume of ~35 cm drift $\times$ 28 cm diameter, it constitutes the largest Micromegas-read TPC operated in Xenon ever constructed,…

A high-pressure xenon gas time projection chamber, with a unique cellular readout structure based on electroluminescence, has been developed for a large-scale neutrinoless double-beta decay search. In order to evaluate the detector…

Double beta $\beta\beta$ decay experiments are one of the most active research topics in Neutrino Physics. The measurement of the neutrinoless mode $0\nu\beta\beta$ could give unique information on the neutrino mass scale and nature. The…

In the search for the neutrinoless double beta decay of $^{136}$Xe, a high pressure xenon time projection chamber (HPXe-TPC) has two advantages over liquid xenon TPCs: a better energy resolution and the access to topological features, which…

Instrumentation and Detectors · Physics 2017-10-11 F. J. Iguaz , F. Aznar , J. F. Castel , S. Cebrian , T. Dafni , J. Galan , J. G. Garza , I. G. Irastorza , G. Luzon , H. Mirallas , E. Ruiz-Choliz

AXEL is a high pressure xenon gas TPC detector being developed for neutrinoless double-beta decay search. We use the proportional scintillation mode with a new electroluminescence light detection system to achieve high energy resolution in…

Instrumentation and Detectors · Physics 2017-11-27 S. Ban , K. D. Nakamura , S. Akiyama , M. Hirose , A. K. Ichikawa , Y. Ishiyama , A. Minamino , K. Miuchi , T. Nakaya , H. Sekiya , S. Tanaka , K. Ueshima , S. Yanagita

Excellent energy resolution is one of the primary advantages of electroluminescent high pressure xenon TPCs, and searches for rare physics events such as neutrinoless double-beta decay ($\beta\beta0\nu$) require precise energy measurements.…

The aim of the presented work was to develop further techniques based on a Micromegas-TPC, in order to reach a high gas gain with good energy resolution, and to search for gas mixtures suitable for rare event detection. This paper focuses…

High Energy Physics - Experiment · Physics 2009-01-14 L. Ounalli , J-L. Vuilleumier , D. Schenker , J-M. Vuilleumier

NEXT-100 is a high-pressure xenon time projection chamber with electroluminescent amplification, designed to operate with up to approximately 70.5 kg at 13.5 bar. It is the most recent detector developed by the NEXT collaboration to search…

Instrumentation and Detectors · Physics 2026-01-13 NEXT Collaboration , M. Pérez Maneiro , M. Martínez-Vara , S. Torelli , G. Martínez-Lema , P. Novella , J. A. Hernando Morata , J. J. Gómez-Cadenas , C. Adams , H. Almazán , V. Álvarez , A. I. Aranburu , L. Arazi , I. J. Arnquist , F. Auria-Luna , S. Ayet , Y. Ayyad , C. D. R. Azevedo , K. Bailey , F. Ballester , J. E. Barcelon , M. del Barrio-Torregrosa , A. Bayo , J. M. Benlloch-Rodríguez , F. I. G. M. Borges , A. Brodoline , N. Byrnes , A. Castillo , E. Church , L. Cid , M. Cid , X. Cid , C. A. N. Conde , C. Cortes-Parra , F. P. Cossío , R. Coupe , E. Dey , P. Dietz , C. Echeverria , M. Elorza , R. Esteve , R. Felkai , L. M. P. Fernandes , P. Ferrario , F. W. Foss , Z. Freixa , J. García-Barrena , J. W. R. Grocott , R. Guenette , J. Hauptman , C. A. O. Henriques , P. Herrero-Gómez , V. Herrero , C. Hervés Carrete , Y. Ifergan , A. F. B. Isabel , B. J. P. Jones , F. Kellerer , L. Larizgoitia , A. Larumbe , F. Lopez , N. López-March , R. Madigan , R. D. P. Mano , A. Marauri , A. P. Marques , J. Martín-Albo , A. Martínez , R. L. Miller , K. Mistry , J. Molina-Canteras , F. Monrabal , C. M. B. Monteiro , F. J. Mora , K. E. Navarro , D. R. Nygren , E. Oblak , J. Palacio , B. Palmeiro , I. Parmaksiz , A. Pazos , J. Pelegrin , M. Querol , J. Renner , I. Rivilla , C. Rogero , L. Rogers , B. Romeo , C. Romo-Luque , E. Ruiz-Chóliz , P. Saharia , F. P. Santos , J. M. F. dos Santos , M. Seemann , I. Shomroni , A. L. M. Silva , P. A. O. C. Silva , A. Simón , S. R. Soleti , M. Sorel , J. Soto-Oton , J. M. R. Teixeira , S. Teruel-Pardo , J. F. Toledo , C. Tonnelé , J. Torrent , A. Trettin , P. R. G. Valle , M. Vanga , P. Vázquez Cabaleiro , J. F. C. A. Veloso , J. D. Villamil , J. Waiton , A. Yubero-Navarro

NEXT is a new experiment to search for neutrinoless double beta decay using a 100 kg radio-pure high-pressure gaseous xenon TPC. The detector requires excellent energy resolution, which can be achieved in a Xe TPC with electroluminescence…

Instrumentation and Methods for Astrophysics · Physics 2015-05-19 L. M. P. Fernandes , E. D. C. Freitas , M. Ball , J. J. Gómez-Cadenas , C. M. B. Monteiro , N. Yahlali , D. Nygren , J. M. F. dos Santos

In view of a possible application as a charge-particle track readout for an Active Target Time Projection Chamber (AT-TPC), the operating properties of THick Gaseous Electron Multipliers (THGEM) in pure low-pressure Helium were…

Instrumentation and Detectors · Physics 2015-06-23 Marco Cortesi , John Yurkon , Andreas Stolz
‹ Prev 1 2 3 10 Next ›