English
Related papers

Related papers: A Piggyback resistive Micromegas

200 papers

Due to their simplicity and versatility of design, straight strip or rectangular pad anode structures are frequently employed with micro-pattern gas detectors to reconstruct high precision space points for various tracking applications. The…

An innovative Cylindrical Gas Electron Multiplier (CGEM) detector is under construction for the upgrade of the inner tracker of the BESIII experiment. A novel system has been worked out for the readout of the CGEM detector, including a new…

A novel gaseous two-dimensional imaging detector "Micro Pixel Chamber (micro-PIC)" has been developed. This detector is based on double sided printed circuit board (PCB). We have developed large area (10cm x 10cm) micro-PICs with 65536…

High Energy Physics - Experiment · Physics 2015-06-25 T. Nagayoshi , H. Kubo , K. Miuchi , A. Ochi , R. Orito , A. Takada , T. Tanimori , M. Ueno

The MIDNA application specific integrated circuits (ASICs) are a series of skipper-CCD readout chips fabricated in a 65 nm low-power CMOS process that implement a correlated double sampling signal processing chain based on dual-slope…

The SALSA chip is a future readout ASIC foreseen for the MPGD detectors, developed in the framework of the EIC collider project, to equip the MPGD trackers of the EPIC experiment. It is designed to be versatile, to be adapted to other…

A detector with a profile-based cathode and a pad-strip cathode readout system is experimentally investigated. Cathode pads arranged along each anode wire are diagonally interconnected and form strips that cross the detector at an angle…

We present a novel approach to the readout of ionization detectors. The solution allows to minimize the number of components and the space occupation close to the detector. This way a minimal impact is added on the radioactive background in…

Instrumentation and Detectors · Physics 2015-05-27 C. Cattadori , B. Gallese , A. Giachero , C. Gotti , M. Maino , G. Pessina

The CMS collaboration is building a new inner tracking pixel detector for the High-Luminosity LHC. Each pixel readout chip will be controlled with a single serial input stream at 160 Mbps and will send out data via four current mode logic…

Instrumentation and Detectors · Physics 2022-09-07 Caleb Smith

This paper presents a novel pixel chip readout scheme: the Region-of-Interest Readout Circuit (ROIRC), which is designed for large area, large array pixel chips and Gas Pixel Detector (GPD). This design employs a sentinel pixel detection…

The innermost part of the ATLAS experiment at the LHC, CERN, will be a pixel detector. The command messages and the readout data of the detector are transmitted over an optical data path. The readout chain consists of many components which…

A front-end readout electronics system has been developed for silicon strip detectors. The system uses an application specific integrated circuit (ASIC) ATHED to realize multi-channel E&T measurement. The slow control of ASIC chips is…

Instrumentation and Detectors · Physics 2011-06-13 Yi Qian , Hong Su , Jie Kong , Cheng-Fu Dong , Xiao-Li Ma , Xiao-Gang Li

The multi-pad PICOSEC-Micromegas is an improved detector prototype with a segmented anode, consisting of 19 hexagonal pads. Detailed studies are performed with data collected in a muon beam over four representative pads. We demonstrate that…

We present the development of a single-photon detector and the connected read-out electronics. This `hybrid' detector is based on a vacuum tube, transmission photocathode, microchannel plate and a pixelated CMOS read-out anode encapsulating…

Instrumentation and Detectors · Physics 2022-07-06 J. A. Alozy , N. V. Biesuz , M. Campbell , V. Cavallini , A. Cotta Ramusino , M. Fiorini , M. Guarise , X. Llopart Cudie

Resistive-anode micromegas detectors are in development since several years, in an effort to solve the problem of sparks when working at high flux and high ionizing radiation like in the HL-LHC (up to ten times the luminosity of the LHC).…

Resistive-anode Micromegas detectors are in development since several years, in an effort to solve the problem of sparks when working in high flux and high radiations environment like in the HL-LHC (ten times the luminosity of the LHC).…

The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC. The recent Micromegas efforts towards building a large size detector will be described, in particular the characterization measurements of a…

A two-dimensional position-sensitive microchannel plate detector, with a {\O}100 mm sensitive area and equipped with four integrated amplifiers, is realized with a new anode scheme. The anode is constructed by two independent…

Instrumentation and Detectors · Physics 2018-08-01 Yuezhao Zhang , Deyang Yu , Junliang Liu , Liping Yang , Wei Wang , Xiaoxiao Li , Xiaona Zhu , Xiaoxun Song , Xinfei Hui , Wei Xi , Xin Li , Huiping Liu , Xiaohong Cai

We report on a recently developed novel type of large area (62 mm x 62 mm) position sensitive silicon detector with four-corner readout. It consists of a square-shaped ion-implanted resistive anode framed by additional low-resistivity…

Nuclear Experiment · Physics 2008-11-26 A. Banu , Y. Li , M. McCleskey , M. Bullough , S. Walsh , C. A. Gagliardi , L. Trache , R. E. Tribble , C. Wilburn

A new generation of Monolithic Active Pixel Sensors (MAPS), produced in a 65 nm CMOS imaging process, promises higher densities of on-chip circuits and, for a given pixel size, more sophisticated in-pixel logic compared to larger feature…