Related papers: Sub-femtotesla scalar atomic magnetometer using mu…
We demonstrate the sensitivity of a sensor based on an optically-pumped radio-frequency (RF) atomic magnetometer to the polarization state of the detected RF magnetic field, and measure $>$36 dB difference in amplitude sensitivity for…
The existence of cross-over resonances makes saturated-absorption spectra very complicated when external magnetic field B is applied. It is demonstrated for the first time that the use of micrometric-thin cells (MTC, $L\approx40\,\mu$m)…
Miniaturized atomic magnetometers, particularly spin-exchange relaxation-free atomic magnetometers, have been emerging in clinical imaging applications such magnetocardiography and magnetoencephalography. Miniaturization, portability, and…
We report the design and performance of a non-magnetic drift stable optically pumped cesium magnetometer with a measured sensitivity of 35 fT at 200 s integration time and stability below 50 fT between 70 s and 600 s. To our knowledge this…
Magnetic gradiometers have wide practical and academic applications, and two important types of field gradient observables are the total field gradient and field gradient tensor. However, measurements of the field gradient tensor have not…
Random motion of spins is usually detrimental in magnetic resonance experiments. The spin diffusion in non-uniform magnetic fields causes broadening of the resonance and limits the sensitivity and the spectral resolution in applications…
We present an experimental study of the intrinsic magnetometric sensitivity of an optical/rf-frequency double resonance magnetometer in which linearly polarized laser light is used in the optical pumping and detection processes. We show…
Precision sensing, and in particular high precision magnetometry, is a central goal of research into quantum technologies. For magnetometers, often trade-offs exist between sensitivity, spatial resolution, and frequency range. The…
Ultra-sensitive measurement of the magneto-optical rotation, due to interaction of linearly-polarized light passing through room-temperature Rb 85 atoms, in response to change in longitudinal magnetic field (\delta B_z ) is demonstrated…
We demonstrate that spin-exchange dephasing of Larmor precession at near-earth-scale fields is effectively eliminated by dressing the alkali-metal atom spins in a sequence of AC-coupled 2-pi pulses, repeated at the Larmor precession…
We report on a single-channel rubidium radio-frequency atomic magnetometer operating in un-shielded environments and near room temperature with a measured sensitivity of 130 fT/\sqrt{Hz}. We demonstrate consistent, narrow-bandwidth…
Optical magnetometers are currently able to achieve magnetometric sensitivities below 1 fT/Hz^1/2. Although such sensitivities are typically obtained for ultra-low-field measurements, a group of optical magnetometers allows the detection of…
In this work we demonstrate a high sensitivity atomic gradiometer capable of operation in earth-field level environments. We apply a light-pulse sequence at four times the Larmor frequency to achieve gradiometer sensitivity <20…
Noise properties of an idealized atomic magnetometer that utilizes spin squeezing induced by a continuous quantum nondemolition measurement are considered. Such a magnetometer measures spin precession of $N$ atomic spins by detecting…
We describe an array of spin-exchange relaxation free optical magnetometers designed for detection of fetal magnetocardiography (fMCG) signals. The individual magnetometers are configured with a small volume with intense optical pumping,…
Pump and probe scalar atomic magnetometers show incredible potential for real-world, traditionally difficult measurement environments due to their high dynamic range and linearity. Previously, it has been assumed these scalar magnetometer…
A self-oscillating magnetometer based on the nonlinear magneto-optical rotation effect with separate modulated pump and unmodulated probe beams is demonstrated. This device possesses a bandwidth exceeding $1\khz$. Pump and probe are…
We discuss techniques for probing the effects of a constant force acting on cold atoms using two configurations of a grating echo-type atom interferometer. Laser-cooled samples of $^{85}$Rb with temperatures as low as 2.4 $\mu$K have been…
An improved spatial magnetometer using a spinor Bose-Einstein condensate of $^{87}$Rb atoms is realized utilizing newly developed two-polarization phase contrast imaging. The optical shot noise is suppressed by carefully choosing the probe…
We have manufactured more than 250 nominally identical paraffin-coated Cs vapor cells (30 mm diameter bulbs) for multi-channel atomic magnetometer applications. We describe our dedicated cell characterization apparatus. For each cell we…