Related papers: Submicron multi-bunch BPM for CLIC
In frame of the development of a high resolution BPM system for the CLIC Main Linac we present the design of a cavity BPM prototype. It consists of a waveguide loaded dipole mode resonator and a monopole mode reference cavity, both…
An introduction and the status of R&D activities for a high-resolution, "cold" beam position monitor (BPM) and the related read-out electronics are discussed. Two different BPM detector concepts, to be attached to the SC quadrupole and…
The main physics programme of the International Linear Collider (ILC) requires a measurement of the beam energy at the interaction point with an accuracy of $10^{-4}$ or better. To achieve this goal a magnetic spectrometer using high…
Beam position monitors (BPMs) are indispensable components of modern particle accelerators, providing real-time diagnostics to ensure precise beam control, stability, and quality. As accelerators such as the International Linear Collider…
The current program at Fermilab involves the construction of a new superconducting linear accelerator (LINAC) to replace the existing warm version. The new LINAC, together with other planned improvements, is in support of proton beam…
The CLIC linear collider aims at accelerating multiple bunches of electrons and positrons and colliding them at a centre of mass energy of 3 TeV. These bunches will be accelerated through X-band linacs, operating at an accelerating…
The use of non-invasive sensors & systems to measure particle beam characteristics is a crucial part of modern accelerator control systems due to their ability to return real time passive measurements without impacting the beam quality.…
In order to pursue high-precision beam position measurements for the free-electron laser (FEL) facilities, cavity beam position monitor (CBPM) is employed to measure the transverse position which can meet the requirement of position…
A Buncher or Capture Cavity (BCC) Cryomodule is currently in development at Fermilab for use in a second injector for LCLS-II-HE. The BCC Cryomodule is designed to contain one 1.3 GHz cavity and one solenoid magnet as part of a 100MeV low…
The CMS beam and radiation monitoring subsystem BCM1F (Fast Beam Condition Monitor) consists of 8 individual diamond sensors situated around the beam pipe within the pixel detector volume, for the purpose of fast bunch-by-bunch monitoring…
For the PIP-II program, transverse emittance in the Fermilab Booster must remain well controlled at higher bunch intensities. 4-plate beam position monitors (BPMs) have a small but measurable quadrupole moment, making it possible to infer…
MiMiC is a framework for performing multiscale simulations in which loosely coupled external programs describe individual subsystems at different resolutions and levels of theory. To make it highly efficient and flexible, we adopt an…
An interlock system has been designed for the Fermilab Cryo-module Test Stand (CMTS), a test bed for the cryomodules to be used in the upcoming Linac Coherent Light Source 2 (LCLS-II) project at SLAC. The interlock system features 8…
A new variant of bit interleaved coded modulation (BICM) is proposed. In the new scheme, called Parallel BICM, L identical binary codes are used in parallel using a mapper, a newly proposed finite-length interleaver and a binary dither…
The Fermilab Linac delivers 400MeV, 25mA H$^-$; beam. The longitudinal bunch parameters are reconstructed using a Bunch Shape Monitor (BSM) installed in the middle of the Linac. For that, the bunch length is measured as a function of the…
The commissioning of two cryomodule components is underway at Fermilab's Superconducting Radio Frequency (SRF) Accelerator Test Facility. The research at this facility supports the next generation high intensity linear accelerators such as…
The PIP-II linac is an international collaboration project with in kind contributions of key subsystems from multiple countries including India (DAE). In the research and development phase of the project, the LLRF and resonance control…
The CMS Beam Conditions and Radiation Monitoring System, BRM, will support beam tuning, protect the CMS detector from adverse beam conditions, and measure the accumulated dose close to or inside all sub-detectors. It is composed of…
We have reported previously on the conditioning of the high-gradient accelerating cavities in the Fermilab Linac. Automated measurements of the sparking rate have been recorded since 1994 and are reported here. The sparking rate has…
The Cosmic Microwave Background (CMB) primordial B-modes signal is predicted to be much lower than the polarized Galactic emission (foregrounds) in any region of the sky pointing to the need for sophisticated component separation methods.…