Related papers: Detection of X-ray Emission from the Warm-Hot Inte…
We present a new analysis of very deep Chandra observations of the galaxy cluster Abell 1795. Utilizing nearly 750 ks of net ACIS imaging, we are able to resolve the thermodynamic structure of the Intracluster Medium (ICM) on length scales…
A Chandra ACIS-S imaging observation of the nearby galaxy M81 (NGC 3031) reveals 9 luminous soft X-ray sources. The local environments, X-ray spectral properties, and X-ray light curves of the sources are presented and discussed in the…
Large-scale fluctuations of the X-ray background are investigated using the ROSAT All-Sky Survey. The autocorrelation function of the extragalactic background at 1 keV is determined at separations 0.1 - 40 deg. We detect a significant…
We report on the imaging analysis of 200 ks sub-arcsecond resolution Chandra ACIS-S observations of the nearby Seyfert 1 galaxy NGC 4151. Bright, structured soft X-ray emission is observed to extend from 30 pc to 1.3 kpc in the south-west…
We present the first results from 60ks of observations of Arp 220 using the ACIS-S instrument on Chandra. We report the detection of several sources near the galaxy's nucleus, including a point source with a hard spectrum that is coincident…
We report on the Achromatic Interfero Coronagraph, a focal imaging device which aims at rejecting the energy contribution of a point-like source set on-axis, so as to make detectable its angularly-close environment (applicable to stellar…
We report the results of the Chandra ACIS sub-arcsecond resolution X-ray observation of the archetypal merger radio galaxy NGC 1316 (Fornax A). We confirm the presence of fine sub-structures in the hot Interstellar Medium (ISM). Some of…
The Chandra COSMOS Survey (C-COSMOS) is a large, 1.8 Ms, Chandra program that has imaged the central 0.9 deg^2 of the COSMOS field down to limiting depths of 1.9 10^-16 erg cm^-2 s-1 in the 0.5-2 keV band, 7.3 10^-16 erg cm^-2 s^-1 in the…
Galaxy evolution is regulated by the interplay between galactic disks and their surrounding medium. We study this interplay by examining how the galactic coronal emission efficiency of stellar feedback depends on the (surface and specific)…
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation…
The Infrared Space Observatory was used to search for a tracer of the warm and dense neutral interstellar medium, the [O I] 63.18 micron line, in four ultraluminous IRAS sources lying at redshifts between 0.6 and 1.4. While these sources…
We report the detection of well resolved, extended X-ray emission from the young planetary nebula BD+303639 using the Advanced CCD Imaging Spectrometer (ACIS) aboard the Chandra X-ray Observatory. The X-ray emission from BD+303639 appears…
Three observational constraints can be placed on a warm-hot intergalactic medium (WHIM) using \rosat PSPC pointed and survey data, the emission strength, the energy spectrum, and the fluctuation spectrum. The upper limit to the emission…
Using the Chandra ACIS-I instruments, we have carried out the deepest X-ray observation on a typical Galactic plane region at l 28.5 deg, where no discrete X-ray sources have been known previously. We have detected, as well as strong…
In high-resolution X-ray observations of the hot plasma in clusters of galaxies significant structures caused by AGN feedback, mergers, and turbulence can be detected. Many clusters have been observed by Chandra in great depth and at high…
The Chandra AO1 HETGS observation of the micro-quasar GRS 1915+105 in the low hard state reveals (1) neutral K absorption edges from Fe, Si, Mg, and S in cold gas, and (2) highly ionized (Fe XXV and Fe XXVI) absorption attributed to a hot…
Ultralight axions with axion-photon couplings $g_{a\gamma\gamma} \sim {\rm few} \times 10^{-11}$ GeV$^{-1}$ may resolve a number of astrophysical anomalies, such as unexpected ~TeV transparency, anomalous stellar cooling, and X-ray excesses…
The exquisite angular resolution available with Chandra should allow precision measurements of faint diffuse emission surrounding bright sources, such as the X-ray scattering halos created by interstellar dust. However, the ACIS CCDs suffer…
We present Chandra observations that provide the most direct evidence to date for the pervasive, moderate density, shock-heated intergalactic medium predicted by leading cosmological scenarios. We also comment briefly on future observations…
The ACIS front-illuminated CCDs onboard the Chandra X-ray Observatory were damaged in the extreme environment of the Earth's radiation belts, resulting in enhanced charge transfer inefficiency (CTI). This produces a row dependence in gain,…