Related papers: Gas gun shock experiments with single-pulse x-ray …
Precise diagnostic on the electron beam parameters is a very valuable tool and essential in the operation of synchrotron light sources. One possible option is to employ the emitted synchrotron radiation for non-destructive measurements. A…
We present the experimental production and characterization of a dense cold atomic cloud of \(^{88}\text{Sr}\) atoms, optimized for the future studies of light transport in highly dense regimes. Using narrow-line molasses on the 689 nm…
A novel X-ray diagnostic of laser-fusion plasmas is described, allowing 2D monochromatic images of hot, dense plasmas to be obtained in any X-ray photon energy range, over a large domain, on a single-shot basis. The device (named…
The PCI diagnostic is an internal reference interferometer that creates an image of absolutely calibrated electron density fluctuations integrated along the line of sight of the probing light beam. While conventional PCI diagnostics…
The use of coherent x-ray beams has been greatly developing for the past decades. They are now used by a wide scientific community to study biological materials, phase transitions in crystalline materials, soft matter, magnetism, strained…
Modern Flash X-ray diffraction Imaging (FXI) acquires diffraction signals from single biomolecules at a high repetition rate from X-ray Free Electron Lasers (XFELs), easily obtaining millions of 2D diffraction patterns from a single…
Recent progress in laser wakefield acceleration has led to the emergence of a new generation of electron and X-ray sources that may have enormous benefits for ultrafast science. These novel sources promise to become indispensable tools for…
In high-energy flash radiography, scattered photons will degrade the acquiring image, which limits the resolving power of the interface and density of the dense object. The application of large anti-scatter grid is capable of remarkably…
Ptychography has become prominent at synchrotron facilities worldwide for characterizing biological and material specimens' topological structures and properties at the nanometer or atomic scale, due to its lens - less, highly quantitative…
We introduce a theoretical framework for single-shot phase contrast imaging (PCI) measurements of spinor Bose-Einstein condensates. Our model allows for the simple calculation of the quantum backaction resulting from the measurement, and…
X-ray Fluorescence Ghost Imaging (XRF-GI) was recently demonstrated for x-ray lab sources. It has the potential to reduce acquisition time and deposited dose by choosing their trade-off with spatial resolution, while alleviating the…
Modern imaging techniques at the molecular scale rely on utilizing novel coherent light sources like X-ray free electron lasers for the ultimate goal of visualizing such objects as individual biomolecules rather than crystals. Here, unlike…
A dc electron gun, generating picosecond pulses with up to $8\times10^{6}$ electrons per pulse, was developed. Its applicability for future time-resolved-diffraction experiments on state- and conformer-selected laser-aligned or oriented…
A pump-probe dark-field X-ray microscopy (DFXM) experiment was carried out at the Advanced Photon Source (APS) with nanosecond drive laser pulses and hybrid mode X-ray probe pulses. We observe a thermal decay due to laser-induced heat…
Phase Contrast Imaging (PCI), Dark-Field (DF) and Directional Dark-Field (DDF) imaging are recent X-ray imaging modalities that have demonstrated their interest by providing access to information and contrasts different from those provided…
Pump-probe time-resolved x-ray diffraction of allowed and nearly forbidden reflections in InSb is used to follow the propagation of a coherent acoustic pulse generated by ultrafast laser-excitation. The surface and bulk components of the…
We propose a novel data-driven approach for analyzing synchrotron Laue X-ray microdiffraction scans based on machine learning algorithms. The basic architecture and major components of the method are formulated mathematically. We…
We demonstrate that in situ coherent diffractive imaging (CDI), which harnesses the coherent interference between a strong and a weak beam illuminating a static and dynamic structure, can be a very dose-efficient imaging method. At low…
In conventional x-ray ptychography, diffraction data is collected by scanning a sample through a monochromatic, and spatially coherent, x-ray beam. A high-resolution image is then retrieved using an iterative algorithm. Combined with a scan…
The evolution from 3rd to 4th generation synchrotron radiation (SR) sources significantly enhanced their coherence, making coherent scattering techniques such as coherent X-ray diffraction imaging (CXDI) and X-ray photon correlation…