Related papers: New Limits on Interactions between Weakly Interact…
Limits on the cross section for weakly interacting massive particles (WIMPs) scattering off nucleons in the NaI(Tl) detectors at the Yangyang Underground Laboratory are obtained with a 2967.4 kg*day data exposure. Nuclei recoiling are…
We present constraints on weakly interacting massive particles (WIMP)-nucleus scattering from the 2013 data of the Large Underground Xenon dark matter experiment, including $1.4\times10^{4}\;\mathrm{kg\; day}$ of search exposure. This new…
The Korea Invisible Mass Search(KIMS) experiment presents new limits on WIMP-nucleon cross section using the data from an exposure of 3409 kgd taken with low background CsI(Tl) crystals at Yangyang underground laboratory. The most stringent…
We present a search for low-mass ($\leq 20 GeV/c^{2}$) weakly interacting massive particles(WIMPs), strong candidates of dark matter particles,using the low-background CsI(Tl) detector array of the Korea Invisible Mass Search (KIMS)…
New constraints are presented on the spin-dependent WIMP-nucleon interaction from the PandaX-II experiment, using a data set corresponding to a total exposure of 3.3$\times10^4$ kg-days. Assuming a standard axial-vector spin-dependent WIMP…
We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region blinded.…
A search for Weakly Interacting Massive Particles (WIMPs) was conducted with the single-phase liquid-xenon detector XMASS through inelastic scattering in which $^{129}$Xe nuclei were excited, using an exposure ($\rm 327\; kg \times 800.0 \;…
We present limits on spin-independent inelastic weakly interacting massive particles (WIMP)-nucleus scattering using the 737.1 kg$\cdot$day dataset from the CDEX-1B experiment. Expected nuclear recoil spectra for various inelastic WIMP…
The Cryogenic Dark Matter Search (CDMS-II) employs low-temperature Ge and Si detectors to seek Weakly Interacting Massive Particles (WIMPs) via their elastic scattering interactions with nuclei. Simultaneous measurements of both ionization…
We present constraints on the existence of weakly interacting massive particles (WIMPs) from an 11 kg-day target exposure of the DAMIC experiment at the SNOLAB underground laboratory. The observed energy spectrum and spatial distribution of…
We report the first experimental results on spin-dependent elastic weakly interacting massive particle (WIMP) nucleon scattering from the XENON1T dark matter search experiment. The analysis uses the full ton year exposure of XENON1T to…
We report the results of a search for inelastic scattering of weakly interacting massive particles (WIMPs) off $^{127}$I nuclei using NaI(Tl) crystals with a data exposure of 97.7 kg$\cdot$years from the COSINE-100 experiment. The signature…
The Cryogenic Dark Matter Search (CDMS) employs low-temperature Ge and Si detectors to search for Weakly Interacting Massive Particles (WIMPs) via their elastic-scattering interactions with nuclei while discriminating against interactions…
We present the first constraints on the spin-dependent, inelastic scattering cross section of Weakly Interacting Massive Particles (WIMPs) on nucleons from XENON100 data with an exposure of 7.64$\times$10$^3$\,kg\,day. XENON100 is a…
Weakly Interacting Massive Particles (WIMPs) are one of the leading candidates for Dark Matter. For understanding the properties of WIMPs and identifying them among new particles produced at colliders (hopefully in the near future),…
We report the results of a search for the inelastic scattering of weakly interacting massive particles (WIMPs) in the XENON1T dark matter experiment. Scattering off $^{129}$Xe is the most sensitive probe of inelastic WIMP interactions, with…
We report on a search for weakly interacting massive particle (WIMP) dark matter (DM) via elastic DM-xenon-nucleus interactions in the XENONnT experiment. We combine datasets from the first and second science campaigns resulting in a total…
We report results of a search for Weakly Interacting Massive Particles (WIMPS) with the silicon detectors of the CDMS II experiment. This blind analysis of 140.2 kg-days of data taken between July 2007 and September 2008 revealed three…
KIMS-NaI is a direct detection experiment searching for Weakly Interacting Massive Particles (WIMP) via their scattering off of nuclei in a NaI(Tl) crystal. The KIMS-NaI collaboration has carried out tests of six crystals in the Yangyang…
The SIMPLE project uses superheated C2ClF5 liquid detectors to search for particle dark matter candidates. We report the results of the first stage exposure (14.1 kgd) of its latest two-stage, Phase II run, with 15 superheated droplet…