Related papers: Using of the natural radioactive elements for dete…
The experimental - calculated method is proposed to determine the full energy peak efficiency (FEPE) of detectors {\epsilon}(E) in case a measurement of the large-volume samples. Water is used as standard absorber in which the linear…
The alpha-radiometric determination of uranium after its pre-concentration from natural water samples using the cation-exchange resin Chelex-100, its selective extraction by tributylphosphate and electrodeposition on stainless steel discs…
We present an improved approach for detection of trace amounts of $^{238}$U by means of neutron activation analysis (NAA). The analysis enhancement is obtained by utilizing $\gamma$-$\gamma$ coincidence counting. An empirical method for…
Rare event searches require extreme radiopurity in all detector components. This includes the active medium, which in the case of gaseous detectors, is the operating gas. The gases used typically include noble gas mixtures with molecular…
Sapphire has mechanical and electrical properties that are advantageous for the construction of internal components of radiation detectors such as time projection chambers and bolometers. However, it has proved difficult to assess its $\rm…
Available estimates for the energy resolution of DUNE vary by as much as a factor of four. To address this controversy, and to connect the resolution to the underlying physical processes, we build an independent simulation pipeline for…
A distributed uranium source with the accurately certified activity of 238U has been used to verify the effective mass of the HPGe detector intended for the {\nu}GeN neutrino experiment. The source, dissolved in nitric acid, provides…
Using high-resolution gamma-ray spectroscopy, the terrestrial gamma radiation in all the predominant types of geological rock formations appearing in Cyprus was measured. Soil samples were collected from each rock type, sealed in 1-litre…
Oxygen, nitrogen and methane purification efficiencies for a common zirconium getter are measured in 1050 Torr of xenon gas. Starting with impurity concentrations near 10^{-6} g/g, the outlet impurity level is found to be less than…
Four methods for determining the composition of low-level uranium- and thorium-chain surface contamination are presented. One method is the observation of Cherenkov light production in water. In two additional methods a position-sensitive…
High-purity germanium crystals approximately 12 cm in diameter were grown in a hydrogen atmosphere using the Czochralski method. The dislocation density of the crystals was determined to be in the range of 2000 - 4200 cm-2, which meets a…
A first study of neutron tagging is conducted in Super--Kamiokande, a 50,000-ton water Cherenkov detector. The tagging efficiencies of thermal neutrons are evaluated in a 0.2 % GdCl$_{3}$-water solution and pure water. They are determined…
The amount of energy released by a nuclear recoil ionizing the atoms of the active volume of detection appears "quenched" compared to an electron of the same kinetic energy. This different behavior in ionization between electrons and nuclei…
As gaseous detectors are operated at high rates of primary ionisation, ions created in the detector have a considerable impact on the performance of the detector. The upgraded ALICE Time Projection Chamber (TPC) will operate during LHC…
Although reliable models may predict the detection efficiency of semiconductor detectors, measurements are needed to check the parameters supplied by the manufacturers namely the thicknesses of dead layer, beryllium window and crystal…
A comprehensive study was conducted to determine thorium, uranium and potassium elemental concentrations in surface soils throughout the accessible area of Cyprus using high-resolution gamma-ray spectrometry. A total of 115 soil samples was…
A standard high purity germanium (HPGe) detector was used to determine the previously unknown neutron activity of a weak americium-beryllium (AmBe) neutron source. Gamma rays were created through 27Al(n,n'), 27Al(n,gamma) and 1H(n,gamma)…
Study of the uniformity of gain, energy resolution and count rate over active area of a triple GEM detector has been performed using a strong Fe55 X-ray source with premixed gas of Argon and CO2 in 70/30 ratio and conventional NIM…
In this work a set of simulations that aim at the optimization of gaseous detectors for applications in X-ray fluorescence imaging in the energy range of 3 -- 30keV is presented. By studying the statistical distribution of the radiation…
Rare event searches demand extremely low background levels, necessitating ever-advancing screening techniques to enhance sensitivity. Liquid scintillators are highly attractive as detector media due to their inherent radiopurity and…