Related papers: Reduction of thermal fluctuations in a cryogenic l…
Mirror thermal noise is and will remain one of the main limitations to the sensitivity of gravitational wave detectors based on laser interferometers. We report about projected mirror thermal noise due to losses in the mirror coatings and…
A fundamental limit to the sensitivity of optical interferometers is imposed by Brownian thermal fluctuations of the mirrors' surfaces. This thermal noise can be reduced by using larger beams which "average out" the random fluctuations of…
We propose a simple way to improve the laser gravitational-wave detectors sensitivity by means of reduction of the number of reflective coating layers of the core optics mirrors. This effects in the proportional decrease of the coating…
Crystalline materials are promising candidates as substrates or high-reflective coatings of mirrors to reduce thermal noises in future laser interferometric gravitational wave detectors. However, birefringence of such materials could…
We present the calculation of thermal noise in interferometric gravitational-wave detectors due to the thermal fluctuations of the beam splitter (BS). This work makes use of a recently developed method of the analysis of thermal noise in…
A fundamental limit to the sensitivity of optical interferometry is thermal noise that drives fluctuations in the positions of the surfaces of the interferometer's mirrors, and thereby in the phase of the intracavity field. Schemes for…
Increasing requirements in the sensitivity of interferometric measurements is a common feature of several research fields, from gravitational wave detection to quantum optics. This motivates refined studies of high reflectivity mirrors and…
We report the mirror suspension design for Large-scale Cryogenic Gravitational wave Telescope, KAGRA, during bKAGRA Phase 1. Mirror thermal noise is one of the fundamental noises for room-temperature gravitational-wave detectors such as…
We show that fast technical fluctuations of microwave signals can be strongly suppressed by cryogenic resonators. The experiments were carried out with sapphire resonators cooled to approximately 6 K at frequencies around 11 GHz. Each…
We report the reduction of the thermal lensing in cryogenic sapphire mirrors, which is planed to be used in the Large scale Cryogenic Gravitational wave Telescope (LCGT) project. We measured three key parameters of sapphire substrate for…
The displacement fluctuations of mirrors in optomechanical devices, induced via thermal expansion by temperature fluctuations due either to thermodynamic fluctuations or to fluctuations in the photon absorption, can be made smaller than…
Thermodynamical fluctuations of temperature in mirrors may produce surface fluctuations not only through thermal expansion in mirror body but also through thermal expansion in mirror coating. We analyze the last "surface" effect which can…
A major barrier to improving the quantum-limited sensitivity of gravitational-wave observatories is the thermal distortions of the test masses which arise at megawatt laser power. Recent advances in a new form of higher-order wavefront…
A vacuum compatible cryogenic accelerometer is presented which will reach $<0.5$ p$g$ Hz$^{-1/2}$ sensitivity from 1 mHz to 10 Hz with a maximum sensitivity of 10 f$g$ Hz$^{-1/2}$ around 10 Hz. This figure can be translated to a…
We have measured the mechanical loss of a dielectric multilayer reflective coating (ion-beam sputtered SiO$_2$ and Ta$_2$O$_5$) in cooled mirrors. The loss was nearly independent of the temperature (4 K $\sim$ 300 K), frequency, optical…
The frequency stability of a laser locked to an optical reference cavity is fundamentally limited by thermal noise in the cavity length. These fluctuations are linked to material dissipation, which depends both on the temperature of the…
Thermodynamical fluctuations of temperature in mirrors of gravitational wave antennae are transformed through thermal expansion coefficient into additional noise. This source of noise, which may also be interpreted as fluctuations due to…
Thermal noise of a mirror is one of the limiting noise sources in the high precision measurement such as gravitational-wave detection, and the modeling of thermal noise has been developed and refined over a decade. In this paper, we present…
The frequency stability of lasers is limited by thermal noise in state-of-the-art frequency references. Further improvement requires operation at cryogenic temperature. In this context, we investigate a fiber-based ring resonator. Our…
We report the first high-precision interferometer using large sapphire mirrors, and we present the first direct, broadband measurements of the fundamental thermal noise in these mirrors. Our results agree well with the thermoelastic-damping…