Related papers: Sensitivity of an image plate system in the XUV (6…
The response of the BAS-TR image plate (IP) was absolutely calibrated using CR-39 track detector for high linear energy transfer (LET) Au ions up to $\sim$1.6 GeV (8.2 MeV/nucleon), accelerated by high-power lasers. The calibration was…
A high resolution vacuum ultraviolet (HRVUV) beamline based on a 6.65 meter off-plane Eagle spectrometer is in operation at the Indus-1 synchrotron radiation source, RRCAT, Indore, India. To facilitate position sensitive detection and fast…
Pulses of extreme ultraviolet (XUV) light, with wavelengths between 10 and 100$\,$nm, can be used to image and excite ultra-fast phenomena such as the motion of atomic electrons. Here we show that the illumination of plasma with…
We report on a compact and spectrally intense extreme-ultraviolet (XUV) source, which is based on high-harmonic generation (HHG) driven by 395 nm pulses. In order to minimize the XUV virtual source size and to maximize the XUV flux, HHG is…
We measured the response of BAS-TR imaging plate (IP) to energetic aluminum ions in the 0 to 222 MeV energy range, and compared it with predictions from a Monte Carlo simulation code using two different IP models. Energetic aluminum ions…
Transition Edge Sensor (TES) spectrometers for hard X-ray beamline science will enable improved X-ray emission and absorption spectroscopy in the information-rich 2 to 20 keV energy range. We are building a TES-based instrument for the…
A VUV beamline at SSRF for ARPES measurements are designed. To increase the resolution and bulk sensitivity, the photon energy as low as 7 eV is desired. Because the reflectivity for p-polarized photons strongly decreases when the photon…
A high-energy photon polarimeter for astrophysics studies in the energy range from 10 MeV to 800 MeV is considered. The proposed concept uses a stack of silicon micro-strip detectors where they play the roles of both a converter and a…
All observations by the aperture photometer (PHT-P) and the far-infrared (FIR) camera section (PHT-C) of ISOPHOT included reference measurements against stable internal fine calibration sources (FCS) to correct for temporal drifts in…
Relative cross sections for the valence shell photoionisation (PI) of $\rm ^2S$ ground level and $\rm ^2D$ metastable Ca$^{+}$ ions were measured with high energy resolution by using the ion-photon merged-beams technique at the Advanced…
The operation of a frequency comb at extreme ultraviolet (XUV) wavelengths based on pair-wise amplification and nonlinear upconversion to the 15th harmonic of pulses from a frequency comb laser in the near-infrared range is reported.…
A high spectral resolution observation of the diffuse X-ray background in the 60 - 1000 eV energy range has been made using an array of thirty-six 1 mm^2 micro-calorimeters flown on a sounding rocket. Detector energy resolution ranged from…
We report on a precision measurement of the $(5\mathrm{p})^{5}6\mathrm{p} \, [1/2]_{0}\leftarrow (5\mathrm{p})^{6} \, ^{1}\mathrm{S}_{0}$ transition wavenumber of Xe by Doppler-free two-photon spectroscopy using…
To understand the scientific imaging capability, one must characterize the intra-pixel sensitivity variation (IPSV) of the CMOS image sensor. Extracting an IPSV map contributes to an improved detector calibration that allows to eliminate…
We demonstrate submicrometer focusing of isolated attosecond pulses (IAPs) in the extreme ultraviolet (XUV) region using a custom ellipsoidal mirror. The obtained focal spot sizes were verified using knife-edge measurements with a sharp…
The intensity of the \oiv~2s$^{2}$ 2p $^{2}$P-2s2p$^{2}$ $^{4}$P and \siv~3 s$^{2}$ 3p $^{2}$P- 3s 3p$^{2}$ $^{4}$ P intercombination lines around 1400~\AA~observed with the \textit{Interface Region Imaging Spectrograph} (IRIS) provide a…
The Athena X-Ray Integral Field Unit (X-IFU) will provide spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) over the 0.2 to 12 keV energy band. It will comprise an array of 3840 superconducting Transition Edge…
We present the results of observations of the PSR B1509$-$58/MSH 15$-$52 system in X-rays ($2-250$ keV) by the Rossi X-ray Timing Explorer. The spectra of the peak of the pulsed component (radio phase $0.17-0.53$) is fit by a power law of…
Four Fe IX transitions in the wavelength range 188--198 A are identified for the first time in spectra from the EUV Imaging Spectrometer on board the Hinode satellite. In particular the emission line at 197.86 A is unblended and close to…
Some applications in scientific imaging, like space-based high-precision photometry, benefit from a detailed characterization of the sensitivity variation within a pixel. A detailed map of the intra-pixel sensitivity (IPS) allows to…