English
Related papers

Related papers: Weak value amplification in a shot-noise limited i…

200 papers

Optical Vector Analysers (OVA) are critical for emerging technologies such as integrated photonics and optical positioning. Achieving a sensitivity near the Standard Quantum Limit (SQL) while acquiring a wide spectrum allows an accurate…

In this paper, we explore the possibilities of realizing weak value amplification (WVA) using purely atomic degrees of freedom. Our scheme identifies the internal electronic states and external motional states of a single trapped…

Quantum Physics · Physics 2019-12-18 Chun-wang Wu , Jie Zhang , Yi Xie , Bao-quan Ou , Ting Chen , Wei Wu , Ping-xing Chen

Achieving higher sensitivity is an earnest purpose for precision metrology. As a response to this goal, the weak value amplification approach has been developed for measuring ultra-small physical effects, realizing sensitivity that had…

Quantum Physics · Physics 2019-07-24 Jingzheng Huang , Yanjia Li , Chen Fang , Hongjing Li , Guihua Zeng

Standard weak measurement with an assistant pointer and single weak interaction constrains measurement precision and quantity of interaction parameters, and a compelling characterization of quantum effect featuring weak-value amplification…

Quantum Physics · Physics 2024-05-14 Yanqiang Guo , Jianchao Zhang , Jiahui Hou , Xiaomin Guo , Liantuan Xiao

The optical interferometry has been widely used in various high precision applications. Usually, the minimum precision of an interferometry is limited by various technique noises in practice. To suppress such kind of noises, we propose a…

Optics · Physics 2018-06-20 Chen Fang , Jing-Zheng Huang , Guihua Zeng

The weak-value (WV) measurement proposed by Aharonov, Albert and Vaidman (AAV) has attracted a great deal of interest in connection with quantum metrology. In this work, we extend the analysis beyond the AAV limit and obtain a few main…

Quantum Physics · Physics 2023-09-26 Jianhua Ren , Lupei Qin , Wei Feng , Xin-Qi Li

Weak amplification is a signal enhancement technique which is used to measure tiny changes that otherwise cannot be determined because of technical limitations. It is based on the existence of a special type of interaction which couples a…

Quantum Physics · Physics 2015-06-04 Juan P. Torres , Graciana Puentes , Nathaniel Hermosa , Luis Jose Salazar-Serrano

We introduce a hybrid methodology that synergistically combines weak value amplification (WVA) and deep learning to suppress the limiting effects of residual timing jitter in pump-probe interferometry, achieved through simulations of…

Optics · Physics 2025-11-18 Jing-Hui Huang , Xiang-Yun Hu

The technical merits of weak value amplification techniques are analyzed. We consider models of several different types of technical noise in an optical context and show that weak value amplification techniques (which only use a small…

Optics · Physics 2016-03-01 Andrew N. Jordan , Julián Martínez-Rincón , John C. Howell

Weak measurements in combination with post-selection can give rise to a striking amplification effect (related to a large "weak value"). We show that this effect can be understood by viewing the initial state of the pointer as the ground…

Quantum Physics · Physics 2015-05-20 Christoph Simon , Eugene S. Polzik

A protocol employing weak values (WVs) to obtain ultra sensitive amplification of weak signals in the context of a solid state setup is proposed. We consider an Aharonov-Bohm interferometer where both the orbital and the spin degrees of…

Mesoscale and Nanoscale Physics · Physics 2013-02-18 Oded Zilberberg , Alessandro Romito , Yuval Gefen

We examine the effect of different sources of technical noise on inverse weak value-based precision phase measurements. We find that this type of measurement is similarly robust to technical noise as related experiments in the weak value…

Quantum Physics · Physics 2020-09-07 Kevin Lyons , John C. Howell , Andrew N. Jordan

The weak measurement proposed by Aharonov and his colleagues extracts information of a physical quantity of the system by the post selection as the shifts of the argument of the probe wavefunction. The shift is called the weak value and is…

Quantum Physics · Physics 2012-05-14 Yuki Susa , Yutaka Shikano , Akio Hosoya

We present an integrated design to precisely measure optical frequency using weak value amplification with a multi-mode interferometer. The technique involves introducing a weak perturbation to the system and then post-selecting the data in…

Quantum Physics · Physics 2022-02-02 John Steinmetz , Kevin Lyons , Meiting Song , Jaime Cardenas , Andrew N. Jordan

A modified-weak-value-amplification(MWVA) technique of measuring the mirror's velocity based on the Vernier-effect has been proposed. We have demonstrated with sensitivity-enhanced and the higher signal-to-noise ratio(${\rm SNR}$) by using…

Optics · Physics 2022-05-13 Jing-Hui Huang , Fei-Fan He , Xue-Ying Duan , Guang-Jun Wang , Xiang-Yun Hu

An experimental proposal is presented in which dark port post-selection together with weak measurements are used to enlarge the radiation pressure effect of a single photon on a mechanical oscillator placed in the middle of a Fabry-Perot…

Quantum Physics · Physics 2019-01-09 Sergio Carrasco , Miguel Orszag

The auto-correlative weak-value amplification (AWVA) technique demonstrates distinct advantages over standard weak-value amplification (SWVA) for quantum parameter estimation. To achieve enhanced precision in real-time parameter estimation,…

Quantum Physics · Physics 2025-07-25 Jing-Hui Huang , Guang-Jun Wang , Xiang-Yun Hu

Weak measurement amplification, which is considered as a very promising scheme in precision measurement, has been applied to various small physical quantities estimation. Since many quantities can be converted to phase signal, it is thus…

In the Aharonov-Albert-Vaidman (AAV) weak measurement, it is assumed that the measuring device or the pointer is in a quantum mechanical pure state. In reality, however, it is often not the case. In this paper, we generalize the AAV weak…

Quantum Physics · Physics 2010-02-25 Young-Wook Cho , Hyang-Tag Lim , Young-Sik Ra , Yoon-Ho Kim

We propose a postselected amplification (PSA) scheme for phase shift measurement of optical coherent states when passing through the Mach-Zehnder-interferometer (MZI). Different from the usual weak-value-amplification (WVA) formulation, the…

Quantum Physics · Physics 2025-04-28 J. L. Li , Y. Z. Niu , L. P. Qin , X. Q. Li