English
Related papers

Related papers: Characterization of microbulk detectors in argon- …

200 papers

A new Micromegas manufacturing technique, based on kapton etching technology, has been recently developed, improving the uniformity and stability of this kind of readouts. Excellent energy resolutions have been obtained, reaching 11% FWHM…

We report on a systematic characterization of microbulk Micromegas readouts in high-pressure Ar+1%iC4H10 and Ne+2%iC4H10 mixtures. Experimental data on gain, electron transmission and energy resolution are presented for a wide range of…

Instrumentation and Detectors · Physics 2022-08-03 F. J. Iguaz , T. Dafni , C. Canellas , J. F. Castel , S. Cebrián , J. G. Garza , I. G. Irastorza , G. Luzón , H. Mirallas , E. Ruiz Chóliz

The latest Micromesh Gas Amplification Structures (Micromegas) are achieving outstanding energy resolution for low energy photons, with values as low as 11% FWHM for the 5.9 keV line of $^{55}$Fe in argon/isobutane mixtures at atmospheric…

Instrumentation and Detectors · Physics 2015-05-13 T. Dafni , E. Ferrer-Ribas , I. Giomataris , Ph. Gorodetzky , F. Iguaz , I. G. Irastorza , P. Salin , A. Tomas

The present work involves the comparison of various bulk Micromegas detectors having different design parameters. Six detectors with amplification gaps of $64,~128,~192,~220 ~\mu\mathrm{m}$ and mesh hole pitch of $63,~78 ~\mu\mathrm{m}$…

Instrumentation and Detectors · Physics 2016-05-12 Purba Bhattacharya , Sudeb Bhattacharya , Nayana Majumdar , Supratik Mukhopadhyay , Sandip Sarkar , Paul Colas , David Attie

The bulk Micromegas detector is considered to be a promising candidate for building TPCs for several future experiments including the projected linear collider. The standard bulk with a spacing of 128 micron has already established itself…

Instrumentation and Detectors · Physics 2016-05-11 Purba Bhattacharya , Sudeb Bhattacharya , Nayana Majumdar , Supratik Mukhopadhyay , Sandip Sarkar , Paul Colas , David Attie

For manufacturing Micromegas detectors, the "bulk" method based on photoetching, was successfully developed and widely used in nuclear and particle physics experiments. However, the complexity of the method requires a considerable number of…

Instrumentation and Detectors · Physics 2020-12-14 Jianxin Feng , Zhiyong Zhang , Jianbei Liu , Binbin Qi , Anqi Wang , Ming Shao , Yi Zhou

A muon tracking system consisting of four 9cm x 10cm sized bulk Micromegas detectors with 128um amplification-gap and two 10cm x 10cm triple GEM detectors is foreseen for high-precision tracking of 140GeV muons at the H8 beamline at CERN…

Instrumentation and Detectors · Physics 2015-06-03 Jonathan Bortfeldt , Otmar Biebel , David Heereman , Ralf Hertenberger

Working gas components significantly impact the performance of gaseous detectors. A fast-timing Micromegas detector with two-stage amplification is prone to notable deterioration of uniformity when scaled up. This paper presents a…

Instrumentation and Detectors · Physics 2024-11-08 Yue Meng , Xu Wang , Jianbei Liu , Ming Shao , Zhiyong Zhang , Yi Zhou

The latest generation of Micromegas detectors show a good energy resolution, spatial resolution and low threshold, which make them idoneous in low energy applications. Two micromegas detectors have been built for dark matter experiments:…

Micromegas is one of the detector technologies (along with the small Thin Gap Chambers) that has been chosen for precision tracking and triggering purposes of the ATLAS muon forward detectors in the view of LHC luminosity increase. To…

Instrumentation and Detectors · Physics 2015-06-17 Georgios Iakovidis

Micro-Pattern Gaseous Detectors (MPGDs) such as Micromegas or GEM are used in particle physics experiments for their capabilities in particle tracking at high rates. Their excellent position resolutions are well known but their energy…

Instrumentation and Detectors · Physics 2011-07-19 T. Zerguerras , B. Genolini , V. Lepeltier , J. Peyre , J. Pouthas , P. Rosier

Micromegas is a type of micro-pattern gaseous detector currently under R&D for applications in rare event search experiments. Here we report the performance of a Micromegas structure constructed with a micromesh thermo-bonded to a readout…

Instrumentation and Detectors · Physics 2014-05-13 Yuehuan Wei , Liang Guan , Zhiyong Zhang , Qing Lin , Xiaolian Wang , Kaixuan Ni , Tianchi Zhao

The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC using a high precision Micromegas readout plane. We will describe in detail the recent developments done with bulk Micromegas detectors as well as the…

Basic R & D have been carried out with one small straw tube detector prototype with premixed gas of Ar+CO2 in 70:30 and 90:10 ratio. The gain and the energy resolution are measured with Fe55 X-ray source. Effect of temperature and pressure…

Instrumentation and Detectors · Physics 2017-09-26 S. Roy , N. Nandi , R. P. Adak , S. Biswas , S. Das , S. K. Ghosh , S. K. Prasad , S. Raha

The Spherical Proportional Counter is a novel type of radiation detector, with a low energy threshold (typically below 100 eV) and good energy resolution. This detector is being developed by the network NEWS, which includes several…

Instrumentation and Detectors · Physics 2015-01-09 F. J. Iguaz , A. Rodriguez , J. F. Castel , I. G. Irastorza

Emulsion detectors feature a very high position resolution and consequently represent an ideal device when particle detection is required at the micrometric scale. This is the case of quantum interferometry studies with antimatter, where…

High Energy Physics - Experiment · Physics 2016-08-03 S. Aghion , A. Ariga , T. Ariga , M. Bollani , E. Dei Cas , A. Ereditato , C. Evans , R. Ferragut , M. Giammarchi , C. Pistillo , M. Romé , S. Sala , P. Scampoli

The results of a beam test performed at the KEK PS in June 2005 are presented. Drift properties of an argon-isobutane mixture have been accurately measured and compared with predictions at magnetic fields between 0 and 1 Tesla. The r.m.s.…

Instrumentation and Detectors · Physics 2009-04-17 D. C. Arogancia

The operation of a Micropattern Gaseous Detector (MPGD) comprising a cascade of two non-standard Gas Electron Multipliers (GEM) made from a 100 micrometer kapton foil was evaluated in pure krypton and in krypton-CO2 mixtures. The final…

Instrumentation and Detectors · Physics 2018-01-12 R. C. Roque , H. Natal da Luz , L. F. N. D. Carramate , C. D. R. Azevedo , J. A. Mir , F. D. Amaro

We report on the calibration of an argon/isobutane (97.7 %/2.3 %)-filled GridPix detector with soft X-rays (277 eV to 8 keV) using the variable energy X-ray source of the CAST Detector Lab at CERN. We study the linearity and energy…

Instrumentation and Detectors · Physics 2018-04-18 Christoph Krieger , Jochen Kaminski , Theodoros Vafeiadis , Klaus Desch

In this study we report the results of a systematic study of the gain, rate and the position resolution limits of various micropattern gaseous detectors. It was found that at low rates (<1 Hz/mm^2) each detector has it own gain limit, which…

Instrumentation and Detectors · Physics 2007-05-23 V. Peskov , P. Fonte
‹ Prev 1 2 3 10 Next ›