English
Related papers

Related papers: Time and position sensitive single photon detector…

200 papers

The design and tests of Timing Counter elements for the upgrade of the MEG experiment, MEG II,is presented. The detector is based on several small plates of scintillator with a Silicon PhotoMultipliers dual-side readout. The optimisation of…

Instrumentation and Detectors · Physics 2015-06-18 M. De Gerone , F. Gatti , W. Ootani , Y. Uchiyama , M. Nishimura , S. Shirabe , P. W. Cattaneo , M. Rossella

A characterisation of scintillating fibres with silicon photomultiplier read-out was performed in view of their possible application in fibre tracking detector systems. Such a concept is being considered for the Kaos spectrometer at the…

Instrumentation and Detectors · Physics 2011-06-30 P. Achenbach , A. Sanchez Lorente , S. Sánchez Majos , J. Pochodzalla

The project involved the development of a precision radioactive Source-Positioning System to enable the absolute characterization of a gamma-ray Detector-Development Platform at the Division of Nuclear Physics at Lund University in…

Instrumentation and Detectors · Physics 2017-06-16 Mohamad Akkawi

Distinguishing photon-arrival time and position is crucial for advancing quantum technology. However, capturing spatial and temporal information efficiently remains challenging. Here, we present a novel photon-detection technique to achieve…

Quantum Physics · Physics 2024-07-24 Ozora Iso , Kensuke Miyajima , Ryosuke Shimizu

At high luminosity areas, beam loss monitor with fast response and high radiation resistance is crucial for accelerator operation. In this article, we report the design and test results of a fast response and radiation-resistant…

Instrumentation and Detectors · Physics 2023-03-01 Yuanjing Ji , Zebo Tang , Chen Li , Xin Li , Ming Shao

We report the performance and characterization of a custom-built hybrid detector consisting of BC501A liquid scintillator for fast neutrons and BC702 scintillator for thermal neutrons. The calibration and the resolution of the BC501A liquid…

We report on the construction and upgrade of a Lawrence Berkeley National Laboratory Cosmic Muons Detector. We modify the electronics and mechanics to achieve a highly efficient gamma-ray and cosmic-ray detector. Each detector module uses a…

Instrumentation and Detectors · Physics 2011-07-25 Abdel G. Bachri , Perry C. Grant , Azriel Goldschmidt

Various pulse shape discrimination methods have been used to solve the neutron-gamma discrimination problem. But most of them are limited to off-line calculation due to the computation amount and FPGA performance. In order to realize real…

Instrumentation and Detectors · Physics 2022-01-26 Haoqi Ye , Ge Jin , Lian Chen

We present a scintillator based detector able to measure both spatial and energy information at High repetition rate (HRR) with a relatively simple design. It has been built at the Center of Pulsed Laser (CLPU) in Salamanca and tested in…

Instrumentation and Detectors · Physics 2019-04-03 M. Huault , D. De Luis , J. Alpinaniz , M. De Marco , J. A. Perez-Hernandez , N. Gordillo Garcia , C. Gutierrez , L. Roso , G. Gatti , L. Volpe

Prototype of gamma ray detector based on Micro Pixel Avalanche Photodiodes (MAPD) with high pixel density 15000 pixel/$mm^2$, optically coupled to Lutetium Fine Silicate (LFS) scintillator has been developed. The detection performance…

Instrumentation and Detectors · Physics 2013-02-11 E. Guliyev , F. Ahmadov , G. Ahmadov , A. Sadigov , Z. Sadigov , N. Anfimov , Z. Krumshtein , A. Olshevski , V. Shvetsov , V. Zhezher , R. Madatov

The Muon Scattering Experiment at the Paul Scherrer Institut uses a mixed beam of electrons, muons, and pions, necessitating precise timing to identify the beam particles and reactions they cause. We describe the design and performance of…

The detection of 200-1000 MeV neutrons requires large amounts, $\sim$100 cm, of detector material because of the long nuclear interaction length of these particles. In the example of the NeuLAND neutron time-of-flight detector at FAIR, this…

Detectors based on liquid or gas xenon have been used and are in use for a number of applications, in particular for the detection of gamma rays. Xenon is a well-suited medium for gamma spectroscopy thanks to its high atomic number and,…

Instrumentation and Detectors · Physics 2013-09-10 F. Resnati

Organic scintillators exhibit fast timing, high detection efficiency for fast neutrons and pulse shape discrimination (PSD) capability. PSD is essential in mixed radiation fields, where different types of radiation need to be detected and…

Instrumentation and Detectors · Physics 2023-04-05 Jianxin Zhou , Abdullah Abdulaziz , Yoann Altmann , Angela Di Fulvio

Photon counting CT (PCCT) has been a research focus in the last two decades. Recent studies and advancements have demonstrated that systems using semiconductor-based photon counting detectors (PCDs) have the potential to provide better…

Plastic scintillator detectors are used in high energy physics as well as for diagnostic imaging in medicine, beam monitoring on hadron therapy, muon tomography, dosimetry and many security applications. To combine particle tracking and…

The characteristics of the Solid-state Neutron Detector, under development for neutron-scattering measurements at the European Spallation Source, have been simulated with a Geant4-based computer code. The code models the interations of…

We have developed a prototype time-resolved neutron imaging detector employing a micro-pattern gaseous detector known as the micro-pixel chamber ({\mu}PIC) coupled with a field-programmable-gate-array-based data acquisition system. Our…

We report on the position, timing, and energy resolution of a range of plastic scintillator bars and reflector treatments using dual-ended silicon photomultiplier readout. These measurements are motivated by the upcoming construction of an…

The ability to detect the interaction of light and matter at the single-particle level is becoming increasingly important for many areas of science and technology. The absorption or emission of a photon on a narrow transition of a trapped…

Quantum Physics · Physics 2014-04-08 C. Hempel , B. P. Lanyon , P. Jurcevic , R. Gerritsma , R. Blatt , C. F. Roos