Related papers: Four-dimensional Cone Beam CT Reconstruction and E…
Conventional computed tomography (CT) lacks the ability to capture dynamic, weight-bearing joint motion. Functional evaluation, particularly after surgical intervention, requires four-dimensional (4D) imaging, but current methods are…
Reconstructing 3D cone beam computed tomography (CBCT) images from a limited set of projections is an important inverse problem in many imaging applications from medicine to inertial confinement fusion (ICF). The performance of traditional…
Preclinical micro-CT reconstruction involves large projection sizes and volumes that make iterative methods costly - 5x to 50x slower than analytic alternatives on modern GPUs. Whether this cost is justified depends on the imaging task, yet…
Obtaining accurate and reliable images from low-dose computed tomography (CT) is challenging. Regression convolutional neural network (CNN) models that are learned from training data are increasingly gaining attention in low-dose CT…
Cone-beam computed tomography (CBCT) is widely used in image-guided radiotherapy. Reconstructing CBCTs from limited-angle acquisitions (LA-CBCT) is highly desired for improved imaging efficiency, dose reduction, and better mechanical…
X-ray computed tomography is a commonly used technique for noninvasive imaging at synchrotron facilities. Iterative tomographic reconstruction algorithms are often preferred for recovering high quality 3D volumetric images from 2D X-ray…
Due to its wide field of view, cone-beam computed tomography (CBCT) is plagued by large amounts of scatter, where attenuated photons hit the detector, and corrupt the linear models used for reconstruction. Given that one can generate a good…
We study iterative signal reconstruction in computed tomography (CT), wherein measurements are produced by a linear transformation of the unknown signal followed by an exponential nonlinear map. Approaches based on pre-processing the data…
Abstract Purpose: High-quality 4D MRI requires an impractically long scanning time for dense k-space signal acquisition covering all respiratory phases. Accelerated sparse sampling followed by reconstruction enhancement is desired but often…
This study proposes a novel imaging and reconstruction framework for dual-energy cone-beam CT (DECBCT) using only two orthogonal X-ray projections at different energy levels (2V-DECBCT). The goal is to enable fast and low-dose DE volumetric…
Cone-Beam Computed Tomography (CBCT) is an indispensable technique in medical imaging, yet the associated radiation exposure raises concerns in clinical practice. To mitigate these risks, sparse-view reconstruction has emerged as an…
Cone Beam Computed Tomography (CBCT) is widely used in dentistry for diagnostics and treatment planning. CBCT Imaging has a long acquisition time and consequently, the patient is likely to move. This motion causes significant artifacts in…
Poor tissue visualization and quantitative accuracy in CBCT is a major barrier in expanding the role of CBCT imaging from target localization to quantitative treatment monitoring and plan adaptations in radiation therapy sessions. To…
Purpose: To introduce a novel deep learning based approach for fast and high-quality dynamic multi-coil MR reconstruction by learning a complementary time-frequency domain network that exploits spatio-temporal correlations simultaneously…
It is a long-standing challenge to reconstruct Cone Beam Computed Tomography (CBCT) of the lung under respiratory motion. This work takes a step further to address a challenging setting in reconstructing a multi-phase}4D lung image from…
X-ray computed tomography (CT) reveals the materials' internal structures non-destructively from a tilt series of projected images. Filtered back projection (FBP) is a widely-adopted reconstruction algorithm in CT owing to its small…
Cone Beam Computed Tomography (CBCT) finds diverse applications in medicine. Ensuring high image quality in CBCT scans is essential for accurate diagnosis and treatment delivery. Yet, the susceptibility of CBCT images to noise and artifacts…
Motion during acquisition of a set of projections can lead to significant motion artifacts in computed tomography reconstructions despite fast acquisition of individual views. In cases such as cardiac imaging, motion may be unavoidable and…
Three-dimensional (3D) reconstruction of head Computed Tomography (CT) images elucidates the intricate spatial relationships of tissue structures, thereby assisting in accurate diagnosis. Nonetheless, securing an optimal head CT scan…
For medical cone-beam computed tomography (CBCT) imaging, the native receptor array of the flat-panel detector (FPD) is usually binned into a reduced matrix size. By doing so, the signal readout speed can be increased by over 4-9 times at…