Related papers: SiPMs coated with TPB : coating protocol and chara…
In the Energy Frontier we suggest developing high rate (100 MHz) finely segmented forward calorimetry preradiators with time resolution <50 ps which will survive the first 1-2 Lint of incident high radiation doses, protecting forward…
The Silicon Electron Multiplier (SiEM) is a novel sensor concept for minimum ionizing particle (MIP) detection which uses internal gain and fine pitch to achieve excellent temporal and spatial resolution. In contrast to sensors where the…
Silicon photomultipliers (SiPMs) are being considered as potential replacements for conventional photomultiplier tubes (PMTs). However, a significant disadvantage of SiPMs is crosstalk (CT), wherein photons propagate through other pixels,…
The recent improvements in the performance of the silicon photomultipliers (SiPMs) made them attractive options as photo sensors of imaging atmospheric Cherenkov telescopes (IACTs). In fact, they are already adopted in some IACTs such as…
High-granularity homogeneous electromagnetic calorimeters based on scintillating crystals and silicon photomultipliers (SiPMs) are a promising option for future $e^{+}e^{-}$ Higgs factories, where both excellent energy resolution and a very…
Silicon strip sensors have long been a reliable technology for particle detection. Here, we push the limits of silicon tracking detectors by targeting an unprecedentedly low material budget of 2%-7% $X_0$ in an 8-layer 4 m$^2$ detector…
Silicon Photo-Multipliers (SiPMs) are detectors sensitive to single photons that are used to detect scintillation and Cherenkov light in a variety of physics and medical-imaging applications. SiPMs measure single photons by amplifying the…
The NEXT experiment aims to observe the neutrinoless double beta decay of $^{136}$Xe in a high pressure gas TPC using electroluminescence (EL) to amplify the signal from ionization. Understanding the response of the detector is imperative…
In this paper the efficiency of direct charged particle detection with different Silicon PhotoMultiplier (SiPM) sensors has been measured to be close to 100%. Time resolution of about 20 ps has also been confirmed for sensors with an active…
The temperature of a nonneutral plasma confined in a Penning-Malmberg trap can be determined by slowly lowering one side of the trap's electrostatic axial confinement barrier; the temperature is inferred from the rate at which particles…
Modern neutrino physics detectors often employ thousands, and sometimes even hundreds of thousands, of Silicon Photomultipliers (SiPMs). The TAO experiment is a notable example that utilizes a spherical scintillator barrel with a diameter…
A Silicon Photomultiplier (SiPM)-based photodetector is being built to demonstrate its feasibility for an alternative silicon-based camera design for the Large Size Telescope (LST) of the Cherenkov Telescope Array. It has been designed to…
The combination of plastic scintillators with Silicon Photo-Multipliers (SiPMs) is widely used for detecting radiation in high-energy astrophysics, particle physics, neutrino physics, or medical physics. An example of application for this…
This paper describes the characterization of crystal matrices and silicon photomultiplier arrays for a novel Positron Emission Tomography (PET) detector, namely the external plate of the EndoTOFPET-US system. The EndoTOFPET-US collaboration…
In the last ten years silicon photomultipliers (SiPMs) have gained terrain in experiments and applications in which photomultiplier tubes have been the dominant photosensors during decades. Imaging Atmospheric Cherenkov Telescopes (IACTs)…
The last decade has increasingly seen the use of silicon photomultipliers (SiPMs) instead of photomultiplier tubes (PMTs). This is due to various advantages of the former on the latter like its smaller size, lower operating voltage, higher…
The direct response of Silicon PhotoMultipliers being traversed by a MIP charged particle have been studied in a systematic way for the first time. Using beam test data, time resolution and the crosstalk probability have been measured. A…
We present experimental results of characterization of Silicon photomultipliers (SiPM) in a temperature range from 90~mK to 40~K. Two SiPMs, one from ONSEMI and one from Hamamatsu Photonics were tested. Operating voltage ranges, dark count…
The excellent production quality of recent generations of Silicon Photomultipliers (SiPMs) allows for operation without individual calibration of the breakdown voltage. Measurements of the crosstalk probability and the relative gain of 122…
NEXT is a new experiment to search for neutrinoless double beta decay using a 100 kg radio-pure high-pressure gaseous xenon TPC. The detector requires excellent energy resolution, which can be achieved in a Xe TPC with electroluminescence…