English
Related papers

Related papers: Axes determination for segmented true-coaxial HPGe…

200 papers

A high-purity co-axial germanium detector has been calibrated in efficiency to a precision of about 0.15% over a wide energy range. High-precision scans of the detector crystal and gamma-ray source measurements have been compared to…

The next generation of radioactive ion beam facilities, which will give experimental access to many exotic nuclei, are presently being developed. At the same time the next generation of high resolution gamma-ray spectrometers, based on…

Nuclear Experiment · Physics 2010-02-17 P. -A. Söderström , A. Al-Adili , J. Nyberg , F. Recchia , E. Farnea , A. Gadea

High-purity germanium (HPGe) crystals are required to be well-characterized before being fabricated into Ge detectors. The characterization of HPGe crystals is often performed with the Hall Effect system, which measures the carrier…

Instrumentation and Detectors · Physics 2020-12-30 M. -S. Raut , H. Mei , D. -M. Mei , S. Bhattarai , W. -Z. Wei , R. Panda , P. Acharya , G. -J. Wang

Large, high-purity, germanium (HPGe) detectors are needed for neutrinoless double-beta decay and dark matter experiments. Currently, large (> 4 inches in diameter) HPGe crystals can be grown at the University of South Dakota (USD). We…

Instrumentation and Detectors · Physics 2019-03-27 X. -H. Meng , G. -J. Wang , M. -D. Wagner , H. Mei , W. -Z. Wei , J. Liu , G. Yang , D. -M. Mei

Radiation detectors constructed from large volume high purity Ge (HPGe) single crystals are widely used for gamma-ray spectroscopy. The detectors for this application can be simple in that they need only have two electrical contacts for…

Instrumentation and Detectors · Physics 2020-06-11 Mark Amman

Detection systems rely more and more on on-line or off-line comparison of detected signals with basis signals in order to determine the characteristics of the impinging particles. Unfortunately, these comparisons are very sensitive to the…

Nuclear Experiment · Physics 2009-06-16 P. Desesquelles , T. M. H. Ha , A. Korichi , F. Le Blanc , A. Olariu , C. M. Petrache

An algorithm to measure the drift time of charge carriers in p-type point contact (PPC) high-purity germanium (HPGe) detectors from the signals processed with a charge-sensitive preamplifier is introduced. It is demonstrated that the drift…

High-purity germanium (HPGe) crystals underpin some of the most sensitive detectors used in fundamental physics and other high-resolution radiation-sensing applications. Despite their importance, the supply of detector-grade HPGe remains…

Applied Physics · Physics 2026-02-04 Athul Prem , Dongming Mei , Sanjay Bhattarai , Narayan Budhathoki , Sunil Chhetri

We describe here an efficient machine-learning based approach for the optimization of parameters used for extracting the arrival time of waveforms, in particular those generated by the detection of 511 keV annihilation gamma-rays by a 60…

Instrumentation and Detectors · Physics 2020-04-02 R. W. Gladen , V. A. Chirayath , A. J. Fairchild , M. T. Manry , A. R. Koymen , A. H. Weiss

A pulse-shape discrimination method based on artificial neural networks was applied to pulses simulated for different background, signal and signal-like interactions inside a germanium detector. The simulated pulses were used to investigate…

Instrumentation and Detectors · Physics 2015-09-02 A. Caldwell , F. Cossavella , B. Majorovits , D. Palioselitis , O. Volynets

It is assumed that axions exist and are created in the Sun by Primakoff conversion of photons in the Coulomb fields of nuclei. Detection rates are calculated in germanium detectors due to the coherent conversion of axions to photons in the…

High Energy Physics - Phenomenology · Physics 2009-10-30 R. J. Creswick , F. T. Avignone , J. I. Collar , H. A. Farach , A. O. Gattone , S. Nussinov , K. Zioutas

High-purity germanium (HPGe) detectors are widely used for the measurement of the low concentrated radioactivities. For the Super-Kamiokande-Gadolinium project, the concentration of radium in Gd$_2$(SO$_4$)$_3{\cdot}$8H$_2$O is determined…

Instrumentation and Detectors · Physics 2021-10-28 S. Ito , K. Ichimura , Y. Takaku , K. Abe , M. Ikeda , Y. Kishimoto

The peak energy resolution of germanium detectors deteriorates with increasing neutron fluence. This is due to hole capture at neutron-created defects in the crystal which prevents the full energy of the gamma-ray from being recorded by the…

Instrumentation and Detectors · Physics 2017-06-13 C. DeW. Van Siclen , E. H. Seabury , C. J. Wharton , A. J. Caffrey

High purity germanium (HPGe) crystals will be used for the MAJORANA DEMONSTRATOR, where they serve as both the source and the detector for neutrinoless double beta decay. It is crucial for the experiment to understand the performance of the…

A model of the Li-diffused inactive layer in P-type high purity germanium detectors is built to describe the transportation of charge carriers and calculate the charge collection efficiency therein. The model is applied to calculate charge…

Instrumentation and Detectors · Physics 2022-12-29 W. H. Dai , H. Ma , Q. Yue , L. T. Yang , Z. Zeng , J. P. Cheng , J. L. Li

Charge trapping in germanium detectors will inevitably impact their excellent spectral performance. Disordered regions in the germanium crystal structure, either created in the material during processing or induced by radiation exposure,…

Instrumentation and Detectors · Physics 2023-10-03 Steven E. Boggs , Sean N. Pike

The first operational prototype of a high-purity Germanium (HPGe) detector developed within the European LEAPS-INNOV project is presented in this work. This prototype features a monolithic, multi-element sensor optimized for high-resolution…

The characterization of detectors fabricated from home-grown crystals is the most direct way to study crystal properties. We fabricated planar detectors from high-purity germanium (HPGe) crystals grown at the University of South Dakota…

Instrumentation and Detectors · Physics 2018-12-14 W. -Z. Wei , X. -H. Meng , Y. -Y. Yang , J. Liu , G. -J. Wang , H. Mei , G. Gang , D. -M. Mei , C. Zhang

A four-fold segmented n-type point-contact "Broad Energy" high-purity germanium detector, SegBEGe, has been characterised at the Max-Planck-Institut f\"ur Physik in Munich. The main characteristics of the detector are described and first…

Instrumentation and Detectors · Physics 2019-03-27 I. Abt , A. Caldwell , B. Donmez , C. Etrillard , C. Gooch , L. Hauertmann , M. O. Lampert , H. Liao , X. Liu , H. Ma , B. Majorovits , O. Schulz , M. Schuster

A p-type HPGe detector has been segmented by cutting, with a diamond saw, and etching six circumferential grooves through the Li-diffused dead layer. The degree of segmentation was tested with the 88 keV gamma rays from a well-collimated…

‹ Prev 1 2 3 10 Next ›