Related papers: THGEM-based detectors for sampling elements in DHC…
GEM are widely used as amplification stages in gaseous detectors exposed to high rates. The GEM consists of a polyimide foil which is coated by two thin copper layers. Charges collected into the holes or created during the amplification…
The operation of Thick Gas Electron Multipliers (THGEMs) in Time Projection Chambers (TPCs) using various gas mixtures has applications in various nuclear and particle physics experiments. Of particular interest in low-energy nuclear…
We have previously reported on the construction and successful operation of the novel double phase Liquid Argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). This detector concept provides a 3D-tracking and calorimetric…
Optical readout of large Time Projection Chambers (TPCs) with multiple Gas Electron Multipliers (GEMs) amplification stages has shown to provide very interesting performances for high energy particle tracking. Proposed applications for…
We report on discharge probability studies with a single Gas Electron Multiplier (GEM) under irradiation with alpha particles in Ar- and Ne-based gas mixtures. The discharge probability as a function of the GEM absolute gain is measured for…
In-beam evaluation of a fully-equipped medium-size 30$\times$30 cm$^2$ Resistive Plate WELL (RPWELL) detector is presented. It consists here of a single element gas-avalanche multiplier with Semitron ESD225 resistive plate, 1 cm$^2$ readout…
Optical recording of avalanche-induced photons is an interesting tool for studying basic physics processes in gaseous detectors. In this work we demonstrate the potential of optical readout in avalanche-propagation investigations in Thick…
In this work GEM and single-hole Thick GEM structures, composed of different coating materials, are studied. The used foils incorporate conductive layers made of copper, aluminium, molybdenum, stainless steel, tungsten and tantalum. The…
We have recently developed an innovative detector of photons and charged particles: a GEM-like gaseous amplification structure with resistive electrodes instead of commonly used metallic ones. This novel detector combines the best property…
The multi-channel optical readout of a THGEM multiplier coupled to a matrix of 3x3 Geiger-mode APDs (GAPDs) was demonstrated in a two-phase Cryogenic Avalanche Detector (CRAD) in Ar. The GAPDs recorded THGEM-hole avalanches in the Near…
A study has been carried out to evaluate the performance stability of Gas Electron Multiplier (GEM) chamber prototypes in the laboratory using $^{55}$Fe radiation source with Argon and CO$_2$ gas mixture. This research focuses on the…
Gas electron multipliers (GEMs) with wire (WGEMs) or metal electrodes (MGEMs), which don't use any plastic insulators between the electrodes are created. The absence of plastic insulation between the electrodes of WGEMs excludes unwanted…
Gas Electron Multiplier (GEM) detector, one of the advanced members of the Micro Pattern Gas Detector (MPGD) group, is widely used in High Energy Physics (HEP) experiments. The high rate handling capability and spatial resolution make it a…
The simulation of Micro Pattern Gaseous Detectors (MPGDs) signal response is an important and powerful tool for the design and optimization of such detectors. However, several attempts to simulate exactly the effective charge gain have not…
We present design and construction of a large low-mass Triple-GEM detector prototype for forward tracking at a future Electron-Ion Collider. In this environment, multiple scattering of forward and backward tracks must be minimized so that…
A large number of high-energy and heavy-ion experiments successfully used Time Projection Chamber (TPC) as central tracker and particle identification detector. However, the performance requirements on TPC for new high-rate particle…
A novel and relatively simple method of production of electrodes for a multi-channel wire gas multiplier is developed. Two modifications of the multipliers have been tested: with a multiplication of electrons between two wire electrodes,…
For the International Large Detector (ILD) at the planned International Linear Collider (ILC) a Time Projection Chamber (TPC) is foreseen as the main tracking detector. To achieve the required point resolution, Micro Pattern Gaseous…
Radiation-induced proportional-electroluminescence UV signals, emitted from the holes of a Thick Gas Electron Multiplier (THGEM) electrode immersed in liquid xenon, were recorded with a PMT for the first time. Significant photon yields were…
To extend the acceptance of the CMS muon spectrometer to the region 2.4 $<|\eta|<$ 2.8, stacks of triple-GEM chambers, forming the ME0 station, are planned for the CMS Phase 2 Upgrade. These large-area micro-pattern gaseous detectors must…