English
Related papers

Related papers: Performance data from the ZEPLIN-III second scienc…

200 papers

The neutron background at the underground laboratory at Boulby - a site for several dark matter experiments - is discussed. Special emphasis is put on the neutron background produced by cosmic-ray muons. The most recent versions of the muon…

We have directly measured the energy threshold and efficiency for bubble nucleation from iodine recoils in a CF3I bubble chamber in the energy range of interest for a dark matter search. These interactions cannot be probed by standard…

We present results from the direct search for dark matter with the XENON100 detector, installed underground at the Laboratori Nazionali del Gran Sasso of INFN, Italy. XENON100 is a two-phase time projection chamber with a 62 kg liquid xenon…

Low-pressure gas Time Projection Chambers being developed for directional dark matter searches offer a technology with strong particle identification capability combined with the potential to produce a definitive detection of Galactic…

The main physics topics of interest at LEP2, the CERN electron-positron collider with center-of-mass energy in the range (161-192) GeV, are reviewed. Progresses in both the precision tests of the standard model and the field of discovery…

High Energy Physics - Phenomenology · Physics 2009-09-25 Barbara Mele

The Beijing Electron Spectrometer III (BESIII) is a multipurpose detector that collects data provided by the collision in the Beijing Electron Positron Collider II (BEPCII), hosted at the Institute of High Energy Physics of Beijing. Since…

We present a cosmological analysis of the third-order aperture mass statistic using Dark Energy Survey Year 3 (DES Y3) data. We perform a complete tomographic measurement of the three-point correlation function of the Y3 weak lensing shape…

Particle detectors that use liquid xenon (LXe) as detection medium are among the leading technologies in the search for dark matter weakly interacting massive particles (WIMPs). A key enabling element has been the low-energy detection…

We report on the response of liquid xenon to low energy electronic recoils below 15 keV from beta decays of tritium at drift fields of 92 V/cm, 154 V/cm and 366 V/cm using the XENON100 detector. A data-to-simulation fitting method based on…

Instrumentation and Methods for Astrophysics · Physics 2018-05-30 E. Aprile , J. Aalbers , F. Agostini , M. Alfonsi , F. D. Amaro , M. Anthony , F. Arneodo , P. Barrow , L. Baudis , B. Bauermeister , M. L. Benabderrahmane , T. Berger , P. A. Breur , A. Brown , E. Brown , S. Bruenner , G. Bruno , R. Budnik , L. Bütikofer , J. Calvén , J. M. R. Cardoso , M. Cervantes , D. Cichon , D. Coderre , A. P. Colijn , J. Conrad , J. P. Cussonneau , M. P. Decowski , P. de Perio , P. Di Gangi , A. Di Giovanni , S. Diglio , G. Eurin , J. Fei , A. D. Ferella , A. Fieguth , W. Fulgione , A. Gallo Rosso , M. Galloway , F. Gao , M. Garbini , C. Geis , L. W. Goetzke , L. Grandi , Z. Greene , C. Grignon , C. Hasterok , E. Hogenbirk , R. Itay , B. Kaminsky , S. Kazama , G. Kessler , A. Kish , H. Landsman , R. F. Lang , D. Lellouch , L. Levinson , Q. Lin , S. Lindemann , M. Lindner , F. Lombardi , J. A. M. Lopes , A. Manfredini , I. Maris , T. Marrodán Undagoitia , J. Masbou , F. V. Massoli , D. Masson , D. Mayani , M. Messina , K. Micheneau , A. Molinario , K. Morå , M. Murra , J. Naganoma , K. Ni , U. Oberlack , P. Pakarha , B. Pelssers , R. Persiani , F. Piastra , J. Pienaar , V. Pizzella , M. -C. Piro , G. Plante , N. Priel , D. Ramírez García , L. Rauch , S. Reichard , C. Reuter , A. Rizzo , N. Rupp , R. Saldanha , J. M. F. dos Santos , G. Sartorelli , M. Scheibelhut , S. Schindler , J. Schreiner , M. Schumann , L. Scotto Lavina , M. Selvi , P. Shagin , E. Shockley , M. Silva , H. Simgen , M. v. Sivers , A. Stein , D. Thers , A. Tiseni , G. Trinchero , C. Tunnell , M. Vargas , H. Wang , Z. Wang , Y. Wei , C. Weinheimer , J. Wulf , J. Ye , Y. Zhang

The aim of the NEMO 3 experiment is the search for neutrinoless double beta decay and precise measurement of two-neutrino double beta decay of several isotopes. The experiment has been taking data since 2003. Since no evidence for…

High Energy Physics - Experiment · Physics 2019-08-13 Ladislav Vala

Axion Dark Matter eXperiment (ADMX) ultra low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the $2.66$ to $3.1$ $\mu$eV mass range with…

Data are presented from the DRIFT-IId detector housed in the Boulby mine in northeast England. A 0.8 m^3 fiducial volume, containing partial pressures of 30 Torr CS2 and 10 Torr CF4, was exposed for a duration of 47.4 live-time days with…

We report the WIMP dark matter search results using the first physics-run data of the PandaX-II 500 kg liquid xenon dual-phase time-projection chamber, operating at the China JinPing Underground Laboratory. No dark matter candidate is…

Monolithic liquid scintillator detector technology is the workhorse for detecting neutrinos and exploring new physics. The KamLAND-Zen experiment exemplifies this detector technology and has yielded top results in the quest for neutrinoless…

High Energy Physics - Experiment · Physics 2024-10-07 Alexander Migala , Eugene Ku , Zepeng Li , Aobo Li

In the past decade, dual-phase xenon time projection chambers (Xe-TPCs) have emerged as some of the most powerful detectors in the fields of astroparticle physics and rare-event searches. Developed primarily towards the direct detection of…

Instrumentation and Detectors · Physics 2024-02-05 Laura Baudis

The electronics of the LZ experiment, the 7-tonne dark matter detector to be installed at the Sanford Underground Research Facility (SURF), is designed to permit studies of physics where the energies deposited range from 1 keV of…

Instrumentation and Detectors · Physics 2016-03-23 Jun Yin

This article describes the Monte Carlo simulation used to interpret the measurement of the muon-induced neutron flux in the Boulby Underground Laboratory (North Yorkshire, UK), recently performed using a large scintillator veto deployed…

High Energy Physics - Experiment · Physics 2011-05-23 A. Lindote , H. M. Araujo , V. A. Kudryavtsev , M. Robinson

The dependence of the light and charge yield of liquid xenon on the applied electric field and recoil energy is important for dark matter detectors using liquid xenon time projections chambers. Few measurements have been made of this field…

Instrumentation and Methods for Astrophysics · Physics 2017-11-22 L. W. Goetzke , E. Aprile , M. Anthony , G. Plante , M. Weber