Related papers: Extensive simulation studies on the reconstructed …
Coded aperture imaging transcends planar imaging with conventional collimators in efficiency and Field of View (FoV). We present experimental results for the detection of 141keV and 122keV {\gamma}-photons emitted by uniformly extended…
We study the sensitivity of detectors with directional sensitivity to coherent elastic neutrino-nucleus scattering (CE$\nu$NS), and how these detectors complement measurements of the nuclear recoil energy. We consider stopped pion and…
For single source helical Computed Tomography (CT), both Filtered-Back Projection (FBP) and statistical iterative reconstruction have been investigated. However for dual source CT with flying focal spot (DS-FFS CT), statistical iterative…
The result of studies of the energy and spatial resolution of a large volume liquid scintillator detector are presented. The relations are obtained, which allows an estimation of the detector's energy and spatial resolutions without…
Remote sensing images inevitably suffer from various degradation factors during acquisition, including atmospheric interference, sensor limitations, and imaging conditions. These complex and heterogeneous degradations pose severe challenges…
In PET a high percentage of gamma photons being detected undergo Compton scattering in the scintillator. Scintillator blocks are often built from optically isolated crystals. Depending on the angle of incidence and the scintillator geometry…
Due to its wide field of view, cone-beam computed tomography (CBCT) is plagued by large amounts of scatter, where attenuated photons hit the detector, and corrupt the linear models used for reconstruction. Given that one can generate a good…
New type of radiation in crystals is predicted and investigated in computer simulation. It is shown that process of volume reflection of electrons and positrons in bent crystals is accomplished with high-power radiation of photons. Volume…
An optical imager that exploits off-center image rotation to encode both the lateral and depth coordinates of point sources in a single snapshot can perform 3D localization and tracking of space debris. When actively illuminated, unresolved…
This work is the second part of a simulation study investigating the processing of densely packed and moving granular assemblies by positron emission particle tracking (PEPT). Since medical PET scanners commonly used for PEPT are very…
Aims. The purpose of this paper is to describe a new post-processing algorithm dedicated to the reconstruction of the spatial distribution of light received from off-axis sources, in particular from circumstellar disks. Methods. Built on…
This work is concerned with fan- and cone-beam computed tomography with circular source trajectory, where the reconstruction inverse problem requires an accurate knowledge of source, detector and rotational axis relative positions and…
Detectors with continuous scintillator and matrix of photomultipliers attached are widely used in modern particle physics, and various medical tomographs. There are two common ways to calculate the coordinates of the scintillation flash via…
Extracting colorimetric image information from the spectral characteristics of image sensors is a key issue in accurate image acquisition. Technically feasible filter/sensor combinations usually do not replicate colorimetric responses with…
Quantitative phase imaging has become a topic of considerable interest in the microscopy community. We have recently described one such technique based on the use of a partitioned detection aperture, which can be operated in a single shot…
We consider the problem of signal reconstruction for computed tomography (CT) under a nonlinear forward model that accounts for exponential signal attenuation, a polychromatic X-ray source, general measurement noise (e.g., Poisson shot…
A novel method to estimate the pixels simultaneous detection probability and the spatial resolution of pixelized detectors is proposed, which is based on the determination of the statistical correlations between detector neighbor pixels.…
This work introduces an advanced technique optimized for detecting photons generated by charged particles, leveraging Skipper-CCD sensors. By analyzing background sources and detection efficiencies, the technique achieves strong agreement…
We present a detailed study of the spatial resolution of our time-resolved neutron imaging detector utilizing a new neutron position reconstruction method that improves both spatial resolution and event reconstruction efficiency. Our…
In photon-limited imaging, the pixel intensities are affected by photon count noise. Many applications, such as 3-D reconstruction using correlation analysis in X-ray free electron laser (XFEL) single molecule imaging, require an accurate…