Related papers: Luminometer for the future International Linear Co…
Detectors proposed for the International Linear Collider (ILC) incorporate a tungsten sampling calorimeter (`BeamCal') intended to reconstruct showers of electrons, positrons and photons that emerge from the interaction point of the…
More than twenty institutes join the FCAL Collaboration in study of design of the very forward region of a detector for ILC and CLIC. Of particular importance is an accurate luminosity measurement to the level of 10-3, a requirement driven…
Detectors at future $e^+e^-$ colliders need special calorimeters in the very forward region for a fast estimate and precise measurement of the luminosity, to improve the hermeticity and mask the central tracking detectors from backscattered…
A new design of a detector plane of sub-millimetre thickness for an electromagnetic sampling calorimeter is presented. It is intended to be used in the luminometers LumiCal and BeamCal in future linear $e^+e^-$ collider experiments. The…
A highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) is the reference design of the ECAL for International Large Detector (ILD) concept, one of the two detector concepts for the detector(s) at the future International…
The International Linear Collider (ILC) is a future electron/positron collider at the energy frontier. Its physics goals are clearly focused on precision measurements at the electroweak scale and beyond. Beam energy and beam polarisation…
At the International Linear Collider (ILC), measurement of the beam profile at the interaction point (IP) is a key issue to achieve high luminosity. We studied the beam size measurement by combination of Pair Monitor and BeamCal. We…
The International Large Detector (ILD) is a concept for a detector at the International Linear Collider, ILC. The ILC will collide electrons and positrons at energies of initially 500 GeV, upgradeable to 1 TeV. The ILC has an ambitious…
In this paper we describe a method of luminosity measurement at the future linear collider ILC that estimates and corrects for the impact of the dominant sources of systematic uncertainty originating from the beam-induced effects and the…
The first technological SDHCAL prototype having been successfully tested, a new phase of R&D, to validate completely the SDHCAL option for the International Linear Detector (ILD) project of the International Linear Collider (ILC), has…
The FCAL collaboration is preparing large-scale prototypes of special calorimeters to be used in the very forward region at future electron-positron colliders. Two compact calorimeters are foreseen, LumiCal and BeamCal, designed as sandwich…
The FCAL collaboration has performed a design study for luminometers at future electronpositron colliders. Compact sampling calorimeters with precisely positioned silicon sensors and a fast readout will reach the necessary performance even…
The long slab is a new prototype for the SiW-Ecal, a silicon tungsten electromagnetic calorimeter for the ILD detector of the future International Linear Collider. This new prototype has been designed to demonstrate the ability to build a…
High precision physics at future colliders as the International Linear Collider (ILC) require unprecedented high precision in the determination of the energy of final state particles. The needed precision will be achieved thanks to the…
The basic prototype of a tile hadron calorimeter (HCAL) for the International Linear Collider (ILC) has been realised and extensively tested. A major aspect of the proposed concept is the improvement of the jet energy resolution by…
In this study, the sensitivity of future lepton colliders to WIMP dark matter is evaluated assuming WIMP pair production accompanied by a photon from initial state radiation, through which the process can be identified. A full detector…
The International Linear Collider (ILC) will collide polarised electrons and positrons at beam energies of 45.6 GeV to 250 GeV and optionally up to 500 GeV. To fully exploit the physics potential of this machine, not only the luminosity and…
The next major project of particle physics will be the International Linear Collider: a linear accelerator in which electrons and positrons will collide with energies of 500 to around 1000 billion electronvolts. The LPSC-Grenoble is…
To evaluate different technologies for calorimetry at the International Linear Collider, the CALICE collaboration has constructed a highly granular analog hadron calorimeter with small scintillator cells, individually read out by silicon…
The International Linear Collider (ILC) is the next large scale project in accelerator particle physics. Colliding electrons with positrons at energies from 0.3 TeV up to about 1 TeV, the ILC is expected to provide the accuracy needed to…