Related papers: Active Ion Optical Clock
We present a novel method for engineering an optical clock transition that is robust against external field fluctuations and is able to overcome limits resulting from field inhomogeneities. The technique is based on the application of…
We report the direct excitation of the highly forbidden (6s^2) 1S0 - (6s6p) 3P0 optical transition in two odd isotopes of ytterbium. As the excitation laser frequency is scanned, absorption is detected by monitoring the depletion from an…
The uncertainty of the ac Stark shift due to thermal radiation represents a major contribution to the systematic uncertainty budget of state-of-the-art optical atomic clocks. In the case of optical clocks based on trapped ions, the thermal…
An ultrastable optical clock based on neutral atoms trapped in an optical lattice is proposed. Complete control over the light shift is achieved by employing the $5s^2 {}^1S_0 \to 5s5p {}^3P_0$ transition of ${}^{87}{\rm Sr}$ atoms as a…
The $^{27}$Al$^+$ ion optical clock is one of the most attractive optical clocks due to its own advantages, such as low blackbody radiation shift at room temperature and insensitive to the magnetic drift. However, it cannot be laser-cooled…
One path to realizing systems of trapped atomic ions suitable for large-scale quantum computing and simulation is to create a two-dimensional array of ion traps. Interactions between nearest-neighbouring ions could then be turned on and off…
We report a single-ion optical atomic clock with fractional frequency uncertainty of $5.5\times10^{-19}$ and fractional frequency stability of $3.5 \times10^{-16}/\sqrt{\tau/\mathrm{s}}$, based on quantum logic spectroscopy of a single…
Multi-ion optical clocks offer the possibility of overcoming the low signal-to-noise ratio of single-ion clocks, while still providing low systematic uncertainties. We present simultaneous spectroscopy of up to four ${}^{115}$In${}^+$ clock…
We demonstrate state-of-the-art technique of an active clock to provide a continuous superradiant lasing signal using an ensemble of trapped Cs atoms in the optical lattice. A magic wavelength of the proposed |7S1/2; F = 4, MF = 0> -…
Integration of fiber optics may play a critical role in the development of quantum information processors based on trapped ions and atoms by enabling scalable collection and delivery of light and coupling trapped ions to optical…
We present an experiment to characterize our new linear ion trap designed for the operation of a many-ion optical clock using 115-In^+ as clock ions. For the characterization of the trap as well as the sympathetic cooling of the clock ions…
A single-ion reservoir has been tested, and characterized in order to be used as a highly sensitive optical detector of electric signals arriving at the trapping electrodes. Our system consists of a single laser-cooled $^{40}$Ca$^+$ ion…
Samples of ultracold 174 Yb+ ions, confined in a linear radio-frequency Paul trap, are heated via self-induced micromotion interruption, while their temperature, density, and therefore structural phase are monitored and simulated. The…
In this work, we present the design, implementation, and construction of a linear Paul trap in a blade configuration. The trap was optimized to minimize micromotion and enable the formation of linear ion chains comprising tens of ions. We…
Active optical frequency standards provide interesting alternatives to their passive counterparts. Particularly, such a clock alone continuously generates highly-stable narrow-line laser radiation. Thus a local oscillator is not required to…
Optical lattice clocks surpass primary Cs microwave clocks in frequency stability and accuracy, and are promising candidates for a redefinition of the second in the International System of Units (SI). However, the robustness of optical…
We identify Ba$^{4+}$ (Te-like) as a promising candidate for a high-accuracy optical clock. The lowest-lying electronic states are part of a $^3P_J$ fine structure manifold with anomalous energy ordering, being non-monotonic in $J$. We…
Current state-of-the-art frequency standards are passive optical atomic clocks where the frequency of an optical resonator is stabilized to a narrow atomic transition. Passive clocks have achieved unprecedented stabilities of 6.6 x 10--19…
A transportable optical clock refer to the $4s^2S_{1/2}-3d^2D_{5/2}$ electric quadrupole transition at 729 nm of single $^{40}Ca^+$ trapped in mini Paul trap has been developed. The physical system of $^{40}Ca^+$ optical clock is…
Trapped ions are ideally suited for precision spectroscopy, as is evident from the remarkably low systematic uncertainties of single-ion clocks. The major weakness of these clocks is the long averaging time, necessitated by the low signal…