Related papers: Position sensitive SiPM detector for Cherenkov app…
The analog hadron calorimeter for the International Linear Collider (ILC) of the CALICE collaboration utilized novel silicon detectors, the Sillicon Photomultipliers (SiPMs), for the detection of scintillation light coming from very small…
High-time-resolution counters based on plastic scintillator with silicon photomultiplier (SiPM) readout have been developed for applications to high energy physics experiments for which relatively large-sized counters are required. We have…
Using thin scintillating fibers with Silicon Photomultiplier (SiPM) readout a mo dular high-resolution charged-particle tracking detector has been designed. The fiber modules consist of 2 x 5 layers of 128 round multiclad scintillating…
A mini-PET style detector system is being developed for a plant imaging application with a compact array of silicon photomultipliers (SiPM) replacing position sensitive photomultipliers (PSPMT). In addition to compactness, the use of SiPMs…
The use of silicon photomultipliers (SiPMs) alongside conventional photomultiplier tubes (PMTs) is a remarkable technological development in modern ground-based very high energy gamma-ray astronomy. SiPMs exhibit comparable or even higher…
We have developed particle detectors based on fused silica (quartz) Cherenkov radiators read out with micro-channel plate photomultipliers (MCP-PMTs) or silicon photomultipliers (SiPMs) for high precision timing (Sigma(t) about 10-15 ps).…
The Hamamatsu UV-light enhanced 64-channel SiPM array of the newest generation (S13361-3050AS-08) has been examined for the purpose of being used for the Silicon Elementary Cell Add-on (SiECA) of the EUSO-SPB balloon experiment.…
Multichip modules (MCM) with 4 single photon counting MPEC 2.3 chips bump bonded to 1.3 cm x 1.3 cm large CdTe and Si semiconductor sensors as well as to single chip pixel detectors have been successfully built and operated. The MPEC 2.3…
The use of silicon photomultipliers (SiPMs) in imaging atmospheric Cherenkov telescopes is expected to extend the observation times of very-high-energy gamma-ray sources, particularly within the highest energy domain of 50-300 TeV, where…
A novel modular high-resolution charged-particle tracking detector design using $250\mu m$ diameter, round, scintillating fibers and SiPM arrays for readout is presented. The fiber modules consist of 8 layers of 128 fibers, mechanically sta…
Particle identification at high rates is an important challenge for many current and future high-energy physics experiments. The upgrade of the COMPASS RICH-1 detector requires a new technique for Cherenkov photon detection at count rates…
The recent improvements in the performance of the silicon photomultipliers (SiPMs) made them attractive options as photo sensors of imaging atmospheric Cherenkov telescopes (IACTs). In fact, they are already adopted in some IACTs such as…
Silicon photomultipliers (SiPMs) have a few advantages over conventional photomultiplier tubes (PMTs) used in imaging atmospheric Cherenkov telescopes. The first notable characteristic is their higher photon detection efficiency (PDE) of up…
Silicon Photomultipliers (SiPMs) are state-of-the-art photon detectors used in particle physics, medical imaging, and beyond. They are sensitive to individual photons in the optical wavelength regime and achieve time resolutions of a few…
Large-area silicon photomultipliers (SiPMs) are desired in many applications where large surfaces have to be covered. For instance, a large area SiPM has been developed by Hamamatsu Photonics in collaboration with the University of Geneva,…
Gamma-ray observations in the very-high-energy domain (E > 30 GeV) can exploit the imaging of few-nanosecond Cherenkov flashes from atmospheric particle showers. Photomultipliers have been used as the primary photosensors to detect…
This work illustrates and compares some methods to measure the most relevant parameters of silicon photo-multipliers (\sipm{}s), such as photon detection efficiency as a function of over-voltage and wavelength, dark count rate, optical…
Most detector systems used for positron emission particle tracking (PEPT) are very expensive due to the use of inorganic plastic scintillators combined with a high number of readout electronic channels. This work aims to reduce the overall…
Due to their very fast signal rise time in the order of 1 ns, Silicon-Photomultipliers have become of increasing interest for many experiments that require very good timing resolution. With the prospect of an application in medical imaging…
The main challenges posed by the design of future Positron Emission Tomography machines are the improvement of the spatial and timing resolution and the combined operation with magnetic resonance. The Micro Pixel Photon Counter by Hamamatsu…