English
Related papers

Related papers: GEM-based beam profile monitors for the antiproton…

200 papers

The increase in the number of readout channels in new detectors, like the Micro Pattern Gas Detectors (MPGD), in the order of several millions, requires a large amount of electrical power to supply the front-end electronics, up to hundreds…

Instrumentation and Detectors · Physics 2024-01-18 A. Lanza , E. Romano , S. Selmi

The detection of low energy neutrinos ($<$ few tens of MeV) via coherent nuclear scattering remains a holy grail of sorts in neutrino physics. This uncontroversial mode of interaction is expected to profit from a sizeable increase in cross…

High Energy Physics - Experiment · Physics 2011-05-12 P. Barbeau , J. I. Collar , J. Miyamoto , I. Shipsey

After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high $\eta$ region. To improve both the tracking and…

Instrumentation and Detectors · Physics 2021-12-08 M. Abbas , M. Abbrescia , H. Abdalla , A. Abdelalim , S. AbuZeid , A. Agapitos , A. Ahmad , A. Ahmed , W. Ahmed , C. Aimè , C. Aruta , I. Asghar , P. Aspell , C. Avila , J. Babbar , Y. Ban , R. Band , S. Bansal , L. Benussi , V. Bhatnagar , M. Bianco , S. Bianco , K. Black , L. Borgonovi , O. Bouhali , A. Braghieri , S. Braibant , S. Butalla , S. Calzaferri , M. Caponero , J. Carlson , F. Cassese , N. Cavallo , S. S. Chauhan , S. Colafranceschi , A. Colaleo , A. Conde Garcia , M. Dalchenko , A. De Iorio , G. De Lentdecker , D. Dell Olio , G. De Robertis , W. Dharmaratna , S. Dildick , B. Dorney , R. Erbacher , F. Fabozzi , F. Fallavollita , A. Ferraro , D. Fiorina , E. Fontanesi , M. Franco , C. Galloni , P. Giacomelli , S. Gigli , J. Gilmore , M. Gola , M. Gruchala , A. Gutierrez , R. Hadjiiska , T. Hakkarainen , J. Hauser , K. Hoepfner , M. Hohlmann , H. Hoorani , T. Huang , P. Iaydjiev , A. Irshad , A. Iorio , F. Ivone , W. Jang , J. Jaramillo , A. Juodagalvis , E. Juska , B. Kailasapathy , T. Kamon , Y. Kang , P. Karchin , A. Kaur , H. Kaur , H. Keller , H. Kim , J. Kim , S. Kim , B. Ko , A. Kumar , S. Kumar , N. Lacalamita , J. S. H. Lee , A. Levin , Q. Li , F. Licciulli , L. Lista , K. Liyanage , F. Loddo , M. Luhach , M. Maggi , Y. Maghrbi , N. Majumdar , K. Malagalage , S. Malhotra , S. Martiradonna , C. McLean , J. Merlin , M. Misheva , G. Mocellin , L. Moureaux , A. Muhammad , S. Muhammad , S. Mukhopadhyay , M. Naimuddin , S. Nuzzo , R. Oliveira , P. Paolucci , I. C. Park , L. Passamonti , G. Passeggio , A. Peck , A. Pellecchia , N. Perera , L. Petre , H. Petrow , D. Piccolo , D. Pierluigi , G. Raffone , M. Rahmani , F. Ramirez , A. Ranieri , G. Rashevski , B. Regnery , M. Ressegotti , C. Riccardi , M. Rodozov , E. Romano , C. Roskas , B. Rossi , P. Rout , J. D. Ruiz , A. Russo , A. Safonov , A. K. Sahota , D. Saltzberg , G. Saviano , A. Shah , A. Sharma , R. Sharma , T. Sheokand , M. Shopova , F. M. Simone , J. Singh , U. Sonnadara , E. Starling , B. Stone , J. Sturdy , G. Sultanov , Z. Szillasi , D. Teague , D. Teyssier , T. Tuuva , M. Tytgat , I. Vai , N. Vanegas , R. Venditti , P. Verwilligen , W. Vetens , A. K. Virdi , P. Vitulo , A. Wajid , D. Wang , K. Wang , I. J. Watson , N. Wickramage , D. D. C. Wickramarathna , S. Yang , U. Yang , Y. Yang , J. Yongho , I. Yoon , Z. You , I. Yu , S. Zaleski

On-line monitoring of beam quality for high brightness beams is only possible using non-invasive instruments. For matching measurements, very few such instruments are available. One candidate is a quadrupole pick-up. Therefore, a new type…

Accelerator Physics · Physics 2009-11-07 Andreas Jansson

A new type of resistive plate chamber (RPC) is under development using thin-film resistive electrodes based on diamond-like carbon (DLC). Planned to be put on the path of high-intensity low-momentum muon beam of the MEG II experiment, this…

Instrumentation and Detectors · Physics 2022-12-21 Atsushi Oya , Kei Ieki , Atsuhiko Ochi , Rina Onda , Wataru Ootani , Kensuke Yamamoto

We present the design and initial prototype results of a pixellized proton beam profile monitor for the COMET experiment at J-PARC. The goal of COMET is to look for charged lepton flavor violation by direct muon to electron conversion at a…

Instrumentation and Detectors · Physics 2014-11-18 M. Cerv , P. Sarin , H. Pernegger , P. Vageesvaran , E. Griesmayer

A gas electron multiplier (GEM) detector with a gadolinium cathode has been developed to explore its potential application as a neutron detector. It consists of three standard-sized ($10\times 10$ cm${}^{2}$) GEM foils and a thin gadolinium…

Instrumentation and Detectors · Physics 2020-12-07 DongHyun Song , Kyungeon Choi , Youngun Jeng , Yechan Kang , Jason Sang Hun Lee , Inkyu Park , Sunyoung Yoo

The Gas Electron Multiplier (GEM) has become a widely used technology for high-rate particle physics experiments like COMPASS, LHCb and are being used as the readout system for the upcoming upgrade version of other experiments such as ALICE…

Instrumentation and Detectors · Physics 2021-05-26 Promita Roy , Purba Bhattacharya , Supratik Mukhopadhyay , Nayana Majumdar

For the International Large Detector (ILD) at the planned International Linear Collider (ILC) a Time Projection Chamber (TPC) is foreseen as the main tracking detector. To achieve the required point resolution, Micro-Pattern Gaseous…

Instrumentation and Detectors · Physics 2020-06-26 Ties Behnke , Ralf Diener , Ulrich Einhaus , Uwe Krämer , Paul Malek , Oliver Schäfer , Mengqing Wu

New Micromegas (Micro-mesh gaseous detectors) are being developed in view of the future physics projects planned by the COMPASS collaboration at CERN. Several major upgrades compared to present detectors are being studied: detectors…

Weakly Interacting Massive Particles (WIMPs) are one of the best motivated candidates to compose the Dark Matter of the Universe. The lack of experimental confirmation by direct detection experiments or collider searches has ruled out…

Instrumentation and Detectors · Physics 2025-07-04 Oscar Perez

We present the development and characterization of a compact low-energy ion beam diagnostic for the WISArD (Weak Interaction Studies with $\mathrm{^{32}Ar}$ Decay) experiment at ISOLDE/CERN. The microchannel plate (MCP) detector, which is…

A large volume time projection chamber (TPC) has been proposed as main tracking device for a detector at a future linear e+e- collider. Gas electron multipliers (GEMs) are studied as potential replacement of the conventional wire based gas…

Instrumentation and Detectors · Physics 2007-05-23 Peter Wienemann

The use of GEM foils for the amplification stage of a TPC instead of a con- ventional MWPC allows one to bypass the necessity of gating, as the backdrift is suppressed thanks to the asymmetric field configuration. This way, a novel…

In MicroPattern Gas Detectors (MPGD) when the pixel size is below 100 micron and the number of pixels is large (above 1000) it is virtually impossible to use the conventional PCB read-out approach to bring the signal charge from the…

Instrumentation and Detectors · Physics 2015-06-26 R. Bellazzini , F. Angelini , L. Baldini , F. Bitti , A. Brez , L. Latronico , M. M. Massai , M. Minuti , N. Omodei , M. Razzano , C. Sgro , G. Spandre , E. Costa , P. Soffitta

Micro-Pattern Gas Detectors (MPGDs) are extensively employed in modern high-energy and nuclear Physics experiments because of their excellent spatial resolution, high rate capability, and operational stability. Among these, the Gas Electron…

Instrumentation and Detectors · Physics 2026-05-29 Sachin Rana , Md. Kaosor Ali Mondal , Poojan Angiras , Amal Sarkar

Low-Gain Avalanche Detectors (LGADs) are a type of thin silicon detector with a highly doped gain layer that provides moderate internal signal amplification. One recent challenge in the use of LGADs, studied by several research groups, is…

Instrumentation and Detectors · Physics 2024-05-07 S. Braun , Q. Buat , J. Ding , P. Kammel , S. M. Mazza , F. McKinney-Martinez , A. Molnar , C. Lansdell , J. Ott , A. Seiden , B. Schumm , Y. Zhao

A Time Projection Chamber (TPC) is a powerful detector for 3-dimensional tracking and particle identification for ultra-high multiplicity events. It is the central tracking device of many experiments, e.g. the ALICE experiment at CERN. The…

Instrumentation and Detectors · Physics 2019-08-14 Bernhard Ketzer

To extend the acceptance of the CMS muon spectrometer to the region 2.4 $<|\eta|<$ 2.8, stacks of triple-GEM chambers, forming the ME0 station, are planned for the CMS Phase 2 Upgrade. These large-area micro-pattern gaseous detectors must…

Increasing the luminosity of relativistic hadron beams is critical for the advancement of nuclear physics. Coherent electron cooling (CEC) promises to cool such beams significantly faster than alternative methods. We present simulations of…