Related papers: Absolute luminosity measurements with the LHCb det…
Measuring cross-sections at the LHC requires the luminosity to be determined accurately at each centre-of-mass energy $\sqrt{s}$. In this paper results are reported from the luminosity calibrations carried out at the LHC interaction point 8…
The high resolution of the LHCb vertex detector makes it possible to perform precise measurements of the vertex positions of beam-gas and beam-beam interactions. With these measurements beam parameters such as width and position can be…
A precision luminosity measurement is essential for LHC cross-section measurements to determine fundamental parameters of the standard model and constrain or discover beyond-the-standard-model phenomena. The luminosity of the CMS detector…
The high resolution of the LHCb vertex detector makes it possible to perform precise measurements of vertices of beam-gas and beam-beam interactions and allows beam parameters such as positions, angles and widths to be determined. Using the…
Precision luminosity measurements are essential to determine the fundamental properties of the physics processes at the LHC. The estimation of the integrated luminosity at the CMS experiment requires absolute scale calibration of the…
An absolute luminosity can be measured in an accelerator by sweeping beams transversely across each other in the so called van der Meer scan. We prove that the method can be applied in the general case of arbitrary beam directions and a…
The measurement of the luminosity recorded by the CMS detector installed at LHC interaction point 5, using proton-proton collisions at $\sqrt{s} =$ 13 TeV in 2015 and 2016, is reported. The absolute luminosity scale is measured for…
This is the first of the series of papers which present a precision method of the day-by-day monitoring of the absolute LHC luminosity. The method is based on the measurement of the rate of coplanar lepton pairs produced in peripheral…
The main method for calibrating the luminosity at Large Hadron Collider (LHC) is van der Meer scan where the beams are swept transversely across each other. This beautiful method was invented in 1968. Despite the honourable age, it remains…
Measurements of luminosity obtained using the ATLAS detector during early running of the Large Hadron Collider (LHC) at sqrt(s) = 7 TeV are presented. The luminosity is independently determined using several detectors and multiple…
Absolute normalisation of the LHC measurements with O(1%) precision and their relative normalisation, for the data collected at variable centre-of-mass energies, or for variable beam particle species, with O(0.1%) precision is crucial for…
The luminosity determination for the ATLAS detector at the LHC during Run 2 is presented, with $pp$ collisions at $\sqrt{s}=13$ TeV. The absolute luminosity scale is determined using van der Meer beam separation scans during dedicated…
Absolute normalisation of the LHC measurements with a precision of O(1%) is desirable but beyond the reach of the present LHC detectors. This series of papers proposes and evaluates a measurement method capable to achieve such a precision…
The application of the two-photon process pp -> pp + mu^+mu^- for the luminosity measurements at LHC with the ATLAS detector is considered. The expected accuracy of the absolute offline luminosity determination is 1 - 2 % for the luminosity…
In this paper it is shown that a measurement of the relative luminosity changes at the LHC may be obtained by analysing the currents drawn from the high voltage power supplies of the electromagnetic section of the forward calorimeter of the…
In order to estimate in absolute terms the luminosity of LHC certain beam parameters have to be measured very accurately. In particular the total beam current and the relative distribution of the charges around the ring, the transverse size…
At the Large Hadron Collider (LHC), absolute luminosity calibrations obtained by the van der Meer (vdM) method are affected by the mutual electromagnetic interaction of the two beams. The colliding bunches experience relative orbit shifts,…
The LHCb detector optimised its performance in Runs~1 and~2 by stabilising the instantaneous luminosity during a fill. This was achieved by tuning the distance between the two colliding beams according to the measurement of instantaneous…
By extracting the beam with a bent crystal or by using an internal gas target, the multi-TeV proton and lead LHC beams allow one to perform the most energetic fixed-target experiments ever and to study $pp$, $p$d and $p$A collisions at…
A network of Timepix (TPX) devices installed in the ATLAS cavern measures the LHC luminosity as a function of time as a stand-alone system. The data were recorded from 13 TeV proton-proton collisions in 2015. Using two TPX devices, the…