Sensitive probing of temperature variations on nanometer scales represents an outstanding challenge in many areas of modern science and technology. In particular, a thermometer capable of sub-degree temperature resolution as well as…
The design and operation of a homemade low cost vibrating sample magnetometer is described here. The sensitivity of this instrument is better than 10-2 emu and found to be very efficient for the measurement of magnetization of most of the…
We describe a heat capacity measurement system for the study of the field-orientation dependence for temperatures down to 50 mK. A "Vector Magnet" combined with a mechanical rotator for the dewar enables the rotation of the magnetic field…
We develop a nonperturbative technique in field theory to study properties of infinite nuclear matter at zero temperature as well as at finite temperatures. Here we dress the nuclear matter with off-mass shell pions. The techniques of…
Thermal equilibrium states are exponentially hard to distinguish at very low temperatures, making equilibrium quantum thermometry in this regime a formidable task. We present a thermometric scheme that circumvents this limitation, by using…
In-vacuo cryogenic environments are ideal for applications requiring both low temperatures and extremely low particle densities. This enables reaching long storage and coherence times for example in ion traps, essential requirements for…
We describe a new table-top electrostatic storage ring concept for $30$ keV polarized ions at frozen spin condition. The device will ultimately be capable of measuring magnetic fields with a resolution of 10$^{-21}$ T with sub-mHz…
High pressure Nuclear Magnetic Resonance (NMR) is known to uncover behavior of matter at extreme conditions. However, significant maintenance demands, space requirements and high costs of superconducting magnets render its application…
We experimentally demonstrate a method to determine the temperature of trapped ions which is suitable for monitoring fast thermalization processes. We show that observing and analyzing the lineshape of dark resonances in the fluorescence…
We demonstrate a novel atom chip trapping system that allows the placement and high-resolution imaging of ultracold atoms within microns from any <100 um-thin, UHV-compatible material, while also allowing sample exchange with minimal…
Fast feedback from cryogenic electrical characterization measurements is key for the development of scalable quantum computing technology. At room temperature, high-throughput device testing is accomplished with a probe-based solution,…
One of the daunting challenges in modern low temperature scanning tunneling microscopy (STM) is the difficulty of combining atomic resolution with cryogen free cooling. Further functionality needs, such as ultra-high vacuum (UHV), high…
We report the design and development of a piezoelectric sample rotation system, and its integration into an Oxford Instruments Kelvinox 100 dilution refrigerator, for orientation-dependent studies of quantum transport in semiconductor…
Non-contact temperature sensors are widely used, often utilizing infrared light for temperature measurement. However, specific applications demand non-contact detection, particularly within closed containers containing fluids or gases,…
We present an experimental setup and methodology designed to facilitate high-precision thermal measurements required for infrared medical tomography. The approach which is best suited for the study of specialized hardware phantoms comprises…
Lutetium thermometry has been used to analyze Oklo natural nuclear reactor zones but leads to widely varying and puzzling predictions for the temperatures $T_O$ which in turn impacts bounds on time variation of the fine structure constant…
We show that temperature of a current (I = 20 mA) carrying manganite (Nd0.5Ca0.5Mn0.93Ni0.07O3) in presence of a magnetic field (H) decreases abruptly as much as deltaT = 45 K (7 K) accompanied by a step like decrease in magnetoresistance…
The implementation of a scanning microscope capable of working in confocal, atomic force and apertureless near field configurations is presented. The microscope is designed to operate in the temperature range 4 - 300 K, using conventional…
A magnetic coil operated at cryogenic temperatures is used to produce spatial, relative field gradients below 6 ppm/cm, stable for several hours. The apparatus is a prototype of the magnetic components for a neutron electric dipole moment…
Many thermal measurements in high magnetic fields require thermometers that are sensitive over a wide temperature range, are low mass, have a rapid thermal response, and have a minimal, easily correctable magnetoresistance. Here we report…