English
Related papers

Related papers: Compact Frequency Standard Based on an Intra-cavit…

200 papers

Frequency metrology is a cornerstone of modern precision measurements and optical atomic clocks have emerged as the most precise measurement devices. In this progress report, we explore various Ramsey interrogation schemes tailored to…

Quantum Physics · Physics 2026-03-30 Timm Kielinski , Klemens Hammerer

We studied noise properties of microwave signals transmitted through the cryogenic resonator. The experiments were performed with the 11.342 GHz sapphire loaded cavity resonator cooled to 6.2 K. Based on the measured transmission…

Instrumentation and Detectors · Physics 2021-02-23 Eugene Ivanov , Michael Tobar

One of the major limitations of atomic gravimeters is represented by the vibration noise of the measurement platform, which cannot be distinguished from the relevant acceleration signal. We demonstrate a new method to perform an atom…

Atomic Physics · Physics 2019-06-05 G. D'Amico , L. Cacciapuoti , M. Jain , S. Zhan , G. Rosi

We consider a system consisting of an atom in the approximation of a harmonic oscillator of frequency $\bar{\omega}$, coupled to the scalar potential inside a spherical reflecting cavity of radius R. We use {\it dressed} states introduced…

Atomic Physics · Physics 2009-11-07 G. Flores-Hidalgo , A. P. C. Malbouisson , Y. W. Milla

We demonstrate, for the first time, Ramsey CPT spectroscopy with a miniature electro-optical bench associated to a dual-frequency generator based on combined optical injection locking and optical phase locking techniques Preliminary results…

Atomic beams are powerful tools for measuring spin coherence in hot vapors but require bulky setups, limiting device miniaturization. We demonstrate that micron-thin vapor cells can mimic atomic beam behavior by exploiting…

Quantum Physics · Physics 2025-06-18 Mark Dikopoltsev , Eliran Talker , Yefim Barash , Noa Mazurski , Uriel Levy

We trap a single cesium atom in a standing-wave optical dipole trap. Special experimental procedures, designed to work with single atoms, are used to measure the oscillation frequency and the atomic energy distribution in the dipole trap.…

Quantum Physics · Physics 2009-11-07 Wolfgang Alt , Dominik Schrader , Stefan Kuhr , Martin Mueller , Victor Gomer , Dieter Meschede

We perform Ramsey-Bord\'e spectroscopy on laser-cooled magnesium atoms in free fall to measure the 1S0 \rightarrow 3P1 intercombination transition frequency. The measured value of 655 659 923 839 730 (48) Hz is consistent with our former…

Single Cesium atoms are cooled and trapped inside a small optical cavity by way of a novel far-off-resonance dipole-force trap (FORT), with observed lifetimes of 2 to 3 seconds. Trapped atoms are observed continuously via transmission of a…

Quantum Physics · Physics 2009-11-07 J. McKeever , J. R. Buck , A. D. Boozer , A. Kuzmich , H. -C. Naegerl , D. M. Stamper-Kurn , H. J. Kimble

We demonstrate an easy to manufacture, 25 mm long ultra-stable optical reference cavity for transportable photonic microwave generation systems. Employing a rigid holding geometry that is first-order insensitive to the squeezing force and a…

Instrumentation and Detectors · Physics 2017-08-02 J. Davila-Rodriguez , F. N. Baynes , A. D. Ludlow , T. M. Fortier , H. Leopardi , S. A. Diddams , F. Quinlan

In recent years the interest in studying interactions of Rydberg atoms or ensembles thereof with optical and microwave frequency fields has steadily increased, both in the context of basic research and for potential applications in quantum…

Quantum Physics · Physics 2017-05-31 M. Stammeier , S. Garcia , T. Thiele , J. Deiglmayr , J. A. Agner , H. Schmutz , F. Merkt , A. Wallraff

The astrophysical reach of current and future ground-based gravitational-wave detectors is mostly limited by quantum noise, induced by vacuum fluctuations entering the detector output port. The replacement of this ordinary vacuum field with…

Amplification is usually necessary when measuring the frequency instability of microwave signals. In this work, we develop a flicker noise free frequency measurement system based on a common or shared amplifier. First, we show that…

Instrumentation and Detectors · Physics 2012-02-23 Daniel L. Creedon , Michael E. Tobar , Eugene N. Ivanov , John G. Hartnett

Cold-atom magnetometers can achieve an exceptional combination of superior sensitivity and high spatial resolution. One key challenge these quantum sensors face is improving the sensitivity within a given timeframe while preserving a high…

Quantum Physics · Physics 2025-03-04 Zhu Ma , Chengyin Han , Zhi Tan , Haihua He , Shenszhen Shi , Xin Kang , Jiatao Wu , Jiahao Huang , Bo Lu , Chaohong Lee

We study in detail the mechanisms causing dephasing of hyperfine coherences of cesium atoms confined by a far off-resonant standing wave optical dipole trap [S. Kuhr et al., Phys. Rev. Lett. 91, 213002 (2003)]. Using Ramsey spectroscopy and…

Quantum Physics · Physics 2007-05-23 S. Kuhr , W. Alt , D. Schrader , I. Dotsenko , Y. Miroshnychenko , A. Rauschenbeutel , D. Meschede

In quantum metrology and quantum simulation, a coherent non-classical state must be manipulated before unwanted interactions with the environment lead to decoherence. In atom interferometry, the non-classical state is a spatial…

Atomic Physics · Physics 2024-08-19 Cristian D. Panda , Matthew Tao , James Egelhoff , Miguel Ceja , Victoria Xu , Holger Müller

We demonstrate a new feedback algorithm to cool a single neutral atom trapped inside a standing-wave optical cavity. The algorithm is based on parametric modulation of the confining potential at twice the natural oscillation frequency of…

Quantum Physics · Physics 2018-05-23 C. Sames , C. Hamsen , H. Chibani , P. A. Altin , T. Wilk , G. Rempe

Cold atoms from a magneto-optic trap have been used as a nonlinear medium in a nearly resonant cavity. Squeezing in a probe beam passing through the cavity was demonstrated. The measured noise reduction is 40% for free atoms and 20% for…

Quantum Physics · Physics 2009-10-31 A. Lambrecht , T. Coudreau , A. M. Steinberg , E. Giacobino

We demonstrate a high-performance coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique (PPOP) in the pulsed regime, allowing the detection of high-contrast and narrow Ramsey-CPT…

We present a compact atomic clock interrogating ultracold 87Rb magnetically trapped on an atom chip. Very long coherence times sustained by spin self-rephasing allow us to interrogate the atomic transition with 85% contrast at 5 s Ramsey…

Atomic Physics · Physics 2015-07-14 Ramon Szmuk , Vincent Dugrain , Wilfried Maineult , Jakob Reichel , Peter Rosenbusch
‹ Prev 1 4 5 6 7 8 10 Next ›