Related papers: The ICARUS Front-end Preamplifier Working at Liqui…
Optical readout of large scale dual-phase liquid Argon TPCs is an attractive alternative to charge readout and has been successfully demonstrated on a 2x2m active region within the CERN protoDUNE cold box. ARIADNE+ uses four Timepix3…
The Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU is designed to reduce the particle background of the instrument and to enable the mission science goals. It is a 4 pixel silicon microcalorimeter sensed by an Ir/Au TES…
ALFE2 is an ATLAS Liquid Argon Calorimeter (LAr) Front-End ASIC designed for the HL-LHC upgrade. ALFE2 comprises four channels of pre-amplifiers and CR-(RC)2 shapers with adjustable input impedance. ALFE2 features two separate gain outputs…
We report on a systematic characterization of microbulk Micromegas readouts in high-pressure Ar+1%iC4H10 and Ne+2%iC4H10 mixtures. Experimental data on gain, electron transmission and energy resolution are presented for a wide range of…
The High Luminosity upgrade of the Large Hadron Collider (HL-LHC) at CERN will include eight cryo-assemblies that are expected to be fabricated and delivered to CERN by the US HL-LHC Accelerator Upgrade Project (AUP) as part of the U.S.…
The Liquid Argon Purity Demonstrator was an R&D test stand designed to determine if electron drift lifetimes adequate for large neutrino detectors could be achieved without first evacuating the cryostat. We describe here the cryogenic…
The ARIANNA concept utilizes the Ross Ice Shelf near the coast of Antarctica to increase the sensitivity to cosmogenic neutrinos by roughly an order of magnitude when compared to the sensitivity of existing detectors and those under…
We report first results obtained during the commissioning of the Laser Resonance Chromatography (LRC) apparatus, which is conceived to enable atomic structure investigations in the region of the heaviest elements beyond nobelium. In our…
The DarkSide-50 experiment at the Laboratori Nazionali del Gran Sasso is a search for dark matter using a dual phase time projection chamber with 50 kg of low radioactivity argon as target. Light signals from interactions in the argon are…
Common-mode choke inductors are useful tools for resolving grounding issues in large detector systems. Using inductive components on cryogenic pre-amplifier boards has so far been prevented by the poor low-temperature performance of common…
The exquisite capabilities of liquid Argon Time Projection Chambers make them ideal to search for weakly interacting particles in Beyond the Standard Model scenarios. Given their location at CERN the ProtoDUNE detectors may be exposed to a…
New neutrino-nucleus interaction cross-section measurements are required to improve nuclear models sufficiently for future long-baseline neutrino experiments to meet their sensitivity goals. A time projection chamber (TPC) filled with a…
Ultra high energy neutrinos may be observed in ice by the emission of acoustic signals. The SPATS detector has investigated the possibility of observing GZK-neutrinos in the clear ice near the South Pole at the IceCube detector site. To…
IceCube is a km^3 scale neutrino detector being constructed deep in the Antarctic ice. When complete, IceCube will consist of 4800 optical modules deployed on 80 strings between 1450 and 2450 m of depth. During the 2007-2008 data taking…
As noble liquid time projection chambers grow in size their high voltage requirements increase, and detailed, reproducible studies of dielectric breakdown and the onset of electroluminescence are needed to inform their design. The Xenon…
An upgrade of the Near Detector of the T2K long baseline neutrino oscillation experiment, ND280, has been proposed. This upgrade will include two new Time Projection Chambers, each equipped with 16 resistive MicroMegas modules for gas…
We report on the measurement of the specific activity of Ar-39 in natural argon. The measurement was performed with a 2.3-liter two-phase (liquid and gas) argon drift chamber. The detector was developed by the WARP Collaboration as a…
The ATLAS muon spectrometer uses drift-tube chambers for precision tracking. The performance of these chambers in the presence of magnetic field and high radiation fluxes is studied in this article using test-beam data recorded in the Gamma…
We present the measurement of $\pi^{+}$--argon inelastic cross sections using the ProtoDUNE Single-Phase liquid argon time projection chamber in the incident $\pi^+$ kinetic energy range of 500 -- 800 MeV in multiple exclusive channels…
We describe the flight performance of the cryogenic system of the infrared astronomical satellite AKARI, which was successfully launched on 2006 February 21 (UT). AKARI carries a 68.5 cm telescope together with two focal plane instruments,…