A system for bunch-by-bunch detection of transverse proton and antiproton coherent oscillations in the Tevatron is described. It is based on the signal from a single beam-position monitor located in a region of the ring with large amplitude…

Accelerator Physics · Physics 2015-03-19 Giulio Stancari , Alexander Valishev

The measurement of the longitudinal behavior of the accelerated particle beams at Fermilab is crucial to the optimization and control of the beam and the maximizing of the integrated luminosity for the particle physics experiments.…

Instrumentation and Detectors · Physics 2011-10-19 R. Thurman-Keup , C. Bhat , W. Blokland , J. Crisp , N. Eddy , B. Fellenz , R. Flora , A. Hahn , S. Hansen , T. Kiper , A. Para , S. Pordes , A. V. Tollestrup

A system for bunch-by-bunch detection of transverse proton and antiproton coherent oscillations in the Fermilab Tevatron collider is described. It is based on the signal from a single beam-position monitor located in a region of the ring…

Accelerator Physics · Physics 2013-12-19 G. Stancari , A. Valishev , S. M. White

To understand and control the dynamics in the longitudinal phase space, time-resolved measurements of different bunch parameters are required. For a reconstruction of this phase space, the detector systems have to be synchronized. This…

On-line monitoring of beam quality for high brightness beams is only possible using non-invasive instruments. For matching measurements, very few such instruments are available. One candidate is a quadrupole pick-up. Therefore, a new type…

Accelerator Physics · Physics 2009-11-07 Andreas Jansson

The performance of the LHC depends critically on the accurate measurements of the betatron tunes. The betatron tune values of each LHC beam may be measured without excitation using a newly installed transverse Schottky monitor. A high-level…

Accelerator Physics · Physics 2012-08-14 J. Cai , E. McCrory , R. Pasquinelli , M. Favier , O. R. Jones , T. Lahey , A. Jansson

This study introduces a novel real-time betatron tune measurement algorithm, utilizing Schottky signals and an FPGA-based backend architecture, specifically designed for rapidly ramping synchrotrons, with particular application to the…

Accelerator Physics · Physics 2025-06-11 Peihan Sun , Manzhou Zhang , Renxian Yuan , Deming Li , Jian Dong , Ying Shi

Non-destructive Schottky detectors are indispensable devices widely used in experiments at heavy-ion storage rings. In particular, they can be used to accurately determine the masses and lifetimes of short-lived exotic nuclear species.…

Betatron tune measurement is essential for beam control in compact proton-therapy synchrotrons, yet conventional peak-detection techniques are not robust under the low signal-to-noise ratio (SNR) conditions typical of these machines. This…

Accelerator Physics · Physics 2025-12-11 Peihan Sun , Manzhou Zhang , Renxian Yuan , Deming Li , Jian Dong , Ying Shi

The LHC Schottky system consists for four independent 4.8 GHz triple down conversion receivers with associated data acquisition systems. Each system is capable of measuring tune, chromaticity, momentum spread in either horizontal or…

Accelerator Physics · Physics 2012-09-07 Ralph J. Pasquinelli , Andreas Jansson , O. Rhodri Jones , Fritz Caspers

A system was developed for bunch-by-bunch detection of transverse proton and antiproton coherent oscillations based on the signal from a single beam-position monitor (BPM) located in a region of the ring with large amplitude functions. The…

Accelerator Physics · Physics 2012-02-02 G. Stancari , A. Valishev , A. Semenov

Synchrotron radiation has been used for many years as a beam diagnostic at electron accelerators. It is not normally associated with proton accelerators as the intensity of the radiation is too weak to make detection practical. However, if…

Instrumentation and Detectors · Physics 2011-10-17 R. Thurman-Keup , H. W. K. Cheung , A. Hahn , P. Hurh , E. Lorman , C. Lundberg , T. Meyer , D. Miller , S. Pordes , A. Valishev

The longitudinal Schottky spectra of a radio-frequency (RF) bunched and electron cooled 22Ne10+ ion beam at 70 MeV/u have been studied by a newly installed resonant Schottky pick-up at the experimental cooler storage ring (CSRe), at IMP.…

The high peak current required in free-electron lasers (FELs) is realized by longitudinal compression of the electron bunches to sub-picosecond length. In this paper, a frequency-domain diagnostic method is described that is capable of…

Instrumentation and Detectors · Physics 2012-01-31 S. Wesch , B. Schmidt , C. Behrens , H. Delsim-Hashemi , P. Schmüser

Dedicated optics with extremely short electron bunches enable synchrotron light sources to generate intense coherent THz radiation. The high degree of spatial compression in this so-called low-alpha optics entails a complex longitudinal…

Real-time, bunch-by-bunch monitoring of transverse position, longitudinal phase, and bunch length is crucial for beam control in diffraction-limited storage rings, where complex collective dynamics pose unprecedented diagnostic challenges.…

Accelerator Physics · Physics 2026-01-28 Can Liu , Xing Yang , Youming Deng , Qingqing Duan , Yongbin Leng

Precise diagnostic on the electron beam parameters is a very valuable tool and essential in the operation of synchrotron light sources. One possible option is to employ the emitted synchrotron radiation for non-destructive measurements. A…

Accelerator Physics · Physics 2025-12-08 Miriam Brosi , Johann Schmand , Jonas Breunlin , Francesca Curbis

Commissioning at the SCRF accelerator at the Fermilab Accelerator Science and Technology (FAST) Facility has included the implementation of a versatile bunch-length monitor located after the 4-dipole chicane bunch compressor for electron…

Accelerator Physics · Physics 2017-12-29 A. H. Lumpkin , R. Thurman-Keup , D. Edstrom , J. Ruan , J. Santucci

The real-time power monitoring of gyrotron is one of the key issues in the operation of electron cyclotron resonance heating system. The detector can be used for real-time power monitoring. We analyzed the principle of diode detection and…

Instrumentation and Detectors · Physics 2020-09-29 Weiye Xu , Handong Xu , Fukun Liu , Xiaojie Wang