Related papers: Locking Local Oscillator Phase to the Atomic Phase…
We experimentally demonstrated that the stability of an atomic clock improves at fastest rate $\tau^{-1}$ (where $\tau$ is the averaging time) when the phase of a local oscillator is genuinely compared to the continuous phase of many atoms…
Quantum projection noise will soon limit the best achievable precision of optical atomic clocks based on lattice-confined neutral atoms. Squeezing the collective atomic pseudo-spin via measurement of the clock state populations during…
Improving the clock stability is of fundamental importance for the development of quantum-enhanced metrology. One of the main limitations arises from the randomly-fluctuating local oscillator (LO) frequency, which introduces "phase slips"…
Atomic projection noise limits the ultimate precision of all atomic sensors, including clocks, inertial sensors, magnetometers, etc. The independent quantum collapse of $N$ atoms into a definite state (for example spin up or down) leads to…
By Faraday-rotation fluctuation spectroscopy one measures the spin noise via Faraday-induced fluctuations of the polarization plane of a laser transmitting the sample. In the fist part of this paper, we present a theoretical model of recent…
We present a novel and simple method of stabilizing the laser phase and frequency by polarization spectroscopy of an atomic vapor. In analogy to the Pound-Drever-Hall method, which uses a cavity as a memory of the laser phase, this method…
We describe a method to stabilize the amplitude of the interrogating microwave field in compact atomic clocks working in a Ramsey approach. In this technique, we take advantage of the pulsed regime to use the atoms themselves as microwave…
This paper describes the Light-Shift Laser-Lock (LSLL) technique, a novel method intended for compact atomic clocks that greatly simplifies the laser setup by stabilizing the pumping-laser frequency to the atoms involved in the clock,…
The frequency stability achieved by an optical atomic clock ultimately depends on the coherence of its local oscillator. Even the best ultrastable lasers only allow interrogation times of a few seconds, at present. Here we present a…
Laser decoherence limits the stability of optical clocks by broadening the observable resonance linewidths and adding noise during the dead time between clock probes. Correlation spectroscopy avoids these limitations by measuring correlated…
We herein report a simultaneous frequency stabilization of two 780-nm external cavity diode lasers using a precision wavelength meter (WLM). The laser lock performance is characterized by the Allan deviation measurement in which we find…
In this paper, we demonstrate a simple scheme of 6.835 GHz microwave frequency synthesizer based on the sub-sampling phase lock loop (PLL) technique. The application of the sub-sampling PLL is the key to simplify the architecture of the…
A crucial challenge to the ongoing endeavor of spaceborne gravitational wave (GW) detection resides in the laser phase noise, typically 7 to 8 orders of magnitude above the inevitable noise. The arm locking technique was proposed to…
Non-contact scanning probe microscopy (SPM) has developed into a powerful technique to image many different properties of samples. The conventional method involves monitoring the amplitude, phase or frequency of a cantilever oscillating at…
We evaluate the performance and phase diffusion of trapped $^{87}$Rb atoms in an atom-chip sensor with Ramsey interferometry and Hahn's spin echo in the time and phase domains. We trace out how the phase uncertainty of interference fringes…
The sensitivity of an atomic interferometer increases when the phase evolution of its quantum superposition state is measured over a longer interrogation interval. In practice, a limit is set by the measurement process, which returns not…
We report on the realization of an optical phase noise cancellation technique by passively embedding the optical phase information into a radio frequency (RF) signal and shifting the optical frequency with the amount of phase noise…
A simulation of an atomic force microscope operating in the constant amplitude dynamic mode is described. The implementation mimics the electronics of a real setup including a digital phase-locked loop (PLL). The PLL is not only used as a…
A weak continuous quantum measurement of an atomic spin ensemble can be implemented via Faraday rotation of an off-resonance probe beam, and may be used to create and probe nonclassical spin states and dynamics. We show that the probe light…
We demonstrate a new method of light phase shift measurement using a high-finesse optical ring cavity which exhibits reduced phase noise due to cavity length fluctuations. Two laser beams with a frequency difference of one cavity free…